New and Renewable Energy Boards / Undertakings / PSU Closing in 0 days TDR #53321240

Bids Are Invited For Construction Of Morcha, Pathway, Repairing And Painting Of Existing Structure At Jharia Magazine Total Quantity : 12398

Issued by Boards / Undertakings / PSU · East Singhbum, Jharkhand
Tender Value
18.49 Lakhs
Estimated cost
Bid Submission
27 Jan 2026
0 days left
EMD
18492
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Singhbum → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are Invited For Construction of Morcha, Pathway, Repairing and Painting of existing structure at Jharia Magazine-1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto 1.5m: All kinds of soil 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 3 Return earth filling by available excavated earth (excluding rock) or locally available sand in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming(allow for breading up lumps, shrinkage etc.) watering lead upto 50 metre and lift up to 1.5 m complete as directed by the Engineer-in-charge 4 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. Providing and laying plain cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate 20mm nominal size )in foundation, plinth wherever necessary including desalinating, finishing, curing etc. per specification all complete but centring and shuttering etc. Providing and laying reinforced cement concrete work 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate using 20 mm down screened and washed) including machine mixing, placing in position and mechanically vibrating in footing, column, plinth beam up to plinth level and like including preparing of the top surface finishing curing ecomplete in all respects as per specification and direction. Providing and laying reinforced cement concrete work 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate using 20 mm down screened and washed) including machine mixing, placing in position and mechanically vibrating in beams, suspended floor landing, balconies, lintel etc.to any floor and any where and like including preparing of the top surface finishing curing complete in all respects as per specification and direction. Hire and labour charges for providing and fixing straight shuttering for concrete works to anywhere at any floor (including staging) including strutting, propping etc. and removal of form or striking out after completion of works as directed and specified by the Engineer-in-charge. a) Foundations, footings, bases of columns plinth beam etc b) Suspended floors, roofs, landings, balconies, shelves etc. c) Lintels, beams, cantilever etc. Steel reinforcement (for reinforced cement concrete work) including transporting, decoiling, straightening, derusting, placing, cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection including removal of loose rust and applying a coat of cement wash if necessary complete in all respects as per drawing and at any floor as directed. 3500.00 Brick work with bricks of class designation 75 in superstructure with cement mortar 1:6 (1 cement : 6 course sand) including all materials, labour, scaffolding, racking out joints, curing as per specification and direction of the Engineer-in-charge. 12 mm cement plaster of mix : 1: 4 (1 cement : 4 coarse sand ) 250.00 Neat cement punning 125.00 15 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 16 Finishing walls with water proofing cement paint of required shade : Old work (one or more coats @ 2.20 kg/10 sqm) complete. 17 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 18 Supplying and Painting with synthetic enamel paint/ aluminum paint of approved brand and manufacture Two or more coats in new work..Two or more coats in new work. 19 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 21 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm 22 Providing and fixing anodized aluminum tower bolt including necessary screws etc. complete.250 X 10mm 23 Providing and fixing anodized aluminum door handle including necessary screws etc. complete.a) 125mm 24 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 25 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 26 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter Providing and fixing of glass panes, with putty and nails wherever necessary: Glass panes 4mm thick. Grading of roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12mm nominal size) in appropriate proportion. Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 31 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Corrugated serrated adjustable ridges 32 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) 33 Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film.34 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 35 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 36 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and ixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire 37 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron „Y‟ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. Wiring for light point/ fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmx75mm) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Supply and fixing of LED Bulb, W-14 or above of reputed brand direction of EIC. Supplying and fixing 5A to 32A rating, 240/415V, 10KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles the existing MCB DB complete with connections, testing and commissioning etc. As required. Single pole 6A Providing and fixing of Crompton Gleam 70 Watt Outdoor Waterproof LED Flood Light | Wide Angle Beam| (Cool Day Light 6500K) Supplying, Fitting and Installing Electric wall mounted Fan 300 mm. Total Quantity : 12398

BOQ

Sl. No. Item TitleItem Description
1Item1Item Description1
2Item2Item Description2
3Item3Item Description3
4Item4Item Description4
5Item5Item Description5
6Item6Item Description6
7Item7Item Description7
8Item8Item Description8
9Item9Item Description9
10Item10Item Description10
11Item11Item Description11
12Item12Item Description12
13Item13Item Description13
14Item14Item Description14
15Item15Item Description15
16Item16Item Description16
17Item17Item Description17
18Item18Item Description18
19Item19Item Description19
20Item20Item Description20
21Item21Item Description21
22Item22Item Description22
23Item23Item Description23
24Item24Item Description24
25Item25Item Description25
26Item26Item Description26
27Item27Item Description27
28Item28Item Description28
29Item29Item Description29
30Item30Item Description30
31Item31Item Description31
32Item32Item Description32
33Item33Item Description33
34Item34Item Description34
35Item35Item Description35
36Item36Item Description36
37Item37Item Description37
38Item38Item Description38
39Item39Item Description39
40Item40Item Description40
41Item41Item Description41
42Item42Item Description42
43Item43Item Description43
44Item44Item Description44
45Item45Item Description45
46Item46Item Description46
47Item47Item Description47
48Item48Item Description48
49Item49Item Description49

AI Tender Summary

OUR REF NO 53321240
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 18.49 Lakhs
LAST DATE 27-01-2026
Authority
Authority Name Uranium Corporation Of India Limited
Work Description Bids Are Invited For Construction of Morcha, Pathway, Repairing and Painting of existing structure at Jharia Magazine-1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto 1.5m: All kinds of soil 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 3 Return earth filling by available excavated earth (excluding rock) or locally available sand in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming(allow for breading up lumps, shrinkage etc.) watering lead upto 50 metre and lift up to 1.5 m complete as directed by the Engineer-in-charge 4 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. Providing and laying plain cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate 20mm nominal size )in foundation, plinth wherever necessary including desalinating, finishing, curing etc. per specification all complete but centring and shuttering etc. Providing and laying reinforced cement concrete work 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate using 20 mm down screened and washed) including machine mixing, placing in position and mechanically vibrating in footing, column, plinth beam up to plinth level and like including preparing of the top surface finishing curing ecomplete in all respects as per specification and direction. Providing and laying reinforced cement concrete work 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate using 20 mm down screened and washed) including machine mixing, placing in position and mechanically vibrating in beams, suspended floor landing, balconies, lintel etc.to any floor and any where and like including preparing of the top surface finishing curing complete in all respects as per specification and direction. Hire and labour charges for providing and fixing straight shuttering for concrete works to anywhere at any floor (including staging) including strutting, propping etc. and removal of form or striking out after completion of works as directed and specified by the Engineer-in-charge. a) Foundations, footings, bases of columns plinth beam etc b) Suspended floors, roofs, landings, balconies, shelves etc. c) Lintels, beams, cantilever etc. Steel reinforcement (for reinforced cement concrete work) including transporting, decoiling, straightening, derusting, placing, cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection including removal of loose rust and applying a coat of cement wash if necessary complete in all respects as per drawing and at any floor as directed. 3500.00 Brick work with bricks of class designation 75 in superstructure with cement mortar 1:6 (1 cement : 6 course sand) including all materials, labour, scaffolding, racking out joints, curing as per specification and direction of the Engineer-in-charge. 12 mm cement plaster of mix : 1: 4 (1 cement : 4 coarse sand ) 250.00 Neat cement punning 125.00 15 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 16 Finishing walls with water proofing cement paint of required shade : Old work (one or more coats @ 2.20 kg/10 sqm) complete. 17 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 18 Supplying and Painting with synthetic enamel paint/ aluminum paint of approved brand and manufacture Two or more coats in new work..Two or more coats in new work. 19 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 21 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm 22 Providing and fixing anodized aluminum tower bolt including necessary screws etc. complete.250 X 10mm 23 Providing and fixing anodized aluminum door handle including necessary screws etc. complete.a) 125mm 24 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 25 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 26 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter Providing and fixing of glass panes, with putty and nails wherever necessary: Glass panes 4mm thick. Grading of roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12mm nominal size) in appropriate proportion. Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 31 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Corrugated serrated adjustable ridges 32 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) 33 Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film.34 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 35 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 36 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and ixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire 37 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron „Y‟ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. Wiring for light point/ fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmx75mm) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Supply and fixing of LED Bulb, W-14 or above of reputed brand direction of EIC. Supplying and fixing 5A to 32A rating, 240/415V, 10KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles the existing MCB DB complete with connections, testing and commissioning etc. As required. Single pole 6A Providing and fixing of Crompton Gleam 70 Watt Outdoor Waterproof LED Flood Light | Wide Angle Beam| (Cool Day Light 6500K) Supplying, Fitting and Installing Electric wall mounted Fan 300 mm. Total Quantity : 12398
Basic Detail
Tender No GEM/2026/B/7076810
Bidding Type Tender
Location
City East Singhbum
State Jharkhand
Key Dates
Publish Date 06 Jan 2026
Submission Date 27 Jan 2026
Open Date 27 Jan 2026
Finance
Tender Value 18.49 Lakhs
Tender Fee Ref. Documents
EMD 18492
Exemption Not Available
Document List
scope_of_work_and_boq_2026-01-06-12-05-22_033a040b5190b08383fc56602288055e.pdf
8800797_Boq_0.xlsx
0287c253-a907-45c0-97d5-6ea8622b4d58.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

scope_of_work_and_boq_2026-01-06-12-05-22_033a040b5190b08383fc56602288055e.pdf

xlsx

8800797_Boq_0.xlsx

pdf

0287c253-a907-45c0-97d5-6ea8622b4d58.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders