| 1 | Providing, fabrication and erection of following sizes Hot dip Galvanised Iron Heavy Grade ERW Pipes with wrapping, PU painting and necessary fittings like Tees,Elbows (bends), couplings, nipples, reducers, flanges etc. as per the detailed specifications. (Refer Sec V, part-A) |
| 2 | 150 NB |
| 3 | 80 NB |
| 4 | 65 NB |
| 5 | 25 NB |
| 6 | Providing, fabrication and erection of following size Hot dip Galvanised Iron Light Grade ERW Pipes with wrapping, PU painting and necessary fittings like Tees, bends, couplings, nipples, reducers, flanges etc. as per the detailed specifications. (Refer Sec V, part-A) |
| 7 | 65 NB |
| 8 | Providing, fabrication and erection of following sizes of dummy flanges as per the detailed specifications. (Refer Sec V, part-A) |
| 9 | 150 NB |
| 10 | 80 NB |
| 11 | Supply and erection of cast iron gate valve of 150 NB size with OS & Y type raising spindle as per the detailed specifications. (Refer Sec V, part-A) |
| 12 | Supply and erectionof cast iron deluge valve flanged assembly of 80 NB size with wet pilot basic trim assembly as per the detailed specifications. (Refer Sec V, part-A) |
| 13 | Supply and erection of cast iron butterfly valve of 80 NB size as per the detailed specifications. (Refer Sec V, part-A) |
| 14 | Supply and erection of cast iron gate valve of 80 NB size with OS & Y type raising spindle as per the detailed specifications. (Refer Sec V, part-A) |
| 15 | Supply and erection of hot dip GI fabricated Y-strainer flanged end with screen for 80 NB size as per the detailed specifications. (Refer Sec V, part-A) |
| 16 | Supply and erection of Pressure Gauges & pressure switches as per the detailed specifications. (Refer Sec V, part-A) |
| 17 | Supply and erection of deluge valve modular junction box suitable for 3 transformers as per the detailed specifications. (Refer Sec V, part-A) |
| 18 | Supply and erection of electrical release trim assembly for deluge valve with two-way solenoid valve as per the detailed specifications. (Refer Sec V, part-A) |
| 19 | Supply and erection of projectors/nozzles as per the detailed specifications. (Refer Sec V, part-A) |
| 20 | Supply and erection of quartzoid bulb detectors as per the detailed specifications. (Refer Sec V, part-A) |
| 21 | Supply and erection of 80mm dia orifice plate - 3mm thick as per the detailed specifications. (Refer Sec V, part-A) |
| 22 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 23 | MS fabrication1 coat polyurathene primer & 1 coat Polyurathene paint |
| 24 | MS fabrication with Hot dip galvanisation, 1 coat ofMetal coat Etch primer Yellow ,1 coat ofInd Epoxy zinc Phosphate Primer grey and 1 coat of Metal coat PU top coat |
| 25 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 26 | 3/3.5/4core X Upto 25 sqmm |
| 27 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of one number PVC insulated & sheathed Copper Conductor, armoured control Cables of 19 core x 2.5 sq.mm. in excavated trenches direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required..(Note: Cable will be issued free of cost by the department). (Refer Sec VI, Clause No.3) |
| 28 | Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of PVC insulated & Sheathed, armoured control cables of 19 core x 2.5 sq.mm. in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification.(Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 29 | End Termination of the following sizeCopper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable usingSingle Compression, Heavy Duty,Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 30 | 4C x 2.5 Sq.mm including cable gland earthing |
| 31 | 4C x 10 Sq.mm including cable gland earthing |
| 32 | End termination of 1100 Volts Grade XLPE/PVC insulated, control cables of the 19 core x 2.5 sq.mm. using Single Compression, Heavy Duty, Siemens type Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Dowell\"s or equivalent make Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for the completion of the work. (Refer Sec VI, Clause No.10.1). |
| 33 | Supply and installation of the 8 SWG copper wire including excavation and refilling as per the detailed specification. (Refer Sec VI, Clause No.12.8). |
| 34 | Supply and installation of the 8 SWG copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) |
| 35 | Replacement of existing vacuum circuit breaker with new 11KV, 2000 A vacuum circuit breaker as per the detailed specifications. (Refer Sec V, part-A ) |
| 36 | Design, manufacturing, supply and installation of following capacities of manual mechanical ACB handling trolley (Boom type) as per the detailed specifications. (Refer Sec V, part-A ) |
| 37 | 250 kgCB handling trolley |
| 38 | 500 kgCB handling trolley |
| 39 | Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2) |
| 40 | Providing and laying plain cement concrete 1:4:8 using 25mm maximum size graded aggregates including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification for levelling courses in foundation for walls, footings, floor drains etc., encasing pipes and other required works directed by Engineer-in-Charge complete all as per specifications. (Refer Sec V, part-B ) |
| 41 | Providing and laying cast insitu controlled reinforced cement concrete of specified grade at all levels and lifts mentioned below using 20mm maximum size hard granite machine crushed graded stone aggregates including weigh batching, charges for mixing & cost of admixture, mechanical mixing, transporting and placing at all lifts, vibrating, consolidating, curing and finishing smooth of all exposed faces complete for column footings, columns, lintels, sunshades, gutter slabs, beams, slabs, water tank, machine foundation and all other structural elements including dewatering wherever necessary (Formwork and reinforcement will be paid for separately) all as per specification and all as shown in drawings and as directed by the Engineer-in-charge for all insitu item.Note: 1.The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F. (Refer Sec V, part-B ) |
| 42 | M30 grade with 370 kg. of cement per cu.m. of concrete |
| 43 | Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. (The measurement for the formwork will be the actual area of forms in contact with concrete surfaces.) (Refer Sec V, part-B ) |
| 44 | Providing, straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement TMT bars of Fe500 / Fe500D grade steel conforming to IS:1786 \"SAIL or VIZAG or approved equivalent make\" and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks in cement mortar 1:2 and binding wire complete all as per specification and as directed by Engineer-in-Charge at all lifts. Note: The rate shall be including the cost of reinforcement steel. The reinforcement steel will be procured from dealers with a test certificate as approved by the department. (Refer Sec V, part-B ) |
| 45 | Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like MS structural embedment’s/pipe and sleeves/penetration etc. using MS angles, channels, I-sections, plates, tees, flats, rounds, square sections etc. including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of flat oil paint / synthetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge. Note: Lifting device arrangements if any required also arranged by the contractor at his own cost. (Refer Sec V, part-B ) |