| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(Group A) |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (A) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch |
| 6 | 3 pin 5/6 A socket outlet |
| 7 | Supplying and fixing following12 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 9 | Double Pole |
| 10 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 11 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 12 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 13 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 14 | Supplying and fixing 25 amp, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Supply, Installation, Testing and Commissioning of 1200 mm ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based)for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor singlecorecableandearthingetc.asrequired |
| 16 | Supplying and fixing DP sheet steel enclosure on surface/ recess forDP MCB complete with connections, testing and commissioning etc. as required. |
| 17 | Provinding and fixing of 300 mm exhaust fan double ball bearing of900 RPM Heavy duty motor withlouvers shutters complete with frame in the existing opening, including, making good the damage, connection, testing, commissioning etc. as required. |
| 18 | Providing and fixing18 watt LED surface ceiling light with metal boxincluding making connection, testing etc. complete as required. |
| 19 | PProviding and fixingof 20 watt LED tube 6500 k fittings prewired for LED tube, complete with all accessories and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 20 | Providing and fixing Mirrior Light of 9/10 watt LED Batten 6500 k with Installation testing etc. complete as required. |
| 21 | SITC of vertical wall mounting type electric water heater of capacity 25 Ltr, 2 KW including one pair of flexible PVC connection pipe along with locking nut, bolt and washers etc. complete as required. |