| 1 | Replacement of V belts any size as required andas directed for DG Sets of capacity 15KVA to 125KVA Complete all as specified & directed. |
| 2 | Repair and cleaning of radiators of DG set of capacity 62.5 to 125 KVAand removing the radiators from engine for repair and washing with caustic soda and cleaning with blower including brazing of damaged water tubes/fins and make itfully functional for DG Setincluding other minor repairs complete all as specified and directed. |
| 3 | Comprehensive maintenance of DG Set of Capacity62.5 to 125 KVA including checking for loose electrical making them fixed, Calibrating all relays Check safety alarm, Change of Lub oil & Coolant top up and make DG set fully functional includung other minor repairs complete all as specified and directed.Note: change of spares /Lub oil/Coolant will be paidunder relevant items of this schedule. |
| 4 | Supply only Lub Oil Filter of existing make as required for DG set cap. 62.5 KVA |
| 5 | Supply only Air Filter as per existing make for DG Set of Cap. 62.5 KVA |
| 6 | Supply only Diesel filter as per existing make for DG set of cap. 62.5 KVA |
| 7 | Supply onlyLub Oil Filter as per existing make for DG set cap. 75 KVA |
| 8 | Supplyonly AirFilter as per existing make for DG set of Cap. 75 KVA |
| 9 | Supply only Diesel filter as per existing make for DG set of cap. 75 KVA |
| 10 | Supply onlyLub Oil Filter as per existing make for DG set cap. 125 KVA |
| 11 | Supplyonly AirFilter as per existing make for DG set of Cap. 125 KVA |
| 12 | Supply only Diesel filter as per existing make for DG set of cap. 125 KVA |
| 13 | Supply onlyLub Oil Filter as per existing make for DG set cap. 15 KVA |
| 14 | Supplyonly AirFilter as per existing make for DG set of Cap. 15 KVA |
| 15 | Supply only Diesel filter as per existing make for DG set of cap. 15 KVA |
| 16 | S & F in repair Sealing Ring as per existing make for DG set of Cap. 125KVA |
| 17 | S & F in repair control display Panelof DG set 125KVA as per existing make Complete all as specified & directed. |
| 18 | Supply only Lub Oil Suitable for DG set 15 KVA to 125 KVA Complete all as specified & directed. |
| 19 | Supply only Coolant Suitable for DG set 15 KVA to 125 KVA Complete all as specified & directed. |
| 20 | Supply, install, testing and commissioning of cubical type CPRI approved LT feeder pillar box, Double Door , Outdoor type mounted on pedestal factory made, totally enclosed with necessory ventilation weather, dust and vermin proof (also to confirm IP-54 standard), front and rear opening and locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15 mm thick as per IS 8623 duly painted with powder coated paint of approved shade after minimum seven tank treatment process.The panel shall be suitable for 415 volts , 50 HZ, 3 phase 4 wire system and shall be complete with 400 Amps capacity copper bus barwith suitable size copper conductor duly insulated with PVC coloured heat shinkable type sleeves,thimbles glands and Digital Ammeter 0-250Amps, 3 phase class 1.0 with integrated selector switch and CTs duly prewired and Digital voltmeter 0-433 Amps and also fitted with indicator lampsshall be complete all as directed with the following accessories including taking out of old unserviceable LT Feeder pillar box. INCOMMING(a) MCCB, 4 pole, 400 Amp, 50 Hz, 415 Volt , thermal based release with rupturing capacity, 36 KA-01 NosOUTGOING(a) MCCB, 4 pole, 250 Amp, 50 Hz, 415 Volt , thermal base release with rupturing capacity, 25 KA-01 No (b) MCCB, 4 pole, 125 Amp, 50 Hz, 415 Volt , thermal base release with rupturing capacity, 25 KA-02 NoC) MCB 4 Pole 100 Amp , 50HZ ,415Volts thermal base release with rupturing capacity25KA Qty -01 No |
| 21 | S&F in repair contactor250A, 4 Pole 220 V, with 2 No, 2 NC all model CTX 150 4 polecomplete all as specified and directed. |
| 22 | S&F in repair HRC Fuse, Square shape, Capacity 400 Amp, Size 2, 80KA Complete all as specified & directed. |
| 23 | Repair and maintenance ofLT panels of different sizes incl copper strip including taking off old U/S Strips fixing with new strips with nuts and necssray connectionsMS sheet 16 SWG(1.6 mm) and fabrication of back side and front sidecover of LT panel including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of coats of synthetic enamel paint over a coat of red oxide primer etc, fixing panel gates with proper fixing screws complete all as specified and as directed. |
| 24 | S&F in repair selector switch for voltmeter complete all as specified and directed. |
| 25 | S&F in repair selector switch for ammeter complete all as specified and directed. |
| 26 | S&F in repair RYB 3 phase LED indicator lamps (set of 3) complete all as specified and directed. |
| 27 | S&F in repair voltmeter 0-500 V, Digital type 3 phase any size as required on site complete all as specified and directed. |
| 28 | S&F in repair Ammeter 0-500 A, Digital type 3 phase any size as required on site complete all as specified and directed. |
| 29 | Supply, install, test and commission cubicle type CPRI approved LT feeder pillar box, Double Door , Outdoor type mounted on pedestal factory made, totally enclosed with necessory ventilation weather, dust and vermin proof (also to confirm IP-54 standard), front and rear opening and locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15 mm thick as per IS 8623 duly painted with powder coated paint of approved shade after minimum seven tank treatment process.The panel shall be suitable for 415 volts , 50 HZ, 3 phase 4 wire system and shall be complete with 400 Amps capacity copper bus barwith suitable size copper conductor duly insulated with PVC coloured heat shinkable type sleeves,thimbles glands and Digital Ammeter 0-250Amps ,3 phase class 1.0 with integrated selector switch and Cts duly prewired and Digital voltmeter 0-433 Voltmeter and also fitted with indicator lampsshall be complete all as directed with the following accessories:INCOMMING(a) MCCB, 4 pole, 160 Amp, 50 Hz, 415 Volt , thermal based release with rupturing capacity, 36 KA-01 NosOUTGOING(a) MCCB, 4 pole, 100 Amp, 50 Hz, 415 Volt , thermal base release with rupturing capacity, 25 KA-02 No(b) MCCB, 4 pole, 125 Amp, 50 Hz, 415 Volt , thermal base release with rupturing capacity, 25 KA-02 Noc) MCB 4 Pole 100 Amp , 50HZ ,415Volts thermal base release with rupturing capacity25KA Qty -01 no. |
| 30 | Supply And Laying in repair 50 Sqmm 4 core XLPE insulated, steel armoured, 1100 Volts grade in trenches / ducts / through pipes / on poles / roads fixing to the poles through clamps and connecting up, testing and commissioningincluding taking down old unserviceable LT UG cables, jointing and testing complete all as specified and as directed.Note: Excavation and earth work will be measured and paid separately under relevent items of this schedule. |
| 31 | Description all as per BoQ Srl item no. 30.00 here-in-before but of size 70 Sqmm 3.5 core |
| 32 | Description all as per BoQ Srl item no. 30.00 here-in-before but of size 95 Sqmm 3.5 core |
| 33 | Description all as per BoQ Srl item no. 30.00 here-in-before but of size 150 Sqmm 3.5 core |
| 34 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying of cable and foundation of pole etc complete all as specified and directed. |
| 35 | Returning, filling in,including spreading, leveling, watering & well ramming in layers not exc. 25 cm for soil complete all as specified and directed. |
| 36 | Removal of excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed. |
| 37 | Supply and lay in repair double wall corrugates (DWC) high density polythethylene pipes having corrugation on the outer wall and plain surface on the inner wall and plain surface on the inner wall for protection of underground cables. Inner dia of pipe 75mmwith all fittings .LAid in trenches /road/nallah or fixed along wall,poles or laid under floor for cable protection all as specified and directed Note: 1 Cost of inserting cable in pipe deemed to be included in quoted rate . |