| 1 | M&L for Routine maintenance of 20 to 40KVA DG Set consisting of normal repairs with periodical routine maintenance and testing of DG set complete of following ( i,e. Engine, alternator etc under GE 867 EWSall including consumables itemslike cotton wastecloth kerosene oiletc. Maintenancewill be carried out as and when ordered in writing by Engineer-in-Chare of maintenance, complete all as specified and as directed. schedule.(i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy.(iii)Changing of water filter. (iv) Making up coolant.(v) Clean alternator winding in position by forced air and internal surfaces lubricate.(vi) Tightining of all nut bolts. (vii) Greasing of all points.(viii) Checking of any leaking in fuel & oil lines.Note - Accessories / spares/ new engine oilrequiredforreplacementwillbemeasuredandpaidseparately under respective items of schedule ‘A’ as supply only. |
| 2 | M&L for Routine maintenance of 7.50 to 15 KVA DG Set consisting of normal repairs with periodical routine maintenance and testing of DG set complete of following ( i,e. Engine, alternator etc under GE 867 EWSall including consumables itemslike cotton wastecloth kerosene oiletc. Maintenancewill be carried out as and when ordered in writing by Engineer-in-Chare of maintenance, complete all as specified and as directed. schedule.(i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy.(iii)Changing of water filter. (iv) Making up coolant.(v) Clean alternator winding in position by forced air and internal surfaces lubricate.(vi) Tightining of all nut bolts. (vii) Greasing of all points.(viii) Checking of any leaking in fuel & oil lines.Note - Accessories / spares/ new engine oilrequiredforreplacementwillbemeasuredandpaidseparately under respective items of schedule ‘A’ as supply only. |
| 3 | Supply only new Engine oil 15 W 20, complete all as specified and as directed.Make : HP/BP/Indian |
| 4 | Supply only fuel filter suitable for 20 to 40KVA DG Set, complete all as specified and as directed. |
| 5 | Supply only fuel filter suitable for 7.5 to 15 KVA DG set, complete all as specified and as directed. |
| 6 | Supply only lubricant oilfilter suitable for 20 to 40KVA DG Set, complete all as specified and as directed. |
| 7 | Supply only lubricant oilfilter suitable for 7.5 to 15 KVA DG set, complete all as specified and as directed. |
| 8 | Supply only air filter element suitable for 20 to 40KVA DG Set, complete all as specified and as directed. |
| 9 | Supply only air filter element suitable for 7.5 to 15 KVA DG set, complete all as specified and as directed. |
| 10 | Supply & top up water coolant in radiotor of DG set of any capacity, complete all as specified and as directed.Make : TVS Girling/volvo line or of equivelent make |
| 11 | Cleaning of the fuel tank of DG sets of 40/30/20/7.5 KVA capacity after decaning the diesel,after through cleaningwith kerosene oilincluding replacement oflevel indicator pipe, complete all as specified and as directed. |
| 12 | M & L for cleaning/washing the radiator, complete all as specified and as directed. |
| 13 | M&L for replacement of Radiator hose Kit suitable for7.5 to 40KVA DG set KVA DG set, complete all as specified and as directed. |
| 14 | M&L for replacement of Fan belt suitable for 20 to 40KVA DG Set, complete all as specified and as directed. |
| 15 | M&L for replacement of Fan belt suitable for 7.5 to 15 KVA DG set, complete all as specified and as directed. |
| 16 | M&L for replacement of Dynamo 12 Volts, 35 amps as per existing in 40 KVA DG set, complete all as specified and as directed. |
| 17 | S & F for selector switch/ rottary switch as per existing, complete all as specified and as directed. |
| 18 | Supply and fix in replacement of Lid acid battery 12 volt 90 AH suitable for 50/ 40 KVA DG set, complete all as specified and as directed.Make : Amaraon/Exide/SF |
| 19 | M&L for servcing the starting panelof DG Set, cleaning and adjusting the time setting, cleaning and tightening the lose connection of contactor, timer, HRC fuse ammeter, voltmeteretc and making for smooth functioning of the starting operationof 7.5 to 40 KVAcap, complete all as specified and as directed. |
| 20 | Material and labour for Load balancing of LT panel connected in DG set in all three phases of all outgoings, complete all as specified and as directed under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load.b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit. c) Take the building wise load on the panel and make the load balance at bldg end. |
| 21 | Material and labour for Reconditioning and reconnecting of AMF panel in Various type of DG set including removing of rust particles ad corrotion/ carbon from panel connected items likepower contactor, CTs, MCCB/ MCBs, complete all as specified and as directed. |
| 22 | Supply and fix in Replacement of Off load Change over switch 4 pole, 415 Volt, 250 Ams capacity including all incomming and outgoing electric connectios, complete all as specified and as directed. |
| 23 | M&Lsubmain wiring with two single core PVC insulated,unsheathed,stranded copper conductor cable (FRLS), 1100 volts gradeof size 10 Sqmm (nominal area) each and one single core 10 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping, complete all as specified and as directed.NOTE: (i)Rates for PVC casing capping with accessories are deemed to be included in the unit rate. |
| 24 | Supply install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15 mm CRCAMS sheet having one side openable hinged door shuter with looking arangement/provn of two nos 80cm long 40x40x6mm anlge iron legs welded and 04 nos copper bus bar of 200Amp rating provn of one MCCB 4 pole 160 Amp 25 KA for controlling Electric supply complete erracted on ground with necessary PCC (1:3:6) type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbleswith framework 1000mm (W) X 600mm (H) X 300mm (D), complete all as specified and as directed. |
| 25 | Supply and fix sheet metal enclosure double door 4 way DBs SPN, 240V with 200 Amps rated bus barsdouble door complete in and including of existing electric connection/ circuit, complete all as specified and as directed. |
| 26 | S&F TPN DB with suitable for TPN MCBincomer, double door (IP-54), 6 Ways, built- in 200 Ampsbusbar for neutral linkcomplete suitable for 415 Volts, AC, 50 Hz, complete all as specified and as directed. |
| 27 | S&F Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door, built in 200 Amps bus bar complete suitable for 240 Volts, AC, 50 Hz complete in and including of existing electric connection/ circuit, complete all as specified and as directed. |
| 28 | M&L in replacement of u/s MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA, complete all as specified and as directed. |
| 29 | S&F in repairs, MCCBs 63A, 415V AC, 16KA, 4 Pole, thermal magnetic, complete all as specified and as directed. |
| 30 | S&F in repairs, MCCBs 100A, 415V AC, 16KA, 4 Pole, thermal magnetic, complete all as specified and as directed. |
| 31 | Supply and fix MCB,Tripple Pole & Neutral, 40-63 Amps, 415 volts, 50 Hz, 16kA, complete all as specified and as directed. |
| 32 | Supply and fix MCB,Tripple Pole63 Amps, 415 volts, 50 Hz, 16kA, \"C\" curve, complete all as specified and as directed. |
| 33 | S&F in repairs, MCB, SPN 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs, complete all as specified and as directed. |
| 34 | S&F MCB, SP,240 volts, breaking capacity 10 KA, rating, \"C\" curve 40 to 63 amps, complete all as specified and as directed. |
| 35 | S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. |
| 36 | S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs, complete all as specified and as directed. |
| 37 | S&F MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. |
| 38 | Excavation in trenches in soft/ loosesoil not exc 1.5 mtr wide and not exc 1.5 mtr deep in for lying of electric cable, pole foundation and stays etc and getting out, trimming the sides, forming bottom surfaces to required level, complete all as specified and as directed. |
| 39 | Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 250mm thick after cable are laid and tested, complete all as specified and as directed. |
| 40 | Removingexcavated material (Surplus soil) to a distance not exc 50m and depositing where directed at level not exc. 1.5m above the starting point, complete all as specified and as directed. |
| 41 | Supply and lay DWC Cable duct pipe of size 40 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories, complete all as specified and as directed. |
| 42 | Supply and lay DWC Cable duct pipe of size 75 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories, complete all as specified and as directed. |
| 43 | Supply and lay DWC Cable duct pipe of size 120 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories all as specified and directed. |
| 44 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 95 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 45 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 50 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 46 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 35 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 47 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 25 Sqmm, 4.0 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers, complete all as specified and as directed. |
| 48 | Dismantling and taking down Aluminium strip fixed on roof, floor wall and taking out old saddles and refixing aluminium strip on new porcelain saddles and connecting to earthing strip in original state, complete all as specified and as directed. |
| 49 | Supply & fix in replacement of single pointed air termination Alminium rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed. |
| 50 | Supply & fix in replacement of single pointed air termination Copper rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed. |
| 51 | Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm GI strip incl taking down u/s strip any type, complete all as specified and as directed. |
| 52 | Supply & fix in replacement of aluminium strip 25mmx 3mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip, complete all as specified and as directed. |
| 53 | M&L for straighting and alignment of existing aluminium strip connected as lightning condoctor in roof/ wall in any type of building, complete all as specified and as directed. |
| 54 | Supply & fix in replacement of HDPE/porceiline insulator15 BMD type Talongwith wooden gutkha with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etcto the wall / floor/pole or any indicated location etc, complete all as specified and as directed. |
| 55 | Supply and fixing in replacement of test point terminal block made of gun metal or phosphorusbronze size 75x75x25mm , drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw, complete with suitable polycaronate box with locking arrangement, complete all as specified and as directed. |
| 56 | M&L for Reconditioning of Lightning terminal by using of required insulators and necessary screwing work in roof and refixing of air terminatin as per existing, complete all as specified and as directed. |
| 57 | M&L for Reconditioning/ recharging of existing earthing including excavation of earth work upto 1.5 mtr from ground level and removing of soil and old materials near from earthplate as a distance of 300 mm and add salt and coal in a layer of 15 mm from bottem level upto earth plate, reassembling of funnel and water pipe, returning filling of soil and fifing of eath chamber, complete all as specified and as directed. |
| 58 | M&L in replacement of Earthing complete with galvanized steel earth plate electrodes 600x600x6 mmthick buried directly in ground earth (earth pit not less 2.25 m deep below groundlevel) with top edge of the plate not less then 1.5 mtr below normal ground level connectedtogalvanised iron wire 4mm dia by means of bolt nuts check nuts and washers of galvanized iron or steelall as specified & shownin electrical plate No.3 of MES SSR part-I 2009 connected to earth test pointas specified and testing on completion including provision of 40 mm dia lightgradepipeup to7.5 mtr length as protection & watering pipeshall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, complete all as specified and as directed. |
| 59 | Material and labour repair to self starter 12Volt of upto 40 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original stae after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed. Cat No SLF.001.00 |
| 60 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc andmaking good disturbed surfaces of walls, floors etc. and matching with existing surface, complete all as specified and as directed. |
| 61 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cable laid / fixed and including concealed in PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC modular boards and platefor mounting switches, sockets, fan regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch, complete all as specified and as directed.NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black).2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 62 | All as per item No. 61 here-in-before but for one 5 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 63 | All as per item No. 61 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size |
| 64 | All as per item No. 61 here-in-before buton independent board. |
| 65 | All as per item No. 61 here-in-before butfor one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 66 | All as per item No. 61 here-in-before butfor one light point controlled by 2 way switches. |
| 67 | All as per item No. 61 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth forone 15 Amp, 6 pin socket on independent board. |
| 68 | All as per item No. 61 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size |
| 69 | S&F modular switch one way, 6 Amp, one module, 230V, complete all as specified and as directed. |
| 70 | S&F modular switch one way, 16 Amp, one module, 230V, complete all as specified and as directed. |
| 71 | S&F modular switch, piano type, 6 Amp, single pole, two way, one module, 230V, complete all as specified and as directed. |
| 72 | S&F modular bell push, 6 Amp, one module, 230V, complete all as specified and as directed. |
| 73 | S&F modular socket, 6A, 3 pin combined 2 module, 230V, complete all as specified and as directed. |
| 74 | S&F modular socket, 6A/16A, 3 pin combined 2 module, 230V, complete all as specified and as directed. |
| 75 | S&F electric door bell, 230 V, multi music type, ISI marked, complete all as specified and as directed. |
| 76 | S&F lamp holder insulated, PVC / polycarbonate /bakelite body, complete all as specified and as directed. |
| 77 | S&F ceiling rose surface bakelite 65x50mm three terminal, complete all as specified and as directed. |
| 78 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cabledrawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boardsfor mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch, complete all as specified and as directed.NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black).2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 79 | All as per item No. 78 above but for one 3 pin socket outlet, 5 Amps on same board with other switches |
| 80 | All as per item No. 78 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size |
| 81 | All as per item No. 78 above but for one lightpoint controled by two, two way switch |
| 82 | All as per item No. 78 above but for one bell point controlled by one bell push |
| 83 | All as per item No. 78 above but for one 3 pin socket outlet, 5 Amps on independent board with cables, 1.5 sq. mm size. |
| 84 | All as per item No. 78 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth forone 15 Amp, 3 pin socket on independent board. |
| 85 | All as per item No. 78 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size |
| 86 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, complete all as specified and as directed. |
| 87 | S&F socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, complete all as specified and as directed. |
| 88 | S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, complete all as specified and as directed. |
| 89 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (3 pin ) 6/16 Amps, 230V, AC, complete all as specified and as directed. |
| 90 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish, complete all as specified and as directed. |
| 91 | S&Fbell,AC, 230 volts, single phase, complete all as specified and as directed. |
| 92 | S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way,protection class IP-43with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing, complete all as specified and as directed. |
| 93 | Supply and fixing LED round/square shape 6 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 94 | Supply and fixing LED round/square shape 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 95 | Supply and fixing LED round/square shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed. |
| 96 | S&F in repairs, 600 mm x 600 mm size, ultra slim,recess mounted LEDluminaire of capacity36watt, with driver, for soft glare free light, AC 230 voltcomplete with all acessories and connections, complete all as specified and as directed. |
| 97 | S & F LED Tube light fitting 20 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm, complete all as specified and as directed. |
| 98 | S & F LED Tube light fitting 10 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm, complete all as specified and as directed. |
| 99 | Surface mounted, decorative round plastic bulk head LED luminaire comprising of high brightness LED\"s, IP54 protection, 10 watt, 6000K complete fitting with LED lamp, driver and all other fixing accessories including electric connection connecting with using flexible copper wire twin core upto ceilling rose/connector including taking down old unserviceable light fitting any type, complete all as specified and as directed. Charge. |
| 100 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp all fittings and accessories, complete all as specified and as directed. |
| 101 | S&F in repairs, security light fitting of building with single piece new generation energy savng and environmental friendly, long life, LED 30W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07including one bracket made of light gradeGI Pipe 25 mm dia, 1.5 mtr long, fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connect to nearest electric supply by two core 1.5 sqmm aluminium cable, complete all as specified and as directed.Make : Havells Cat No LHEXAY7PN6K030 or equivalent model of make Philips / Crompton Wipro/Surya |
| 102 | S&F in repairs, LED edge light panel drivers of capacity 18 W to 36 W with universal connector for easy installations, complete all as specified and as directed. |
| 103 | S&F in repairs, LED edge light panel drivers/post top lamp of capacity 42 W with universal connector for easy installations, complete all as specified and as directed. |
| 104 | S&F in repairs PVC casing caping 32 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size, fixed in replacement, complete all as specified and as directed. |
| 105 | S&F in repairs PVC casing caping 100 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size, fixed in replacement, complete all as specified and as directed. |
| 106 | S&F in repairs, PVC rectangular box of 100 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 107 | S&F in repairs, PVC rectangular box of 175 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 108 | S&F in repairs, PVC rectangular box of 200 mm x 150mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 109 | S&F in repairs, PVC rectangular box of 250 mm x 200mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed. |
| 110 | S&F in repairs, PVC rectangular box of 350 mm x 300mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc, complete all as specified and as directed.Note Cutting of board for mounting switch,sockets, fan regulators etc. shall be as per site requirement. |
| 111 | S&F in repairs, modular cover plate frame, 2 module, complete all as specified and as directed. |
| 112 | S&F in repairs, modular cover plate frame, 4 module, complete all as specified and as directed. |
| 113 | S&F in repairs,modular cover plate frame, 6 module, complete all as specified and as directed. |
| 114 | S&F in repairs, modular cover plate frame, 8 module, complete all as specified and as directed.Note:(i) Item shall be executed to attend day to day complaints.(ii) Burnt/damaged fitting only shall be replaced.(iii) Wiring is not included in the item. |
| 115 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size4 sqmm, two core, complete all as specified and as directed. |
| 116 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size6 sqmm, two core, complete all as specified and as directed. |
| 117 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size10 sqmm, two core, complete all as specified and as directed. |
| 118 | S&F repairs 5/6 Amp plug top 230 volts, single pole, white/ivory finish, complete all as specified and as directed. |
| 119 | S&F repairs 15/16 Amp plug top 230 volts, single pole, white/ivory finish, complete all as specified and as directed. |
| 120 | S&F in repairs, sheet metal enclosureswith plug socket, single pole and neutral with two pin and earth plug with one MCB of 20 Amps (SP), complete all as specified and as directed. |
| 121 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 122 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm diaPVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 123 | M & L for sub main wiring with 2 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm diaPVC conduit conforming to IS-9537 / suitable size casing caping(ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 124 | M & L for sub main wiring with 4 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping(ISI marked)with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit, complete all as specified and as directed. |
| 125 | Taking down of exhaust fan upto 450/300mm sweep, opening, replacement of unserviceable accessories, servicing, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing / hanging in position from ceiling rose to fan, complete all as specified and as directed.(Note : gun metal bush, bearing will be measured and paid under relavant item here-in-after). |
| 126 | Supply only gun metal bush of sizes suitable for exhaust fan upto 450 mm sweep, complete all as specified and as directed. |
| 127 | Supply only ball bearing No 6203 suitable for fan of existing make type & sweep, complete all as specified and as directed.Make:- NBC/SKF/TATA |
| 128 | Checking of exhaust fan(of any sweep) by replacing unserviceable capacitor/ tightening the loose connections if any including testing, complete all as specified and as directed.(Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after) |
| 129 | M & L for painting of exhaust fan carefully with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc, complete all as specified and as directed. |
| 130 | M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300mm dia, complete all as specified and as directed. |
| 131 | S & F INVETER LED Tube light fitting 20 Watt with square profile and polycarbonate channel. lITHIUM Ion battery with charging time 8 to 10 hrs and back up time upto 4 hrs LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with, complete all as specified and as directed. |
| 132 | S&F in repairs, LED9W Bulb, 230 Volts AC supply, complete all as specified and as directed. |
| 133 | S&F in repairs, LED9WInverter Bulb, 230 Volts AC supply, complete all as specified and as directed. |
| 134 | Note : In case of doubling / duplicancy of BOQ items, the lowest quoted rate shall be applicable for payment |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail