| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for cement plastering 15mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer\"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately. |
| 3 | Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge. |
| 4 | M&L for cement plastering 10 mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for cement plastering 10mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. |
| 7 | Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. |
| 8 | M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed |
| 9 | Material & labour Applying 02 coats of exterior emulsion weather proof paint (light shade) to external newplastered walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommendedby manufacturer of exterior emulsion and primer complete all as specified and directed. |
| 10 | Material & labour Applying one coat of exterior emulsion weather proof paint (light shade) to external old plastered walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including preparation and cleaningsurfaces complete all as specified and directed. |
| 11 | Material & labour for Preparation of plastered/old plastered surfaces of wallsand applyingtwo coats of cement base paint complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & labour Applying 02 coats of interior oil bound distemper (light shade) to new plastered wall surfaces over & including a coat of interior wall primer complete all as specified and directed. |
| 13 | Material & labour Applying one coats of interior oil bound distemper (light shade) to old plastered wall surfaces including preparation and cleaningsurfaces complete all as specified and directed. |
| 14 | Material & labour for preparation of newplastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & labour for preparation ofold plastered surfaces of ceiling and applying one coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material & labour for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcherwith cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. |
| 17 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified. |
| 18 | Material & labour for Brick work with sub class \"B\" bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 all as specified. |
| 19 | Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises. |
| 20 | Material & labour for Non - skid coloured Ceramic tiles 8mm thick (square/ rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cementslurry over and incl 15 mm thick cement mortar (1:4) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material & labour for Glazed ceramic coloured printed/digitaltiles area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,onvertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material & labour for Virified Ceramic tiles(light shade) 10 mm thick (square/ rectangular) polished, size of each 600mm X 600mm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match, joined in cement slurry over and incl 15mm thick cement mortar (1:4) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-charge. |
| 23 | Demolition of cement concreteun -reinforced in ground floors and pavings complete all as specified and directed. |
| 24 | Material & labour for Baroda green Marble work 18 to 20mm thick (table rubbed and polished)in steps, windowcills,laid over 15 mm in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shadeincluding rubbing and polishing to mirror finish complete to be fixed in any position as described and specified. |
| 25 | Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge. |
| 26 | Material & labour Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granitecomplete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & fixed vitreous china premium/1st quality wash basin white/ivory/off white, flat back, size 550x400 mm including pedestal, screws & plug and brackets etc. all accessories as recommended by manufacturer incl. CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union andincl 32mm brass CP waste coupling and completein all respect as per manufacturer\"s instructions and taking down existing of any description/size all as specified. |
| 28 | Supply & fixed vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) S/P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors except G.F.and taking down existing of any description/size complete in all respect all as specified. |
| 29 | Supply & fixing vitreous china premium/1st quality Orissa Pan water closet white colour of size 580X440mm including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe and including and taking down existing of any description/size complete in all respect all as specified. |
| 30 | Supply & fixed in repair 100 mm Cast iron Traps ‘P’ or ‘S’ , 600mm long,complete all as specified and directed. |
| 31 | Supply & fixed in repair flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified. |
| 32 | Supply & fixed in repair Bib taps,CP,fency type long body with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete in all respect all as specified. |
| 33 | Supply & fixed in repair 15 mm dia Stop cock cast copper alloy fancy type CP with long shank and cup (concealed type), screw down high pressure, screwed both ends for iron pipe or for union and fixedcomplete all as specified and directed. |
| 34 | Supply & fixed in repair Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified. |
| 35 | Supply and fixing PVC connections 15mm size with PTMT nuts of length 450mm. complete in all respect all as specified. |
| 36 | Supply & fixing Pillar taps, fency type, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed in repairs all as specified. |
| 37 | Supply & Fixing acrylic glass shelf assembly for soapdish and appropriate space for placing other things like tooth brushes comb tooth paste etc and fiexed to walls with plug and brass chromium plated screws complete all as specified and directed. |
| 38 | Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store. |
| 39 | Taking up or down 20 mm steel tubing and connections, including cleaning for refixingor removal to store. |
| 40 | Supply and fixing 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified. |
| 41 | Supply and fixing 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified. |
| 42 | Supply and fixing 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 43 | Supply and fixing doubled layered rotational moulded polyethylene white colour water storage tanks (with closed top/cover) 500 ltrs capacity hoisted and fixed in position all as specified including ball brass valves,high pressure,with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank including taking down complete all as specified and directed. |
| 44 | M & L for mild steel framed work as in brackets etc for cooler stands,supportings frame workfor sun shadeetc framed steps/stairs etc complete using MS railing/angle iron Steel bars gusset plate etc complete all as specified & directed complete. |
| 45 | Material & labour for Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in plinth protection/ floor finish, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints filled with Bituminous mastic asphalt complete all as specified and directed by Engineer-in-Charge. |
| 46 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge |
| 47 | Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) |
| 48 | Material & labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material & labour for Cutting grooves in brick wall, 50mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material & labour for PCC 1:3:6, type B-0 using 12.5mm graded stone agg as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & labour for Providing and laying3mm thick APP (Atactic Polyproplene Polymer) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified, Thelaying of membrane shall be gotdone through the authorised applicator of manufacturer of membrane only complete all as specified and directed by Engineer-in-Charge. |
| 52 | M&L for Aluminium painting 2 coatsover a coat of primer on APP surface by using roller/brush as per manufacturer, complete all as specified and directed. |
| 53 | Material & labour for 20- 22 mm Precast PCC plain factory made tiles,ISI marked,22 mm thick, of size 250 mm x 250 mm, machine pressed and cut polished and set jointed and pointed in neat cement slurry andfabricated using grey cement & no pigments. over and including 15 mm thick cement mortar (1:4) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge. |
| 54 | Material & labour for PCC 1:2:4, type B-0 using 12.5mm graded stone agg as in roof curve, benching, mud stops, steps, coping and the like items slightly rounded or chamfered on the edges complete all as specified and directed by Engineer-in-Charge. |
| 55 | M& L forFlush pointing in cement mortar 1:3, to bricks laid flat or brick tiles in pavings, aprons etc,complete all as specified and directed. |
| 56 | Demolition of cement concrete (unreinforced) of of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and directed. |
| 57 | Material & labour 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate in sub base,complete all as specified and directed by Engineer-in-Charge. |
| 58 | Material & labour for Machine pressed precast concrete interlocking paver block with Grey Cement and no pigment of any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over base complete all as specified and directed by Engineer-in-Charge. |
| 59 | Material & labour sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-charge. |
| 60 | Material & labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set with grey cement and pigment , jointed and pointed in neat cement slurry in floors incl 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 61 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. |
| 62 | Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 105x60mm including filling of PCC 1:3:6, using 12.50 mm graded aggregatein chowkhatsand PCC 1:2:4 B1 as in hold fasts blocks including necessary form work complete as specified. |
| 63 | Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 125x60mm including filling of PCC 1:3:6, using 12.50 mm graded aggregatein chowkhatsand PCC 1:2:4 B1 as in hold fasts blocks including necessary form work complete as specified. |
| 64 | Supply & fixing factory made flush shutters 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 65 | Supply & fixing 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass,gauze etc (without sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Pt-I section 8 clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed. |
| 66 | Material & labour Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 complete all as specified and directed. |
| 67 | Material & labour PCC (1:2:4 ) type B1 using 12.50 mm graded aggregate as infilling in PS Chowkhats/Holdfast Block all as specified . |
| 68 | Supply & fixing Butt hinges 100 mm size,medium weight stainless steel complete all as specified and directed. |
| 69 | Supply & fixing Aluminium alloy, anodised, sliding door bolt 250 mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 70 | Supply & fixingAluminium anodised, barrel tower bolts of 200 mm size of extruded section and fixed complete all as specified and directed. |
| 71 | Supply & fixing powder coated aluminium handles 125mm complete all as specified and directed. |
| 72 | Supply & fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in repair with stainless steel wire stapples, in steel/wooden frame complete all as specified and directed. |
| 73 | Supply & fixing of 3 mm thick plain glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane, fixed in repair complete all as specified and directed. |
| 74 | Taking down chokhats or frames (without taking off shutters from the frame) n.exc 1.50 sqm including cutting holes and making good reqd shape for hold fast block for new frame complete all as specified directed. |
| 75 | S& F Factory MadeSolid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge. |
| 76 | S& F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification complete all as specified and directed by Engr-in-Charge. |
| 77 | Steel window box type usning ERW hollow \"P\" section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, etc including 8nmm sqauare gaurd bars complete all as specified and directed by Engr-in-Charge. |
| 78 | Supply & fixingfor 3 mm figured glass sheet ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified. |
| 79 | Supply & fixing for PVC(HDPE) rain water pipes, 110 mm bore,double socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc includingtaking down existing damaged CI rain water pipe complete all as specified and as directed |
| 80 | Supply & fixing PVC (SWR) white coloured bends of any radius for 110mm bore as in repair complete all as specified. |
| 81 | Supply & fixing PVC (SWR) white coloured single tees of any radius for 110mm bore as in repair complete all as specified. |
| 82 | Material & Labour for welding of steel, aluminium or iron work of thickness Exc 6 mm and n exc. 20 mm in repairs complete fixed in all respect as specified |
| 83 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engr-in-Charge. |
| 84 | M&L PCC 1:4:8using 40 mm graded stone aggregate as in foundation filling and mass concrete for fixing RCC/ any fencing posts complete all as specified and as directed |
| 85 | Supply & fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240,concrete complete all as specified . |
| 86 | S&F for pre-painted galvatume aluminium zinc coated GI based corrugated, steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roofing covering/cladding to wall, fixed with self tapping screws as specified. |
| 87 | Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent, having 100%elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications.Product Make: Fosroc/Dr Fixit/Sikka |
| 88 | Supply and apply of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturer\"s instructions and all as specified.Note : Theapplication of rust removal shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed.Product Make: Fosroc/Dr Fixit/Sikka |
| 89 | Supply and apply Cementitious Coating for Corrosion Protection having a cement based polymer modified rebar corrosion protection system by appling the first coat approx. 1mm thick layer of product carbonation resistance 2 mm of SikaTop Armatec®-108 or equivalent as specified corresponds to 20 mm of normal mortar; bond strength > 1N/mm2 according to ASTM C 882-78 applying @ 4 kg/m2 for two coats onto the prepared reinforcing steel with a medium- stiff brush. It is unavoidable that Sspecified product will also be applied onto the surrounding concrete. The second coat is applied in the same way after a waiting time of 2-3 hours (at +20°C) complete all as per manufacturer\"s instructions and all as specified.Note : Theapplication of Cementitious Coating for Corrosion Protection shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed.Product Make: Fosroc/Dr Fixit/Sikka |
| 90 | Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer\"s specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereeverrequired and as per directions of Engineer-in-charge.Consumption: 0.5 kg/m2. complete all as per manufacturer\"s instructions and all as specified.Product requirements: Complies with ASTM C 881 Type II Grade 2 Class B+C.Note : Theapplication of Epoxy Bonding Primer shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed.Product Make: Fosroc/Dr Fixit/Sikka |
| 91 | Supply and apply a pre-batched one component polymer modified cementitious patch repair mortar in25 mm thickness.Yield: approx. 0.84 ltr/kg.System requirements: compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; flexural strength >= 3N/ mm2 (7 days) according to ASTM C 293-79.Consumption of 2.1 Kg/Sqm/mmNote : Theapplication of Polymer repair Mortar shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed.Product Make: Fosroc/Dr Fixit/Sikka |
| 92 | Taking down carefully existing points wiring on surface conduit/concealed conduit forlight/ fan/socket /power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion ofwalls, ceiling etc all as specified and directed Engr-in-charge. |
| 93 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plateincluding 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directedby Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item).Note -IV - cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item. |
| 94 | All as per Sl item No 93.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 95 | All as per Sl item No 93.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 96 | All as per item No.93.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copperearth wire for switch socket combination 3 pin 15 amps on independent board. |
| 97 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plateincluding 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dollycontrolled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directedby Engineer iin-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost ofmodular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. |
| 98 | All as per Sl item No 97.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 99 | All as per Sl item No 97.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 100 | All as per item No 97.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-strandedcopper earth wire for switch socket combination 3 pin 15 amps on independent board. |
| 101 | Supply and fix in replacement of Modularswitch1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge. |
| 102 | Supply and fix in replacement of Modularswitch1 way, 16 Amps, 1 module complete all as specified and directed by Engr-in-charge. |
| 103 | Supply and fix in replacement of Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by Engr-in-charge. |
| 104 | Supply and fix in replacement of Modularsocket 5 pin 6/16 Amps, combination type2 module complete all as specified and directed by Engr-in-charge. |
| 105 | Supply and fix in replacement of Fan regulator modular type 2 module complete all as specified and directed by Engr-in-charge. |
| 106 | Ceiling rose surface bakelite surface 65 x 50mm3 terminals all as specified & directed by Engr-in-charge. |
| 107 | Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07,with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. |
| 108 | Supply and fixing LED flat panel 2 x 2 ft size fully diffused surface mounted fitting (grid/gypsum type) 36-40 watt, 5700K/3000 K warm/cool white with powder coating and CRCA front cover incuding frame with provision of PVC flexible copper conductor cable from ceiling rose to light fittings as in repair complete all as specified and directed by Engr-in-charge. |
| 109 | Supply and fix in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge. |
| 110 | M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit)Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 111 | M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runsof 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Runof 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit)Note2 : Rate quoted for this items shall be inclusive of the cost of(i) Rigid non-metallic PVC conduit of 25 mm dia withtees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc.10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.(iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 112 | Supply and fix in replacement ofMCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. |
| 113 | Supply and fix in replacement of MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. |
| 114 | Supply and fix in replacement epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of thimble. |
| 115 | Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. |
| 116 | Supply and fix in replacement of Sheet metal enclosure 4 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. |
| 117 | S & F in replacement of MCB , SPN,240 Volts ,32-40 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge) |
| 118 | S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) |
| 119 | S & F in replacement ofMCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge) |
| 120 | M & L for replacement of UNSV Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick burieddirectly in ground(earthpit not less than 2.25m deep below normal level) connectedtogalvanised earth leadwire 4.0mm dia by means of nuts, bolts, &washers of GI as shownin electrical plate No 3 of SSR PartI.Connected to earthing test pointtesting complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement@ 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth leadshall be providedwith GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation including charcoal and common salt in alternative layers 15 cm Thick mixed refilling of soil etc complete all as directed by Engineer-in-charge. |
| 121 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised Strip of 25 x 4 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 122 | Supply & fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 18/20W 6500K cool /warm whiteof capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. |
| 123 | Supply and fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 10/12W 6500Kof capacity ,watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper conductor cable all as specified and directed byEngr-in-charge. |
| 124 | M & L for Sub main wiring (with approved colour coding as per IS)with single core FRLSH PVC insulatedmultistranded copper conductor1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulatedmultistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 1.5 sq. mm main cable + 1 run of 1.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note:(i) Two different color wires shall be used for phase andneutral . (ii)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item. |
| 125 | Supply and fix in replacement ofLED post top fitting 40 W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,ACsupply complete with all accessories internally pre wired including provision of 3 corePVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge.Note: Cost of GI pipe of suitable dia of length 4 feet, grouting holes into piller and cement work has beenincluded in the rate quoted by contractor |
| 126 | Supply and fix in replacement ofLED post top fitting 20 W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,ACsupply complete with all accessories internally pre wired including provision of 3 corePVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge.Note: Cost of GI pipe of suitable dia of length 4 feet, grouting holes into piller and cement work has beenincluded in the rate quoted by contractor |
| 127 | Supply and fix in replacement ofhighly reliable energy efficient multi high power LED with lensflood light designed with optimized optical performance and good heat dissipation with uniform distribution of capacity 80 Watt, CCT 5700-6500K, CRI>70, rated voltage 220V-240V AC, 50 Hz, Power factor>0.9, IP-66 dimension 290x235x155 mm epoxy powder coated pressure die casted aluminium housing with bright anodised aluminium reflectro and enclosed with heat resistant and toughened glass having constant current driver suitable for 140-280V AC working range suitable for facade lighting with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements complete all as specified and directed by Engr-in-charge. |
| 128 | Supply and fixing in replacement single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge. |
| 129 | S & F Ceiling fan 1200mm sweep energy efficentsuspended from fan hook includingconnecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan complete all as specified & directed.Note:-cost of anchor bolt for hanging of ceiling fan and grouting is deemed to beincluded in the unit rate quoted by contractor. |
| 130 | Supply and fixincl taking down LED garden light fitting cool/warm white with LED bulb upto 20 watt E27/B22 base cap fitted on the piller with the help of GI pipe of suitable height and PCC up to suitable height nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class ,connection with 1.5 sqmm 3 core copper cableincluding making suitable PCCfoundation and all electrical connection complete all as directed. |
| 131 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connectionsone twin core cable flat or circular stranded conductor size of 6 Sqmm, twin core complete all as specified. |
| 132 | S & F LED lamp invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt, Lithium ion battery including removing of unserviceable lamp complete all as specified and directed by Engr-in-charge. |
| 133 | Supply and fix Exhaust fan AC single phase 230/240 v of size 450 mm sweep heavy duty 1400 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver & Hole making complete all as specified and directedby Engineer-in-Charge. |
| 134 | Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back integrated aluminium batten with diffuser and including 20 Watt LED hight efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connectorof the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.Make: Philipsor as equivalent inHalonix/Crompton Greaves /osram /wipro |
| 135 | S/Fix in replacement of old MCB DB TPN 4 Way with 200Amp standerd bus bar factory made IP 43 protection class metal double doorwith Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCB TPN upto 125A complete all as specified and directed.(MCB TPN will be measured and paid separately under respective items of sch A) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail