| 1 | Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan,control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts,door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator,and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC cardof stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts ,fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber matandair freshner at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfacesand liftmachine and all equipmentheld in machine roomand rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of liftand complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed. (for Item No 01 to 2.00). (a) 8 Ps Lift (554 Kg)capacity in R-40 bldg (G+13 Storey)(Total 02 Nos) of Lifts |
| 2 | (b) 13 Ps Lift (884 Kg)capacity in R-40 bldg (G+ 13 Storey) (Total 02 No of Lifts) |
| 3 | Disconnecting and taking out unserviceable COP assembly for G+5/G+14 storey building, supply and fix new car operating panel assembly completed with illuminated push button for floor position alarm, non stop door open , door close, cabin fan, cabin light stop, attend out key etc with direction indicator,with LED displey with CPI card of stainless steel face plate in and including necessary wiring for laminating push button of each floors and cutting wall, making good disturbed surface with machinary work to complete all as specified and directed. |
| 4 | Supply and fix in replacementcabin fan non oscilating type axial flow, single speed 300mm sweep, 240 volts ISI mark with grill complete all as specified anddirected. Make :- Exsisting make |
| 5 | Supply and fix in replacementdoor drive unit with motor on car top with VVVF of 1 HP capaicity all as specified anddirected . Make : As approved. |
| 6 | Dismantling and taking out unserviceable safety edge of anytype supply and fixing full beam infrared sensor upto full length of car doors (2.00 mtr)complete all as specified and directed. Make : As approved |
| 7 | Supply and fix in repair Emergency alarm with complete accessories including rechargeable batteries alongwith box including connecting cables for G+13 storey building all as specified and directed . |
| 8 | Supply and fix in replacementmain steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin andrope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps,nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 8/13 /GoodsLift, G+5/G+6/G+16 Storey buildings.Make : As approved. |
| 9 | Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing CAN BAS Integrtaed drive suitable for 13 Ps lift G+14 storey building complete with all electric connection. Complete all as specified and directed. |
| 10 | Disconnecting and taking out old/unserviceable Governer rope of size 8 mm dia(8/19 Construction) ungalvanised including necessery connection with pully in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13 Ps lifts Complete all as specified and directed. |
| 11 | Disconnecting and taking out unserviceable ARD and repair of ARD for proper operation including necessery wiring with machine and controller consisting of Replacement of PCB Card, relay with control wiring for G+14 storey building.Complete all as specified and directed. |
| 12 | Supply and fix in replacement of sealed maintenance free batteries ( Set of Four) each of 12 volts, 18 AH ( Two year maintenance free) Make :-As approved Complete all as specified and directed. |
| 13 | Supply and fix in replacementpush button box along with illuminated call button with digital arrow indicationwith controll wiring, for G+13 storey building Complete all as specified and directed. |
| 14 | Supply and fix in replacementof OSG Pully both top and bottom for 08ps/13 Ps/Goods Lift Complete all as specified and directed.. |
| 15 | Supply and fix in replacement ofmain pulley of 4/5/6 grooves suitable for existing motor andfixing of existing rope complete as specified and directed . |
| 16 | Supply and fix in replacementof aluminium covered wire wound dynamic breaking resistor to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for 11.0KW/15HP motor. Complete all as specified and directed. |
| 17 | Supply and fix in replacement of sealed maintenance free batteries ( Set of Four) each of 12 volts, 18 AH ( Two year maintenance free) Make :-As approved Complete all as specified and directed. |
| 18 | Supply and fixing in repairs, commissioning and testing ARD system suitable for upto 15 kW motor including wiring with connected items in existing G+14 Storey building suitable for8PS/ 13PS/ Goods lifts ofMAKE-THYSSEN KRUUP 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery) to be compatible with the existing motor of any make and capacity and controller systemcomplete all as specified and directed by Engineer-in-Charge for the following lifts. (for item No 17.00 to 18.00)(a) 8 PS lift (544 Kg) capacity, , installed in G+14 storey building No R-9,R-10,R-24 (Total 03 No lift) . |
| 19 | Ditto all as per Item No 18.00 above but 13 Ps lifts (884 Kgs ) capacity, installed in (G+14) storey building Nos R- 28,R-28,R-32(Total 03 Nos lift).Complete all as specified and directed. |
| 20 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+ 6/G+14 Storey building 8PS/13PS/Goods lifts (MAKE-Exising at bldg ) 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery, Make Exide/Amaron) to compataible with the existing motor of any make and capacity and controller system for 13 Ps lifts (884 Kgs ) G + 14 storeybldg(G+14) R- 32,R-34(Total 02 Nos lift).complete all as specified and directed. |
| 21 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+14 Storey building 8PS/13PS/Goods lifts (MAKE-Existing at Bldg) 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery, Make : as approved ) to compataible with the existing motor of any make and capacity and controller systemcomplete all as specified and directed (for Item Nov21.00 to 23.00) . (a )8 PS (544 Kg) capacity G+14 storeyR-12 , (Total 01 Nos lift) complete all as specified and directed by the Engineer-in-Charge |
| 22 | Ditto all as per Item No 21.00 above but 13 Ps lifts (884 Kgs ) capacity in bldg(G+14) R- 39(B), R- 39 (A) (Total 02 Nos lift). |
| 23 | Ditto all as per Item No 21.00 above but Goods Lift29 Ps ( 2000 Kgs) capacity in Bldg ( G+14) R-28,R-32 ( Total 02 Nos lift) |
| 24 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+14 Storey building 8PS/13PS/Goods lifts (MAKE-Existing make at Bldg) 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery,( Make : As approved ) to compataible with the existing motor of any make and capacity and controller systemcomplete all as specified and directed .for the following lifts. (for iem No .24.00 to 26.00), (a) 8 PS (544 Kg) capacity G+14 storeyR-18 , (Total 01 Nos lift) complete all as specified and directed . |
| 25 | Ditto all as per Item No 24.00 above but 13 Ps lifts (884 Kgs ) capacity in bldg(G+14) R-9,R-10,R-15,R-16,R-20,R-21,R-24,R-27 (Total 08 Nos lift). |
| 26 | Ditto all as per Item No 24.00 above but Goods Lift29 Ps ( 2000 Kgs) capacity in Bldg ( G+14) R16,R-20,R-21 ( Total 03 Nos lift) |
| 27 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+14 Storey building 8PS/13PS/Goods lifts (MAKE-Existing at Bldg) 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery, Make : as approved) to compataible with the existing motor of any make and capacity and controller systemcomplete all as specified and directed by Engineer-in-Charge for the following lifts.(for iem No .27.00 to 28.00) (a) 8 PS (544 Kg) capacity G+14 storeyAR,AQ, (Total 02 Nos lift) complete all as specified and directed . |
| 28 | Ditto all as per Item No 27.00 above13 Ps lifts (884 Kgs ) capacity in bldg(G+14) AR,AQ, (Total 02 Nos lift). |
| 29 | Replacement of unserviceable ARD control system and commissioning and testing of newARD system suitable for upto 15 KW motor including wiring with connected items in existing G+14 Storey building 8PS/13PS/Goods lifts (MAKE-Existing at Bldg ) 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos two year Maintenance free battery, Make As approved ) to compataible with the existing motor of any make and capacity and controller systemcomplete all as specified and directed . for 13 Ps lifts (884 Kgs ) capacity in bldg(G+14) RIS (Total 01 Nos lift). |
| 30 | M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected to lifts including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plateincluding testing on completion.complete all as specfied and directd. |
| 31 | Supply and laying aluminimum strip of size 25x3mm from test point to lift machine room over the porcelain insulator provided at interval of 50 cm in such a way that aluminimum strip should not touch to the wall and their should not be sharm bends/kinks etc. complete all as specified and directed. |
| 32 | Overhauling Complete lift machine hoist way and indication motor with capacity from 7 HP to 15 HP both by opening of Gear removing old dirty oil, cleaning & replacing of new gear oil refitting of the same with new packing & adjustment of thrust bearing and keeping it into perfect working order, opening of hosit way machine by taking the main pully and divereter pully and complete refixing after overhauling Complete all as specified and directed. |
| 33 | Material & Labourfor repairs/ Servicing to Existingpanels Indoor type of each Machine room of bldg by taking shut down from appropiate authority including checking loose connections and cleaning inside/out side all connection,replacing old/rusted cable glands,thimbles and lugs as per the size of existing cable, repair to broken /hanging doors, glas and cover bolts etc to make it servicable and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. Note :- The tenders quoted rate per unit shall deemed to be inclusive of taking out burntMCB SPN/MCCB/Voltmeter/ Ampiermeter/LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule.(i) Cleaning inside the panel and all incoming and out going including MCCB/MCB SPNthorouly with help of Vaccum Cleaner.(ii) Checking the loose connections of incoming and out going cable/wire and rectifify the same. |
| 34 | S&F in repair,MCCB 63 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu. in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, complete all as specified and directed. |
| 35 | S&F in repair,MCCB 100 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu. in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, complete all as specified and directed. |
| 36 | S&F in repair,MCCB 160 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu. in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, complete all as specified and directed. |
| 37 | M&L scrapping old worn out paint from complete indoor type meter cabin panels and painting with one coats of synthetic enamel paint (incl front door in side and indl compartment outer side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board and replacement of brocken glass of any size Complete all as specified and directed. |
| 38 | S&F in repair,MCB SPN, 32 Amp, 10 KA, 230 Volt. connection complete and testing after completion, complete all as specified and directed. |