| 1 | S&F in repair/replacement fan motor single phase 230 Volts, 1400 RPM 3 speed 1/8 HP copper wound for desert cooler complete all all as specified & directed by the Engineer-in-charge. Make Crompton/bajaj/usha |
| 2 | S &F in repair/replacement, desert cooler selector switches three way 230 volts single phase complete all as specified & directed by Engineer-in-charge. |
| 3 | S&F in repair/replacement, plug top 3 pin 5 amps, 230 volts (ISI marked) complete all as specified & directed by Engineer-in-charge. Make C&S/ Anchor/Legrand or equivalent |
| 4 | S&F in repair/replacement, capacitor 2.5 suitable for 4000/5000/6000 cfm for fan motor of desert coolers complete all as specified & directed by Engineer-in-charge. Make-Epcos/Bajaj/ Havells/CG |
| 5 | S&F in repair/replacement, submersible pump PVC body 230 volts, 1/60 HP for desert cooler complete all as specified & directed by Engineer-in-charge. Make- Khaitan/AjantaUniversal. |
| 6 | S & F of wood wool pads of size 450mmX600mm set of three of best quality with and including wire netting (chicken wire mesh) as approved by Engr-in-Charge complete all as specified and directed . |
| 7 | S&F in repair fan motor suitable for water cooler of capacity 40/80 ltrto 150/180 ltr, copper wound complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 8 | S&F in repaircondensor coilof water cooler of capacity 40/80 to 60/120 ltr complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 9 | S&F in repairs fan blade suitable for water cooler 60/120 liters complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 10 | S&F in repair, capacitor 10/15 MFD (suitable or as per existing sample) for fan motor of water coolers/refrigerator complete all as specified & directed by Engineer-in-charge. Make-Bajaj/ Havells/CG or equivalent. |
| 11 | S&F in repairs float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 140 grams/each, suitable for water/desert coolers complete all as specified & directed by Engineer-in-charge. Make- Prayag or equivalent |
| 12 | S&F in repair, relay and over load protector set suitable for water cooler/refrigerator of any capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 13 | Repair of top door of the any capacity water cooler with the help of welding, hinges, nuts bolts washers and scratching the old rust hole area of the body part, applythe automotive body putty smoothening with sand paper, clean the entire part, apply the primer and paint complete all as specified by the Engineer-in-charge. |
| 14 | S&F in repair, PVC drain out pipe, heavy duty 32/40 mm dia, wall thickness 2 mm having length not less than 1.0 mtr complete with fittings such as nipple, clip etc complete fixed to water coolers of any capacity complete all as specified & directed by Engineer-in-charge. |
| 15 | M&L for cutting and removing unservicable freezer unit of refrigerator capacity 310/320 Litres of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 16 | S&F in repairs thermostat suitable for refrigerator 165 to 320 litres capacity complete all as specified & directed by Engineer-in-charge. Make-Theeta/Racold/Tasspass |
| 17 | M&L for servicing of spilt type AC of capacity 1.5/2TR of any make by opening the condenser unit fixed on outside and cooling unit fixed inside the building,and cleaning (Including complete pressurized chemical washing with pressure pump and plastic bag covering avoid dust & water spreading) the complete condensor unit and cooling unit including fins and checking/testing of all parts for its serviceability, andrectification of unusual noise of motors, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified & directed by Engineer-in-charge. |
| 18 | M&L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning (Including complete pressurized chemical washing with pressure pump and plastic bag covering avoid dust & water spreading)the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oilling/greasing to condenser cum blower fan motors, rectification of unusual noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified & directed by Engineer-in-charge. |
| 19 | S&F in repair/replacement outdoor fan motorof split type A/C 1.5/2 TR capacity, complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 20 | S&F in repair blower fan motor of capacity 1/30 or 1/20 HP copper wound suitable for split type AC1.5 /2 TR, AC/DCcomplete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 21 | M&L for removing the condenser fan motor from window type A/C of 1.5/2TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with \"E\"class varnish, including replacement of gun metal bush, side rubber packing and refixing of motor in original position with new washer nuts & bolts complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 22 | S&F capacitor 35 to 70 MFD (3/ 4 pin/6 pin or existing) suitable for A/C of capacity 1.5/2 TRcomplete all as specified & directed by Engineer-in-charge. Make-Epcos/Havells/CG or equivalent |
| 23 | Repair of refrigerator fan motor suiable of cap 165 ltr/285/310 ltr complete including testing complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model. |
| 24 | S&F in repair, fan blowerof window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 25 | Taking out compressor of window type AC of 1.5 /2TR and supply and fixing the compressor with jointing of copper refrigerant pipe line in and including charging of refrigerant gas to required level complete all as specified & directed by Engineer-in-charge. Make- Hitachi,LG,Voltas or equivalent. |
| 26 | S&F in repair, ofthermostat suitable for split/window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Theeta/Racold/Tasspass |
| 27 | S&F in repair, copper condenser suitable for split type AC of capacity 1.5/2 TR complete including top up gas charging and checking all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 28 | S&F in repair/replacement, plug top three pin 15/16 Amps 230 volts AC complete all as specified & directed by Engineer-in-charge. |
| 29 | S&F in repair, Air Filter for Air conditioner split type having capacity1.5/2.0 ton (Set of 2 pieces) complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 30 | S&F in repair, PCB suitable to Split type AC 1.5/2 TR(ordinery/Invertor) complete all as specified & directed by Engineer-in-charge. Make- As per existing make |
| 31 | S&F in repair, PCB suitable to refrigerator to any capacitycomplete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 32 | S&F selector Switch for window type AC having capacity1.5 ton complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 33 | S&F in repair copper tube size 1/4\" of split AC having capacity 1.5/2 ton complete all as specified & directed by Engineer-in-charge. |
| 34 | M&L in repair for swing motor of split AC any make any type all as per sampleall as specified & directed by Engineer-in-charge |
| 35 | M&L in repair for split AC valve of ½” dia all as per sampleall as specified & directed by Engineer-in-charge |
| 36 | S & F replacement exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 rpm, copper winding of sweep 250mm. Note : Old unserviceable damage exhaust fan deposited by MES Store yard. |
| 37 | M&L in repair for split AC valve of ¼” dia all as per sampleall as specified & directed by Engineer-in-charge |
| 38 | Taking out of old compressor S&F for compressor of deep freezer of capacity150/180/210 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge.Make- As per existing make and model |
| 39 | Taking out of old compressor S&F for compressor of water cooler of capacity 60/120 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 40 | S&F in repair, copper condensing coil suitable for refrigerator of capacity 165 to 320liters complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 41 | S&F in repair heaterrefrigerator capacity 160 to 320 Litres complete all as specified & directed byEngineer-in-charge. Make- As per existing make and model |
| 42 | S&F in repair, capillary tube suitable for any make & capacity water cooler/refrigerator complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model. |
| 43 | Supply & charging ofrefrigerant gas R-32 (freon) for charging in window/split type AC of 1.5/2 TR capacity complete and checking of leakage, testing for proper functioningall as specified & directed by Engineer-in-charge. |
| 44 | Supply & charging ofrefrigerant gas R-410A for charging in Refrigerator/water cooler/DF/ window/split type AC of 1.5/2 TR capacity complete and checking/testing for proper functioningall as specified & directed by Engineer-in-charge. |
| 45 | Supply & charging ofrefrigerant gas R-134C/R-32 (freon) for Refrigerator/water cooler/DF/ window/split type ACs of any capacity complete and checking/testing for proper functioningall as specified & directed by Engineer-in-charge. |
| 46 | Supply & charging ofrefrigerant gas 600A for refrigarator/water cooler of any capacity complete and checking/testing for proper functioningall as specified & directed by Engineer-in-charge. |
| 47 | S&F in repairtransformer ofvoltage stabilizer 4/5 KVA and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with \"E\" class varnish, including and reassembling and fixing in position complete all all as specified & directed by the Engineer-in-charge. |
| 48 | S&F in repair, PCB circuit of existing size and shape of volatage stabilizer 4/5 KVA complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 49 | S&F in repair relay of volatage stabilizer 4/5 KVA complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 50 | Taking out of old compressor S&F for DC compressor ofrefrigerator of capacity 160 to 340 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessories like relay with over load protector, filter & supply &recharging of refrigerant complete including testing for smooth functioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 51 | Taking out of old compressor S&F for DC compressor of inverter split type AC of 1.5TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model |
| 52 | M & L sub main wiring of two single core PVC insulated unsheathed stranded copper conductor cables of size 2.5 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 1.5sqmm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed. (Phase-Red, Neutral – black in colour of cable) |
| 53 | Supply & fixing in replacement of defective capacitor of size 2.5 mfd ISI marked for any type of each fans suitable for 250V/230V including making connection complete all as specified and as directed. |
| 54 | S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC Fan) complecte all as specified Note : Old unserviceable ceiling Fan deposited by MES Store yard.. |
| 55 | M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site andreplace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and front grillmade out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction,03 Nos perforated sheet side panels size Approximet 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch with new motor & pump fitting complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally complete all as specified and directed.Note : Old unserviceable damage desert cooler deposited by MES Store yard. |
| 56 | Taking out existing defective/unserviceable and renewal with new S&F out door unit split type 1.5 TR with rotary compressor and copper tube condensors with metal fan blade and motor with all connected items reqd for its installation including new copper tube insulated and make complete all as specified and directed by Engr-in-charge. |
| 57 | Taking out existing defective/unserviceable and renewal with new S&F indoor unit split type 1.5 TR complete with all connected items i.e copper tube cooling coil,PCB ,blower motor,filter and make complete all as specified and directed by Engr-in-charge. |
| 58 | Supply only in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |