| 1 | Dismantling G.I. sheets roofing including ridges hips valleys and gutters etc. and stacking the material within 50 meters lead. |
| 2 | Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mm with cover width of 1020mm including all the accessories (JSW or equivalent make) but excluding the cost of purlins rafters trusses flashings etc. complete as per the directions of the Engineer in charge. |
| 3 | Steel work in built up tubular (round square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL TATA. VIZAG JSW APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc. including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. |
| 4 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 5 | Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 40 kg/ cm2 b)In superstructure upto floor five level. |
| 6 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 7 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 8 | Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead.;With cement mortar 1:4 (1 cement : 4 fine sand) |
| 9 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 10 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 11 | Dismantling doors windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead;Of area 3 sq.m. and below |
| 12 | Rate Analysis;- Providing and fixing anodised aluminium single or double leaf door shutters with heavy sections as specified.+ Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section |
| 13 | Providing and fixing M.S. handles with necessary screws etc. complete.;a)125 mm |
| 14 | Providing & fixing ms. Sliding door bolts bright finished or and black enamelled with nuts and screws etc. complete;a) 300 x 16 mm |
| 15 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with pvc automatic flushing cistern with fittings R.S. or C.I. brackets standard size galvanised steel flush pipe and spreaders with brass unions & G.I. clamps complete including painting of cister and fittings cutting and making good the walls and floors where required.;a)One urinal basin with 5 litres p .v .c. automatic flushing cistern. |
| 16 | Providing and fixing brass bib cock (heavy) of approved quality :a)15 mm nominal bore |
| 17 | Providing and fixing brass stop cock (heavy) of approved quality :a);15 mm nominal bore |
| 18 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 19 | Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering shuttering and finishing in:;All works upto plinth level |
| 20 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete without door :b)75 mm dia |
| 21 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.;b)75 mm dia |
| 22 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design. : |
| 23 | Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :;d)32 mm nominal bore |
| 24 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete without door :a)110 mm dia |
| 25 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand) finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 26 | Providing and fixing 5 litres pvc. Automatic flushing cistern with fittings. |
| 27 | Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore. |
| 28 | Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore: c)45 cm (18â€) length . |
| 29 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 30 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement trenching refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe)e)40 mm nominal outer dia pipes. |
| 31 | Removing and refixing of door/ window shutters paneled or paneled and glazed including replacing of existing hionges chiseling etc complete as directed by Engineer- in – charge;b)Above 1 Sq.m area |
| 32 | Providing & Fixing Alluminium Ridge of approved make adhering to Alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of SS304 grade self tapping fastners to match the Alluminium roofing system & as directed by Engineer in charge complete |
| 33 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.b)500 lit. capacity |
| 34 | Proving and fixing white vitreous china water closet squating (European type w.c. pan) with seat and lid C.P. brass hinges and rubber buffers 10 lts. High level P.V.C.. flushing cistern (of approved make ) with fittings rack bolts 32 mm diameter P.V.C. telescopic flush pipe with fit tings and clamps 25mm P.V.C.. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon. chain and pull complete cutting and making good the walls ad floors where required.;a)W.C. pan with white plastic seat and lid. |
| 35 | Providing and fixing vitrified antiskid tiles (320x320) and 10mm thick tiles in floor treads of steps landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 36 | Providing and fixing rigid PVC S.W.R. (soil waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:;a)110 mm dia |
| 37 | Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door :a)100 mm dia |
| 38 | Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral longitudinal flushing pipe 100mm dia half round channel pvc. Automatic flushing cistern with fittings R.S. or C.I. brackets standard size G.I. flush pipe for back and front flush with stadard spreader fittings G.I. clamps white vitreous china tiling 1200 mm high to front and side walls with white vitreous corners and angles set in neat cement standard urinal C.I. trap 65 mm diameter with vent arm & outlet grating & coupling in c.p. brass complete including painting the cistern & fittings cutting and making good the walls and floors where required.a)Single plate with 5 litres pvc. automatic flushing cistern. |
| 39 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mm sand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required.b)Orissa pattern W.C. pan |
| 40 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson Somany Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours shades except burgundy bottle green black of any size as approved by Engineer-in-charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.b)Wall Ceramic Glazed Tiles : 300 x 450 |
| 41 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.d)Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 42 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.a)15 mm dia nominal outer dia pipes. |
| 43 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. b)20 mm dia nominal outer dia pipes. |
| 44 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement trenching refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe)d)32 mm nominal outer dia pipes. |
| 45 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering shuttering and finishing in:;a)All works upto plinth level |
| 46 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 47 | Refilling the pipeline/foundation trenches plinth sides foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 48 | Centering & shuttering including Strutting Propping & removal of forms for xiii) Suspended floors roofs landings shelves & their supports |
| 49 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering shuttering finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)c)In beams suspended floors roofs having slope upto 15° landings balconies shelves chajjas lintels bands plain window sills staircases upto floor five level |
| 50 | Providing TMT steel reinforcement bars of (SAIL TATA. VIZAG JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 51 | 15mm cement plaster 1: 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 52 | Neat Cement punning |
| 53 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 54 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a)All kinds of soil Please Enable Macros to View BoQ information |