| 1 | Taking down old unserviceable old damagedand S/F new LED Solar street light fitting 40 Watt made with high efficiancy mono crystalline solar pv module uncluding galvanized steel pole in built, lithium ferro phosphate battery, in built NMS technology solar panel, MPPT solar charge controller with dusk down sensor complete all as specified. |
| 2 | Taking down old unserviceable old damagedand S/F new tubular battery ofnot less than 200 AH fully charged 12 volts complete all as specified. |
| 3 | Repair / checking of lithium battery induilded inside the solar light complete and replacement of new lethium battery 12 Volt 24 AH dry type with suitable existing make of solar light the satisfaction of the Engr-in-Charge. |
| 4 | Supply and fixing connectors, converters to make the solar light completely functional connected with battery including any other accessories complete all as specified by engineer in charge |
| 5 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete. |
| 6 | Supply and fixing in repair LED driver for 45 watt LED street light fitting complete all as specified and directed. |
| 7 | Supply and fixing in repair LED Surge Arrester(SRPS 5K 440) for 45 watt LED street light fitting complete all as specified. |
| 8 | Taking down old unserviceable old damaged GI pipe and S/F new GI pipe light grade of size 40mm diafor protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified |
| 9 | Material and labour for Earthing completeusing copper plate 60 × 60 cm × 3.15 mm thick electrode and 20×3mm copper strip as earthing leadand GI protection Pipeas protection 15 mm pipe andalternate 5 layersof charcoal (250 Kg) & salt crystal (200Kg) andtop two inches layerswithBack fillingcompound(100 Kg), all as specified. buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and by means of GI bolts and nuts,check nuts,washers and copper earth strip protected by GI pipe light grade 40 mm bore upto 7.5 mtr and connecting to earth terminal/ test point etc as per site requirement including necessary excavation, earth work in any type of soil PCC (1:3:6) type C1 chamber and 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No. 3 of MES Schedule Part 1 including watering pipe 20 mm dia medium grade with funnel and with mesh , refiling soil all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included in the rate quoted by the contractor. (iii) Beyond 7.5 mtr the copperearth strip20X3mm & GI pipe light grade 40 mm dia shall be measured under relevant item of the schedule. (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. |
| 10 | Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire |
| 11 | Supply and fixing in repairMCB SP 6 to 32 Amp complete all as specified. |
| 12 | Supply and fixing in repair Cable with copper conductor PVC round sheathed (flexible) industrial cable 2.5 sqmm complete all as specified. |
| 13 | S&F as in repairs electric timer control panel, cubical type, for out door use, dust & vermin proof wall/ground mounted made out of CRCA steel sheet with time switches, type 40 Amps 3 pole, 230 volt Analog time switch with complete accessories to fix on panel for switch ON,OFF and control the street light timings including testing complete all as specified and directed. Make :- Havells Cat part IHXSS0312A oror equivalent in make as specified in PS |
| 14 | Supply only LED driver for40/ 45 watt LED street light fitting complete all as specified and directed. |
| 15 | Supply only LED Surge Arrester(SRPS 5K 440) for 40/45 watt LED street light fitting complete all as specified and directed. |
| 16 | Taking down old unserviceable old damagedand S/F new GI pipe light grade of size 40mm diafor protection of UG cable on walls/under floors/road crossings/in trenchesincluding taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete. |
| 17 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE 4 Core16 Sqmm insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts gradeall as specified and as directed. |
| 18 | All as per Sl item No. 17 above but of size 4 core 10 Sqmm |
| 19 | Disconnecting taking out from trenches / pole out lived LT UG cable of size as mentioned in item above.and takingold unserviceable LT UG into credit complete all as specified and as directed by the Engineer-in-Charge complete.Note : Excavation and earth work will be measured and paid separately. |
| 20 | Taking down old unserviceable old damagedand S/F new Post Lentern Light 30 W Fitting with high luminuos efficiancy IP 65 Protected with front toughened glass of capacity with impact and corrosion resistant including all accessories and wiring including dismantiling of old unserviceable fitting Make : C&S Model No LGLC30WHPLED/WF150WHPLED or equivalent in make as specified in PS |
| 21 | Supply, Installation, Testing and Commissioning ofLED bollard with robust design and efficientlight luminarie 10 Watt with IP65 protection all as specified and directed by Engr-in-Charge. Make CG LBLTW-10-WW or equivalent in make as specified in PS |
| 22 | Taking down old unserviceable old damagedand S/F new MCB SP 6 to 32 Amp |
| 23 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc.and getting out for soft/loose soil complete all as specified and directed. |
| 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed. |
| 25 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. |
| 26 | Supply and lay HDPE Pipes PN 10 of 75mm for cable protection,laid complete all as specified and directed. |
| 27 | Taking down old unserviceable old damagedand S/F new weather proof cable junction boxes suitable for outdoor installaions with knockout for cable entrylooping in box PVCwith side dimension155mmx210mmx92 mm comprising of connector -01nos including mounting arrangementsandlugs etc. complete all as specified and as directed. |
| 28 | Taking down old unserviceable old damagedand S/F new, erecting of 5Mtr Height Galvanized Octagonal pole with 65 microns Average thickness of galvanization and Bottom 130mm, top 70mm and base plate 12mm thickness with necessary arrangements. 4 nos of J bolt & nuts supply of 1 no of 16A double pole MCB as incomer with neutral linkcomplete in a proper position complete with CI base plate, finial taper plug, bolts, nuts ,screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed Note:- Earth work shall be measured and paid seperately under the respective item. |
| 29 | Taking down old unserviceable old damagedand S/F new energy saving ,street light fittings LED 40 watts luminaire with high power LEDs and unique flood optics to ensure uuniform distribution and saving upto 50% w.r.t conventional systemand maintenance free system ,including fixing arrangement on pole by providingGI pipe medium grade 25 mm dia 1.5 Mtrin length with suitable size MS Clamp two Nos made out of 25x3 mm FI, prewired all as specified andas directed. |
| 30 | Cement concrete for foundation oftype C1 20 mm graded aggregate 1;3;6 for foundation. |
| 31 | S&F PVC insulated two single core 1.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through andincluding suitable dia non metallic rigidPVC conduitand accessoriescomplete all as specified and as directed.Note : (i)Two run 1.5 Sqmm of single core, one run of 1.5 sqmm earth conductor and PVC conduit will be measured as one RM. |
| 32 | Cutting the road / hard standing for laying of pipes / cable in trenches and making good with PCC 1 :2 :4 Type B1 complete all as specified and as directed . |
| 33 | M&L for earthing as per IS:3043with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to earth using GI earth wire 4mm diaby means of nuts, bolts and washer and check nuts of GI or steel connected to main DB/Panel/equipments including necessary earth work and excavation and including PCC chamber with 1:3:6 type C-2 and cover using steel sheet 3 mm thick with handle and frame of angle iron 25x25x5mm, GI medium grade 15mm bore pipe for watering common salt charcoal, funnel wiremesh and earth test point terminal block and testing on completion all as specified and or shown in electrical plate No 3 of SSR Pt-I and testing of earth resistance as required.Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately). |
| 34 | M&L for Earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wirefixed to wall on batten or recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required |