| 1 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coatsapplied @ 1.67 ltr/ 10 sqm) on existing cement paint surfaceincluding removing the old existing exterior peeled off paint by scrapping, sand papering water washing,cement patch work in cement motor 1;6 where ever requiredand preparing the surface smooth including necessary repairs to scratches with exterior cement primer touch upetc. complete as directed by Engineer in-charge.(Asian ÄPEX\"or its equivalent approved make) |
| 2 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :One or more coats on old work as directed by Engineer in-charge.(Asian or its equivalent make) |
| 3 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing Cement plastering in cement mortor 1:6 after removing of partition where ever required including disposal of unserviceable material and stacking of serviceable material with in IICT campus as directed by Engineer-in charge. |
| 4 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 5 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters/fixed portions of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 6 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc., with PVC/neoprene gasket etc., complete as per the the directions of Engineer-in-Charge.With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) Modi guard |
| 7 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc., with PVC/neoprene gasket etc., complete as per the the directions of Engineer-in-Charge.With float glass panes of 4 mm thickness (weight not less than 10kg/sqm Modiguard |
| 8 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to aluminum windowsusing wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. |
| 9 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, Everite/Hardwyn make for doors including cost of cutting floors as required of existing floor spring embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge with stainless steel cover plate & minium 1.25mm thickness |
| 10 | Providing and fixing aluminium tower bolts, ISI marked, anodised (powder coating not less than 50 micron ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300x10 mm |
| 11 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete |
| 12 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes for AC out pipe to be connected. |