| 1 | Formwork to sides and soffits of floor or roof beams haunchings, girders, bressummers, lintals, bands,chajjas, cantilevers, shelves including supports overhangs, etc also splays between floor and beams etc. |
| 2 | M&L for Reinforced cement concretenominal mix Type B1, 1:2:4, (20mmgradedaggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed. |
| 3 | S&F for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 4 | S&F for TMT Mild steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 5 | S&F for TMT Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 6 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles |
| 7 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius in cement mortar 1:6. complete all as specified & directed. |
| 8 | M & L for brick work (except bricks re use obtained from dismantle) with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius in cement mortar 1:6. complete all as specified & directed. |
| 9 | M&L for Rendering 15 mm thick(1:4) on fair faces of brick work or concrete surfaces be finished even and smooth (without using extra lime or cement) complete |
| 10 | S&F Angle iron fencing post and struts including cutting tops to shape as directed drilling holes, notching for wire etc, flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 including round bars etc complete all as spd &directed |
| 11 | Dismantle wrought iron or mild steel work of any description not otherwise provided for |
| 12 | Fabrication only obtained from dismantleAngle iron fencing post and struts including cutting tops to shape as directed drilling holes, notching for wire etc, flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 including round bars etc complete all as spd &directed |
| 13 | M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of primer complete all as specified and as directed. |
| 14 | .M & L for erecting of600 mm dia punched tape concertina coil / Razor wire concertina coil having 50 Nos spiral turns, (weight shall not be less than 6.0 Kg) and one coil (i.e 50 spiral shall not be stretched more than 6.0m), tied with GI staples and GI clips to retain in horizontal position & including necessary bolting or tied to GI birbed wire or angle iron etc., and fixed in angle iron brackets on compound wall with and including using necessary scaffolding along the length of wall complete all as specified and directed. |
| 15 | Fixing only concertina coil obtained from dismantle & including necessary bolting or tied to GI birbed wire or angle iron etc., and fixed in angle iron brackets on compound wall with and including using necessary scaffolding along the length of wall complete all as specified and directed. |
| 16 | Dismantle of concertina coil any typecomplete all as specified and directed. |
| 17 | S&F for Galvanised. 2 strand, steel barbed wire 2.mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed |
| 18 | S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or stel pins, etc. as directed (each line wire to be measured) |
| 19 | Preparation of new or previous untreated steel and iron Surfaces of any description, over 10 cm in width or girth and applying two coat if synthetic enamel paint over a coat of red oxide zine chrome primer complete as specified. |
| 20 | M&L for Pre- painted galvatume aluminum zinc coating GI based plainsteel sheet 0.50mm thick of redcolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 21 | S&F MS Framed work such as grills gratings, door and cooler stand, ladders etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars confirming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 22 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick, including removing rubbish off the premises complete all as directed |
| 23 | M&L for preparation of existing treatment from old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 24 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded Portionand making good disturbed area complete all as specified. |
| 25 | Dismantling galvanisedbarbed wire fencingany size, |
| 26 | Excavation in post holes (or similar holes ) each n exc 0.5 cu m getteing out as soft /loose soilrerurning filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25 cm complete all as specified. |
| 27 | M&L for PCC 1;3:6 type C-2 using 40 mm graded stone crushed aggregate as in foundation & mass concreteetc complete all as specified. |
| 28 | S&FMild steel screw bolts (machine made) dia of neck 5 to 10 mmwith hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed |
| 29 | S&F mild steel round bars 10mm dia cut to length, bent to shape as required and fixed in fencing confirming to Fe 410-Wor Fe 290 completeall as specified. |
| 30 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 31 | supply only MS galvanised chain link any size ofmesh as in fencing with complete all as specified |
| 32 | M&L for Preparing new steel surfaces of any description .n. exc 10 cm width or girth and applying two coats of synthetic paint over and including one coat of red oxide primer complete all as directed |
| 33 | Surface excavation in soft or loose soils n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out. |
| 34 | Excavation of trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation etc or for sharts, wells cessipts, manholes, pier holes etc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 35 | Excavating over areas in soft or loose soil, n exc 1.5 m deep and getting out. |
| 36 | Returning, filling inincluding spreading, leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all complete all as directed. |
| 37 | Removing excavated material to a distance n.exc 50M and depositing where directed at a level n.exc 1.50M above the starting point. complete all as specified and directed |
| 38 | M&L for Cement concrete Type B2 1:2:4 (12.5mm graded aggregate) in foundations, filling and mass concrete. |
| 39 | M&L for PCC Nominal Mix Type B0 1:2:4 (12.5mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 40 | M&L for PCC Nominal Mix Type B0 1:2:4 (12.5mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 41 | M&L for Cement concrete Type B2 1:2:4 (20mm graded stone aggregate) in surface channels and drains. |
| 42 | Forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 43 | M & L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling as mass concrete, complete all asspecified and as directed. |
| 44 | M & L forbrick work with sub-class \"B\" bricks, straight or curved on plan exc 6.0 metre mean radius as wall built in cement & sand mortar 1:6, complete all as specified and as directed. |
| 45 | M&L for RCC Nominal Mix Type B0 1:2:4 (12.5mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 46 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. |
| 47 | Formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping). |
| 48 | M&L for preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of white wash, complete all as specified and as directed. |
| 49 | S&F of Galvanized steel water tubing medium grade of 15mm bore with & including all fittings fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 50 | Supplying & fixing steel tubing ,galvanised, medium grade 32 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed. |
| 51 | Supplying & fixing steel tubing ,galvanised, medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed. |
| 52 | S&F Gun matel, globe or gate valves 20 mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 53 | S & F2000 ltrISI marked three layer, white colour, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) with thread type cover and fixed with screw hoisted and fixed in position & including20 mm brass ball valvecomplete all as specified and as directed. |
| 54 | M&L for Precast cement concrete type B-1 (1:2:4) using 20mm graded aggregate in cover slabs (in drain etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces. |
| 55 | M&L for mild steel deformed or twisted bars 6-8mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hoop for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips . |
| 56 | M & L for PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in surface channels and drains. complete all as specified |
| 57 | Extra for fair finished to drain or channel 30cm inner girth in cement concrete using extra cement incl.moulds,forms,milres/stripped ends etc.complete all as specified. |
| 58 | M&L for providing, cement concrete Type C1 ( 1:3:6 )using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 59 | S&F of rolled mild steel Fe-290 (Gde E-165) in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated). |
| 60 | S&F of perforated mild steel Plates Fe-290 (Gde E-165) (plain or chequered), 10mm thck, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. |
| 61 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade B. |
| 62 | M&L Hardcore Broken stone guage not exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface.Broken stone or Boulders |
| 63 | M&L for formwork of flat surface to side of pillars, post, struts, piers, columns and stanchionsr and similar work complete all as specified & directed. |
| 64 | M&L for reinforced cement concrete (design mix) M-25 (20mmgradedaggregates) in foundation, raft, plinth beam, bases of column and mass concretecomplete all as specified & directed. |
| 65 | M&L for reinforced cement concrete (design mix) M-25 (20mmgradedaggregates) in columns, pillars, piers, posts and struts complete all as specified & directed. |
| 66 | M&L for 20 mm thick Graniteslab work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like laid over and including 15mm thick screed bed in cement mortar 1:4 and pointing in white cement (1:2 )using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 67 | S&F for MS framed work as in doors or gates of angle or other sections with gusset plate rails braces etccomplete drilled for fixing of steelsheetingor other covering to doors etc to be prepared for hanging or sliding with and including either hooks and pintel hinges or steel hanging door etccomplete all as specified and as directed. |
| 68 | M&L for plates / sheet fixed in wall clading steel gate and similar work cut to size holes punched incl round headed scre clout nail or rivet steel framing joint with riveted or welded seams complete all as specified and as directed. |
| 69 | M & L for Point wiring for One light/ fan point controlled by one way switch 5 amp with 1.5 Sqmm (nominal area) single core PVC insulated Sheathed (FRLSH) cable, multi-stranded, copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall incl cutting & chases( making good all to the disturbed surfaces as per existing)and modular flush metal boxes including cover plate with framefor mounting modular switches, sockets, regulators,socket etcincluding earth wire ofPVC insulated (FRLSH) copper conductor multistrandedof 1.5Sqmmsize in green colour complete all asspecified in current SSR Part-I & II & directed by the Engineer-in-Charge |
| 70 | All as per item No. 11600 butfor One 3 pin 5 Amps socket point controlled by one way switch on independent board. |
| 71 | S&F Modular switch 6 Amps single pole one-way, 1 Module complete. |
| 72 | S&F Modular socket2-in-1, 5 pins 6 Amps, combined 2 Module complete. |
| 73 | Supply & fixing indoor decorative ultra slim surface /Wall mounted LEDbatten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts, co- related colour temperature (CCT) of 6500K, >100 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F Base Frame Mounted 2 HP, 3 phase motorized 40 bar car washer pump complete with Triplex plunger bare pump with discharge 15 LPM at 35 Bar, electric motor 2 HP, 3 phase, 1450 RPM mounted on MS Fabricated base frame, suitable pulley & Belts with safety gurad, suction filter for positive suction, Glycerin filled pressure gauge dia 2.5 inch 70 Bar, pressure regulating valve, trigger operated gun, High pressure straight jet nozzle, suction hose pipe, bypass hose pipe, high pressure rubber hose pipe - 10 mtr complete all as specified and directed. |
| 75 | Supply and Install Factory assembled hut type double door type with cable alloy outdoor LT panel suitable for 3 phase, fabricated out of CRCA sheet 3.15mm thick MS sheet tapered, drip proof, top extended 100 mm on all sides including MS angle iron base frame of size 50x50x6mm thick duly welded with the following mountings/accessories & having individual compartment for switch gear connected and inter conneciton and painting with epoxy based primer and two coats of synthetic enamel paint withcontrol wiring and locking arrangement etc complete all as specified and directed with PCC Foundation work with following specification(a) Busbar aluminium - 200 Amps -04 Nos (a) MCCB 63 Amp, 4 pole, 16 KA-01 Each (01 In-coming)(b) Digital Amp meter (0-250) -01 Each(c) Digital Volt meter (0-100)-01 Each(d) RYB Indicator -01 Set(e) MCB 32 Amp, 2 pole, 16 KA-02 Each (01 outgoing)(f) Starter with single phase preventor, 3 phase, for washing pump 2 HP-01 Nos. |
| 76 | Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor cable size 16 sq mm 4 core laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panelfrom pole / Main Panel Box and testing complete all as specified and directed. Note:- HDPE pipe rate shall be deemed in quoted rate above. |
| 77 | M&l for Earthing complete with GI earthplate 600mm x 600mm x 6.3 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI strip 25 x 4mm asearth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling incl necessary excavation and earth work complete all as specified and as directed. |