Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and as directed. |
| 2 | Excavating in post holes(or similar holes ) each n.exc. 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth round in layers n.exc. 25 cm in hard/dense soil complete all as specified & as directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil etc complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth not exceeding 1.5m and getting out in hard / dense soil complete all as specified and as directed. |
| 5 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth exceeding 1.5m but not exceeding 3.0m and getting out in hard / dense soil complete all as specified and as directed. |
| 6 | Removal of excavated material [Soil] to a distance exceeding 250 m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 7 | Material and labour for cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 8 | Material and labour for cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 9 | Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 10 | Material and labour broken stone or boulders hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 11 | Material and labour Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 12 | Material and labourfor 100mm thick cement concrete 1:4:8 type D2 (40mm graded aggreded) as in sub base, finish the surface even and rough to receive topping layercomplete all as specified and as directed. |
| 13 | Material and labourfor 75mm thick cement concrete 1:3:6 type C2 (40mm graded aggreded) as in sub base, finish the surface even and rough to receive topping layercomplete all as specified and as directed. |
| 14 | Material and labour pre polished, precast Chequered cement concrete tiles of size 250mmx250mm of 22mm thick as in floors set , jointed & pointed with neat cement slurrywith white cement and pigmentincluding15 mm thick screed bedor bedding layer incementmortar (1:6) complete all as specified and as directed. |
| 15 | Material & Labour for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth without using extra cement and providing necessary joints 12mm wide to the full depth of PCC at every 3 meters and every change of directions and the joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed. |
| 16 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated trapezoidal profie sheet steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 17 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 18 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed . |
| 19 | S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [Plain & Chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment including fixed with Nut and Bolt / welding complete all as specified and as directed. |
| 20 | S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Main and Cross Beams, Hip and Jack Rafters, Purlins where connected to common rafters, and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified and as directed. |
| 21 | Material and labour for preparation of new steel surfaces to receive painting over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 22 | Supply and fixing Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 23 | Material and labour forpreparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed. |
| 24 | Supply and fixing for 30mm thick factory made flush door shutters solid core construction with block board core and ply wood face panels commercial type on both faces complete all as specified and as directed. |
| 25 | S & F Factory made, 30mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed. |
| 26 | Supply and fixing 30 mm thick, 2nd class hard wood glazed and skeleton window shutters open rebated and prepared to receive glass, guage etc (without sash bars ), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR Part I section 8 clasue 8.24(a) complete all as specified and as directed. |
| 27 | Supply and fixing 3mm thick sheet Glass ordinary quality in squares not exceeding 0.5 Sq.m and glazing with oil putty in each pane complete all as specified and as directed. |
| 28 | Supply and fixing Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long complete all as specified and as directed. |
| 29 | Supply and fixing Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 30 | Supply and fixing stainless steel butt hinge, 100mm long, medium weight, cold rolledfixed with steel screws complete all as specified and as directed. |
| 31 | Supply and fixing aluminium anodizedhandles 150mm long extruded, cast typecomplete all as specified and directed. |
| 32 | Supply and fixing 4 mm thick,Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and as directed. |
| 33 | Material and labour for 40mm thick damp proof course in cement concrete 1:2:4 type B0 (12.5mm graded aggreded) to horizontal/vertical surfaces including necessary formwork complete all as specified and as directed. |
| 34 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 35 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 36 | Material and labour for Plain cement concrete Type B1 [Nominal Mix] 1:3:6 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed. |
| 37 | Material and labour for Plain cement concrete Type B1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed. |
| 38 | Material and labour for walling of random rubble,uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6 )complete all as specified and as directed |
| 39 | Extra over granite or trap stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courseswith maximum depression on face from straight edge held against the dressed surface n exc. 20mmcomplete all as specified and as directed. |
| 40 | Material and labour for raised pointing in CM 1:4 to random or polygonal rubble,uncoursed or brought upto courses complete all as specified and as directed. |
| 41 | Materials and labour for Precast PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in bond stone set in cement mortar 1:4 complete all as specified and as directed. |
| 42 | Supply and laying 75mm bore PVC [SWR] pipesin single piece without joint as weep hole in retaining wall complete all as specified and as directed. |
| 43 | Material & Labour for Hand packing (any thickness) of broken stone or boulder at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed. |
| 44 | Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LS) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LS) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessoriesand PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth. |
| 45 | All as per item No 44 above but for 3 pin 5 Amp socket outlet point controlled by one switch socket outlet on independent board complete all as specified and as directed. |
| 46 | All as per item No 44 above but with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 markedfor 3 pin, 15 Amp switch socket outlet, independent board, including FRLSH PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly. |
| 47 | Supply & fixing Switch socket combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal controlled by one switch flush type complete all as specified and directed. |
| 48 | Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal controlled by one switch flush type complete all as specified and directed. |
| 49 | Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 65mm x 25mm,ISI marked three terminals complete all as specified and directed. |
| 50 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified and directed. |
| 51 | Supply & Fixing Surface & wall mounted Energy efficient LED Tube Light Fitting of 20 watt, 4 feet long,5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mmcomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 52 | Supply & Fixing Energy efficient & Long life Building Security Light Luminaire, of 35 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mmcomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 53 | Supply and fixing Integrated LED Bulk head with luminaire of 10W, 6000 K with Pressure Die Cast Aluminium Housing, IP54 protection, heat resistant glass cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 54 | Supply and fixing of MCB DB SPN 4 ways, powder coated, double door, 230 Volts,including bus bar neutral link, earth bar and din rail,for fixing MCB of various rating complete all as specified and as directed. |
| 55 | Supply & Fixing of MCB SP of capacity 6-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 56 | Supply & Fixing of MCB SPN of capacity 32 Amps,240 V, 10 KA \"C\" curve complete all as specified and as directed.Note for serial Item No. 54 to 56: MCB and MCB DB shall be of same make as approved by AGE (I). |
| 57 | Material & Labour for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.50 sqmm as earth lead and connected to earth dolly complete all as specified as directed. Note : (i) 3 Runs of 2.50 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length. |
| 58 | S & F Single Pointed Air Termination Copper Rod 12 mm dia and 300 mm long, fixed on base plate made of PVC including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed. |
| 59 | S & F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed. |
| 60 | Material & Labour for Earth continuity conductor or main earthing leadAluminium strip 25x3.15mm, laid in pipe/fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint complete all as specified as directed. |
| 61 | Material & Labour for Earth continuity conductor or main earthing leadcopper strip 20x3.15mm, laid in pipe/fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint complete all as specified & directed. |
| 62 | Material & Labour for making fire fighting shed with following provision and cost of the same shall have deemed to be included in unit quoted rate :-(i) GI pipe medium grade of 40MM dia -10 Rm(ii) 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated trapezoidal profie sheet steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction -05 Sqm(iii) MS Sand bucket of capacity 10Ltrs alongwith 02 Nos. of suitable size of hooks.(iv) Excavation in earth work, returning filling and removal of excavated soil, PCC foundation of suitable size for fixing of pipes.(v) Writting of \"Fire\" in white paint on sheet.(vi) cost for all fabrication work i.e cutting, weilding, nut & bolts have deemed to be included in unit quoted rate. |
| 63 | Supply and fixing of Fire extinguiser, ABC type, 9/10 Kg as per IS:15683:2018 (latest amendment), powder Based (as per IS 4308), N2 Based (stored pressure), Low pressure extinguiser (Service pressure < 19 bar ), welded low carbon steel cylinder (as per clause 9.2.5 of IS 15683), Operating temparature (°C): -30°C complete all as specified as directed by Engineer-in-Charge. |
| 64 | Supply and fixing Fire Extinguiser, Foam Type, 9 ltr as per IS: 15683: 2018 (Latest amendments),Foam Based (as per IS 4989), N2 Based (Stored Pressure),Low Pressure Extinguisher (Service Pressure ≤19 bar),Welded low carbon steel cylinders (as per Clause 9.2.5 of IS 15683), Operating Temperature (°C) : +5°C to 60°C,Test Pressure ≥ 35 bar complete all as specified as directed by Engineer-in-Charge. |
| 65 | Supply and fixing Fire Extinguiser, Dry CO2 Type, 2 kg , as per IS: 15683: 2018 (Latest amendments),Carbon Dioxide Based (as per IS 15222), CO2 Extinguishing Medium,High Pressure Extinguisher (Service Pressure >19 bar),Welded low carbon steel cylinders (as per Clause 9.2.5 of IS 15683) complete all as specified as directed by Engineer-in-Charge. |
| 66 | Supply, installation,testing and commissioning of silent Diesel Engine driven generating set of capacity60 KVA, 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears alongwith automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB IV+ norms and foundation as per manufacturer\"s instructions etc.with following specifications: - |
| 67 | Technical Specifications : ENGINEEngine Rating -60KVAB.H.P- 72Stroke- 4No. of Cylinders & Configuration- 4 & Inline RPM 1500Direction of Rotation- Counter Clockwise viewed from flywheel end Method of aspiration- Turbocharged Inter CooledMethod of cooling - Coolant cooledType of governor-ElectronicBattery Volts- 12VFuel Tank Capacity- 140 Ltr. or as recommended by OEMBore / Stroke -104 x 113 or as per specification by OEMDisplacement- 3.84 Ltr. or as per specification by OEMLube Oil Change Period -750 hours or as recommended by OEMExhaust After treatment System- EGR + DOCApplicable Standards- BS 5514 /ISO 8528Overload capacity- 10% for 1hr. For every 12hrs. RunningLube Oil Grade / Specifications- as recommended by OEMGenerator Controller -GC 1206 |
| 68 | ALTERNATOR:-Rating : 60KVAKW : 48KWType : BrushlessExcitation : Self excited, self regulated (AVR)Enclosure : SPDPEnclosure protection : IP-23Rating : ContinuousRated current : 83.4AmpsRated Voltage : 415VFrequency : 50HzPower factor : 0.8pf.Class of Insulation : HVoltage Regulation : ±1%Overload capacity : 10% for 1hr. for every 12hrs. running.Applicable standards : IS 4722/BS 5000ACCESSORIES:The following accessories will be supplied along with the D.G.Set1. Suitable capacity Fuel Tank far running continuously 8 hrs. The fuel tank will bemounted inside the canopy with connections.2. Anti-vibration mounting pad (mounted inside the canopy)3. Residential silencer ( fitted on top of canopy)4. Exide make 12V Battery with lead.5. First filled of Lub oil & Coolant. |
| 69 | MICROPROCESSOR BASED AMF CONTROL PANEL:-The AMF Control panel shall be made of 16SWG CRCA Sheet, indoor type, dust and vermin proof, Pre-Treated and Powder coated - suitable for 415 V, 3Phase, 50Hz system to be fitted inside Acoustic Enclosure.• Panel shall consist of the following Equipment’s:• Microprocessor based AMF Controller with display features for Engine &Alternator parameters.• Current Transformers of suitable ratio.• MCB/HRC Fuse for Control protection.• Cluster Type Indicating Lamps for DG ON/Load ON/Mains ON.• MCCB of Suitable Rating -1 Set with 2 Sets of Power Contactor – For Mains & DGIncomer.• FRLS Type Copper Flexible cable for Switchgear Interconnections.• Suitably rated Auxiliary Contactors/Relays.• Earth Studs.• Battery Charger• Electronic Voltage Regulator(EVR) |
| 70 | ACOUSTIC ENCLOSURE:-Acoustic enclosure shall be made of specially procured CRCA Sheet and structural sheet metal Base frame and comply with CPCB-IV+ norms with following features :(a) The most compact, six sided close, modular construction and detachable.(b) Meet CPCB-IV+ / MOEF norms.(c) Sound level < 75 dBA at one meter distance.(d) Easy accessibility around the DG Set, which ensures optimum serviceability.(e) Special power coated enclosure, weather proof, corrosion resistant, environment friendly.(f) Specially designed lifting hooks.(g) Use of high quality hardware ensures longer life of enclosure.(h) Provision for emergency stop facility.(i) Fuel tank is specially designed and mounted inside of the enclosure as a integral part of Acoustic enclosure.Note : (i) Necessary civil work for foundation as per OEM is deemed to be incl in the quoted rate.(ii) Necessary testing cost as directed by Engr-in-Charge and tpt is deemed to be incl in the quoted rate. |
| 71 | Supply, installation, testing and commissioning of 63 KVA, 415/415V (Fixed Ratio), 3 Phase, 50 HZ, ONAN cooled oil immersed copper wound outdoor type ISOLATION TRANSFORMER complete with first filling of IS: 335 ISI marked filtered & dehydrated transformer oil electrostatic sheild between primary 415V in delta connected & secondary 415V in star connected complete & other standard fitting/ accessories with VECTOR GROUP Dyn-11 with cable box on primary and secondary side with MCCB at output side, as per latest IS codes and complete with foundation etc and as specified and directed.Note : Cost of transformer oil, transportation, insurance, foundation etc or anything technical required for successful installationmand commissioning have deemd to be incl in the unit quoted rate. |
| 72 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 4.0 corefixed to wall as per IS 7098 (Part I) etc including cable glands, aluminium lugs complete all as specified and as directed.Note : Earth work, Brick cable cover protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. |
| 73 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 4.0 corefixed to wall as per IS 7098 (Part I) etc including cable glands, aluminium lugs complete all as specified and as directed.Note : Earth work, Brick cable cover protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. |
| 74 | S & F wall mounted Busbar chamber made of ETP grade copper of capacity 100 A , 4 Way with suitable size of enclosure and connected accessories, Complete all as specified and as directed. |
| 75 | Supply and fixing end termination joint kit for LT cable, heat shrinkable, outdoor type with jointing material & accessories suitable for voltage 1.1 kV (Earthed), 3.5/4 core25-50 sqmm complete all as directed by Engr-in-charge. |
| 76 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 77 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to desired thickness complete all as specified and as directed.(Note: Punned thickness shall be measured for payment purpose) |
| 78 | Supply and fixing steel tubular swaged pole, type 410 SP 31 (Overall length 09.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)Design / drawing of HT pole showing the layout and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved fromAGE(I) before placing order to the manufacturer. |
| 79 | M & L for Stay assemblyhaving stay rod dia 20 mm complete with all accessories such as mild steel galvanized flat iron stay clamp, all as shown in electrical plate No 1 of SSR Part-I 2009 complete all as specified andas directed.[Note : Excavation, earthwork and cement concrete work shall be measured and paid separately under relevant Items of this schedule]. |
| 80 | M & L Loop Insulator for stay assembly Overall dimensions 90 x 140 mm & clearance of hole 25.5 mm, complete all as specified and as directed. |
| 81 | M & L for 7/4 mild steel galvanized stay Strand,complete all as specified and as directed. |
| 82 | M & L for 80 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures /poles complete all as specified and directed. |
| 83 | M & L for Aluminium conductor steel reinforced (ACSR) (weasel type) for making connection at poles etccomplete all as specified and directed. |
| 84 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified & as directed. |
| 85 | M & L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified & as directed. |
| 86 | Supply & Fixing of MCCB FP of capacity 125 A, 25 KA 4pole with metal encloser and connected accessories, complete all as specified and as directed. |
| 87 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Feeder pillar, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 150 Amps rating TPN bus bars of high conductivity Copper Alloy of size25x5mm and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 55.(Cont...) |
| 88 | The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:[a] MCCB, 125 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, B Curve – 1 Nos [Incoming][b]Spreaderlink – 1 No.[c] Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 1 Nos [1 Set].[d] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.[e] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. |
| 89 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of bus bars of high conductivity Aluminium Alloy of suitable size and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 55.(Cont...) |
| 90 | The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:[a] MCCB 125 Amp 4 pole 415 VoltsAC with thermal magnetc adjustable type 16 KA lcs = 100% lcu-02 Nos( I/C from DG set AMF Panel & O/G to Isolation TFR & 01 for Bypass)[b]MCCB 100 Amp 4 pole 415 VoltsAC with thermal magnetc adjustable type 16 KA lcs = 100% lcu-03 Nos (O/G fromLT Panel) (01 as stand by)[c]MCCB 63 Amp 4 pole 415 VoltsAC with thermal magnetc adjustable type 16 KA lcs = 100% lcu-01 No. [d] Changeover Switch on load type 125 amps, 4 pole -01 No.[e] Aluminium bus bar of suitable capacity of suitable length duly insulated with colour code- 04 Nos [f]MCB SPN 32 / 40 Amps, \"C\" Series, 10 KA, 240 Volts -02 Nos[g]Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 2 Nos [1 Set].[h] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 2 Nos.[j] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. |
| 91 | aterials and labour for earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of 20 x 3mm sizeby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) completeall as specified and as directed.Note: (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 92 | Materials and labour for earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of 25 x 3mm sizeby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and as directed.Note: (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 93 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. o the department. |
| 94 | Materials and labour for earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI strip of 25 x 4mm sizeby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completionall as specified and as directed. Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 95 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail