| Sl. No. | Item Description |
| 1 | NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE(a)The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after.(b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor.(c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher.(d) The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE.(e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement.(f) The quoted rates shall be inclusive of cost for necessary scaffolding for working under AoR of GE (U-II). |
| 2 | Supply & laying MS ERW pipe of followingdia heavy grade for inserting in position, making leak proof joints including fittings and testing the pipe line for leakage, taking down unserviceable including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge:- |
| 3 | 150 mm dia |
| 4 | 100 mm dia |
| 5 | 80 mm dia |
| 6 | S & F in repair GM fire hydrant landing valve type A (single head outlet) of 63 mm dia with new hydrant ISI mark, complete all as specified and directed by Engineer-in-Charge. |
| 7 | S & F in repair GMfire hydrant landing valve type B (Double head outlet) of 63 mm dia with new hydrant ISI mark, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material and labour forPCC (1:3:6) type C2 using 40 mm graded stone aggregate as a base foundation for the pipe lines including one coat of white wash and necessary formwork, complete all as specified and directed by Engineer-in-Charge.Note:- The quoted rates shall be inclusive of removing the damaged PCC base foundation & levelling the surface as per direction of Engr-in-Charge |
| 9 | Taking down & refixing the old fire hydrant valves of size 63/80mm dia from hydrant post and removing the corrosion, changing the damaged pins from pivot end, softening the shaft of iron wheel and applying the greese for lubrication of fire hydrant valves, complete all as specified and directed by Engineer-in-Charge.Note:- The quoted rates shall be inclusive of Nut & Bolts, rubber gaskets and other connected items. |
| 10 | Repair/ maintenance of fire hose box by changing of damaged doors along with locking arrangements, front glass of existing size, PCC foundation and necessary rubber gaskets for doors, complete all as specified and directed by Engineer-in-Charge.Note:- The quoted rates shall be inclusive of one coat red-oxide paint, paint red and inside clean white paint and numbering of box as directed by Engr-in-Charge. |
| 11 | S & F in repair 15 mtrs long percolating canvas hose of 63mm dia gun metal male and female coupling with copper winding conforming to IS 903, complete all as specified and directed by Engineer-in-Charge. |
| 12 | S & F in repair hose reel drum 30 mtrs length, complete all as specified and as directed. |
| 13 | S & F in repair fire hose box made of 18 gauge MS sheet 1200mm x 900mm x 600mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white insideand numbering of box with white paint on a circular black background paint of size, complete all as specified and as directed. |
| 14 | S & F in repair fire hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside and numbering of box with white paint on a circular black background paint of size, complete all as specified and as directed. |
| 15 | Supply and fix 63 mm SS branch pipe and nozzle confirming to IS:903 including dismantling old unserviceable, complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for construction of brick masonary andvalve chamber of following size internal dimensions with angle iron frame and MS sheet cover3mm thick duly painted 2 coats of red oxide zinc chromate primer including lifting handle, locking arrangement, excavation and earth work, plastering, complete all as specified and directed by Engineer-in-Charge:- |
| 17 | 900 mm x 900 mm x 900 mm |
| 18 | 1200 mm x 1200 mm x 1200 mm |
| 19 | Labour for pressure testing of existing 150 mm DI/MS fire main system, identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut, bolts etc of flanged joints/ defective flanges etc for making the system leak proof, complete all as specified and directed by Engineer-in-Charge.Note:- (a) The rate quoted shall be deemed to be inclusive of T&P such as air compressor for pressure testing etc (b) Earthwork, DI/MS pipe & specials required for rectiifcation shall be measured and paid separately under relevant items BOQ. |
| 20 | M & L for Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint including numbering of stand post and hose box at places as per requirements with white paint on black paint circular background of size, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Surface dressing in soft/loose soil not exeeding 15 cm deep, across the pipe lines and including site clearence, cutting and cleaning of branches / bushes / plants / grass obstructing the pipe lines /valves / chambers / sumps / OHTs on either sides and water supply Installation area including disposal of materials up to a distance not exceeding 50 m, complete all as specified and directed by Engr-in-Charge. |
| 22 | S & F in repair single hydrant stand post made of MS pipe of size80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding to suit single fire hydrant valve and testing, complete all as specified and directed by Engineer - in - Charge. |
| 23 | Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested, complete all as specified and directed. |
| 25 | Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc.1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Repairing / Servicing and reassembling the Jockey pump set and motor of capacity 10 HP to 20 HP as per the original assembly after repairs / replacing the worn out unserviceable parts,including cleaning replacing the bearings for both pumps & motors including packing bolts, nuts washers and MS clamps etc and applying one coat of approved enamel painton exposed steel surface, making the pump and motor fully serviceable including machine work etc and testing the both after refixing and commissioning for satisfactory operation on its full load, complete all as specified and directed by Engineer - in - Charge |
| 27 | M&L for repair & overhauling of squirrel cage induction electrical motor of following capacities, 3 phase, 415 volts including disconnecting all electrical connections, decoupling from pump, taking down the motor from foundation, cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump, checking alignmentconnecting all electrical connections, checking the vibrations, RPM, DOR, painting with one coat of synthetic enamel paint after preparing the surfaces and testing on full load, complete all as specified and directed by Engineer - in - Charge :- |
| 28 | 100 HP induction motor |
| 29 | 40 HP induction motor |
| 30 | M&L for repair & overhauling of centrifugal pump set of following capacities and of any make, dismantling and taking down pump after disconnecting water supply connections, decoupling from motor removing out impeller, cleaning, descaling, greasing to bearings including replacement of unserviceable parts such as bearings DE & NDE, pump shaft sleeves, coupling pully, pump shaft etc.Assembly in the pump with new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling boltsand coupling with motor checking for vibration & alignment connectingdelivery and suction pipe, painting with one coat of synthetic enamel paints testing the pump set, complete all as specified and directed by Engineer - in - Charge :-Notes :- (i) Cost of smallU/S parts such as new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts shall deemed to be included in quoted rates (ii) Major unserviceable spares shall be measured and paid separately as supply only. |
| 31 | 100 HP to 75 HP |
| 32 | 40 HP to 65 HP |
| 33 | Supply only the following items, complete all as specified and directed by Engineer - in - Charge :- |
| 34 | Bearings DE & NDE for 100 HP to 75 HP |
| 35 | BearingDE and NDE for pump coupled with 100 HP to 75 HP motor |
| 36 | Bearing DE and NDE for 40 HP to 65 HP motor |
| 37 | Bearing DE and NDE for pump coupled with 40 HP to 65 HP motor. |
| 38 | Pump shaftsleeves for 100 HP to 75 HP pump set. |
| 39 | Pump shaft sleeved for 40 HP to 65 HP pump set |
| 40 | Pump shaft high carbon steel with check nut for 100 HP to 75 HP pump set |
| 41 | Pump shaft high carbon steel with check nut for 40 HP to 65 HP pump set |
| 42 | S&F gland packing or required size of gland of superior quality to centrifugal / monoblock pumps of following capacities, complete all as specified and directed :- |
| 43 | 100 HP |
| 44 | 40 HP |
| 45 | M&L for replacement of pumpset coupling pully with rubber band,nuts and bolts for the following capacity, complete all as specified and directed :- |
| 46 | 100 HP |
| 47 | 40 HP |
| 48 | Labour only for attending break down of 300/250/200 mm dia CI/DI/MS pipeline bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering complete all as specified and directed by Engr-in-Charge.Note 1 :- The quoted rate shall deemed to be inclusive of the following:-(i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary Earth Work, labour/trade men for attending break down. (iii)Labour element required for fixing CI/DI/MS pipes, specials, fittings etc.Note 2 :- M & L for Lead joints, DI/ MS pipes, specials, fittings shall be measured and paid seperately under relevant items. |
| 49 | All as per Srl item No 27.00 above but of 150/100/80 mm dia pipeline |
| 50 | Supply onlyDuctile Iron pipe of 150mm dia conforming to IS-8329:2000, with socket & spigot ends, Class \"K9\" including flexible push on joint in any length laid in trenches, complete all as specified and directed. |
| 51 | M & L for Burning out lead joint for 150mm bore in position including removing old lead to store, complete all as specified and directed. |
| 52 | Material and labour for run lead joint for spigot and socketpipes (CI/DI) of 150mm bore and fittings, complete all as specified and directed by Engr-in-Charge. |
| 53 | Supply only DI Specials (any type radius and angle) tapers any type straight increasing decreasing or double socket and \"\"Y junction double branch, Collar,cross (allsockets or socket and spigot) caps and plugs upto 300 mm bore, complete all as specified and directed. |
| 54 | Servicing/maintenance of dial type water level indicator by replacing wornout central movement plate, counter weight, centre diving wheels etc., and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and as directed. |
| 55 | M&L for painting of pumpsets of following capacity with a coat of approved synthetic enamel paint including inlet & out let pipe lines complete including preparation of old painted surface and writting MES number, complete all as specified and directed by Engineer-in-Charge:- |
| 56 | 90 HP to 100 HP |
| 57 | 40 HP to 75 HP |
| 58 | 20 HP to 40 HP |
| 59 | 7.5 HP to 15 HP |
| 60 | 2 HP to 7 HP |
| 61 | M & L for arresting water leakage fromsluice valve of following dia, byrefacing, regrinding of sluice Valve, Repacking stuffing box of sluice valve spindle including taking apart and reassembling the same including replacing oldcheck nuts with new onemade out of MS/CI material, with and including replacing perished gland packing, rubber gasket, bolts and nuts, complete all as specified and directed by Engineer-in-Charge:- |
| 62 | 80 mm bore |
| 63 | 100 mm bore |
| 64 | 150 mm bore |
| 65 | Supply and replace CI foot valve ball type with necessary rubber gasket, bolts, nuts and washers for following size, complete all as specified and directed by Engineer-in-Charge:- |
| 66 | 80 mm bore |
| 67 | 150 mm dia. |
| 68 | Material and labour for taking down defective foot valves of following sizes from UG Sump, scraping the corrodedfootvalves and painting with one coat of red oxide along with black enamel paint, replacingrubber gaskets, bottom rubber with spring complete with replacement of necessary bolts, nuts, washers, complete all as specified and directed by Engineer-in-Charge:- |
| 69 | 150/200 mm dia |
| 70 | 80/100 mm dia |
| 71 | Supply and fixwater pressure gauge standard dia 2\" dia dial , Range 0-40 Kgs at the delivery side of pump sets complete tubing, fitted with stop cock etc, complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply only Calcium Hypochlorite, 65 %-70 % in granular form for water treatment, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fix in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed by Engineer-in-Charge. |
| 74 | S & F in repair Solar Street Light luminaire wattage 30 W, >125 lumen/watt including suitable tubular pole of 5 m height mounted with inbuilt battery (LiFEP04) 12.8 V, 36Ah, having 70 W Mono Crystalline SPV panel auto on / off of lights while dusk to dawn, motion sensor and 3 stage dimming of LED, complete all as specified and directed by Engineer in charge |
| 75 | M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth notless than2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earthstrip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth strip protected by galvanised iron pipe 40 mm bore, medium grade and connected to main switch board or main control board / DG Set as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 3 of MES Schedule Part- I and testing on completion, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Material and Labour for servicing of Fire pump Diesel Engine of capacity 97 BHP of any make / model by carrying out the following maintenace maintenance as per manufacturers instructions including cleaning the engine, pump, completely by blowering and with cotton waste and testing on completion, complete all as specified and directed by Engineer-in-Charge:-(a) Draining out engine oil from the sump by removing drain plug, cleaningthe sump thoroughly and refilling the sump with new engine oil to required level, complete all as specified and directed by Engineer-in-Charge.Note:- Engine Oil shall be measured and paid separately as \"Supply Only\".(b) Draining out of diesel from tank and storing in cleaned containers, cleaningthe tank thoroughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered, complete all as specified and directed by Engineer-in-Charge.(c) Supply and replace complete set of engine oil filters, fuel filters, Bypass filter, air cleaner element and water separator, complete all as specified and directed by Engineer-in-Charge.(d) Draining out complete coolant water mixture from the radiator and re-filling the radiator with new coolant and water mixture with proportionate ratio, complete all as specified and directed by Engineer-in-Charge.Note:- Coolant shall be measured and paid separately as \"Supply Only\".(e) Check and top up the electrolyte/distilled water in starting batteries to maintain the required specific gravity. Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors.(f) Checking and Tightening all the fasteners of complete engine to the required torque, if required. |
| 77 | Supply and replace complete set of fuel pipes & leak off pipe with clamps suitable for existing make & model of Fire pump diesel engine of capacity 60 BHP to 112 BHP, complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply and replace \"V\" belt suitable for existing make & model of Fire pump diesel engine of capacity 65 HP to 112 HP, complete all as specified and directed by Engineer-in-Charge. |
| 79 | Supply and replace complete set of hoses with clamps suitable for existing make & model of Fire pump diesel engine of capacity 65 BHP to 112 BHP, complete all as specified and directed by Engineer-in-Charge. |
| 80 | Material & Labour for rewiring of engine safety control system from control panel to engine control gadgets like HWT, LLOP, shut down valve, dynamo & self-starter etc with suitable gauge and grade of wires for Fire pump diesel engine of capacity 65 BHP to 112 BHP including taking down unserviceable engine wiring, complete all as specified and directed by Engineer-in-Charge. |
| 81 | Dismantling the defective self starter assembly 12V/24V carefully from the fire pump diesel engine and carryout repair and servicing by cleaning all accessories with suitable cleaning agent and supply and replace commutator, carbon brush set, carbon brush holder, king pin holder, armature choke nut, body screens, clutch plate assembly and solenoid etc, re-assembling and re-fixing the same and testing on completion for Fire pump diesel engine of capacity65 BHP to 112 BHP, complete all as specified and directed by Engineer-in-Charge. |
| 82 | Material and labour for preparation of old painted surfaces of fire fighting pump sets of capacity 65 to 97 BHP and painting to electric pump and motor / fire diesel engine set and base frame with two coats of synthetic enamel spray paint of approved colour as per standard MES colour coding, complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply and replace Cast Iron sluice valve of size 200mm dia bore, having pressure rating PN 1.6, double flanged,non-rising stainless steel spindle with iron wheel conforming to IS:14846-2000with jointing material i.e. new rubber gasket, GI nuts, bolts & washers etc of suitable size including taking down existing old unserviceable sluice valve, complete all as specified and directed by Engineer-in-Charge. |
| 84 | All as per item No. 50.00 here-in-before but of size 150mm dia bore. |
| 85 | All as per item No. 50.00 here-in-before but of size 100mm dia bore. |
| 86 | All as per item No.50.00 here-in-before but of size 80mm dia bore. |
| 87 | Supply and replace Cast Iron Non Return Valve (NRV) 150 mm NB with flanged ends swing type / ball type as per site requirement, including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable NRV of any description, complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply and replace Cast Iron foot valve of size 200 mm NB, flanged end ball type/ swing type including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable foot valve of any description, complete all as specified and directed by Engineer-in-Charge. |
| 89 | All as per item No.55.00 here-in-before but of size 150mm NB |
| 90 | Supply and fix in replacement of CI Butterfly valve of size 150mm nominal bore as per IS 13095, PN 16, wafer type without lugs, suitable for clamping between flanges as per ANSI B 16.1 CI-125, including flanges, fittings, gasket, nuts, bolts, washers etc. including taking up / down of existing unserviceable butterfly valve of any description, complete all as specified and directed. |
| 91 | All as per item No. 57.00 here-in-before but of size 100mm NB |
| 92 | Supply and fix in replacement ofGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 50mm bore dia and fixedincluding taking up / down of existing unserviceable gate valve of any description, complete all as specified and directed by Engineer-in-Charge |
| 93 | All as per item No. 59.00 here-in-before but of size 40mm NB |
| 94 | All as per item No. 59.00 here-in-before but of size 25mm NB |
| 95 | All as per item No. 59.00 here-in-before but of size 20mm NB |
| 96 | Supply and connecting in replacement of 2 core, 2.5 sqmm power cable with copper conductor, PVC insulated, cores laid up, PVC inner sheathed, armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS:1554(Part-1)laid / fixed in cable duct / fixed to walls / steel posts etc including taking out of existing unserviceable control cable of any description, complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supply and fix MCCB 400A, 4 Pole, 50 KA, thermal magnetic release, adjustable overload and short circuit, Ics = 100% Icu, AC 3 phase, 415 Volts, 50 Hz, with and including spreader terminals including connecting up incoming and outgoing cables with suitable stainless steel cable glands and aluminium cable lugs including taking down existing unserviceable MCCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply and fix MCCB 200A, 3 Pole, 36 KA, thermal magnetic release, adjustable overload and short circuit, Ics = 100% Icu, AC 3 phase, 415 Volts, 50 Hz, with and including spreader terminals including connecting up incoming and outgoing cables with suitable stainless steel cable glands and aluminium cable lugs including taking down existing unserviceable MCCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply and fix MCCB 100A, 3 Pole, 25 KA, thermal magnetic release, adjustable overload and short circuit, Ics = 100% Icu, AC 3 phase, 415 Volts, 50 Hz, with and including spreader terminals including connecting up incoming and outgoing cables with suitable stainless steel cable glands and aluminium cable lugs including taking down existing unserviceable MCCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply and fix MCB, 63 A, 10 KA, 4 pole, \"C\" Curve, 415 V, 50 Hz including taking down unserviceable MCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply and fix MCB, 32 A, 10 KA, 2 pole, \"C\" Curve, 230 V, 50 Hz including taking down unserviceable MCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply and fix MCB, 6-32 A, 10 KA, single pole, \"C\" Curve, 230 V, 50 Hz including taking down unserviceable MCB of any description, complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and fixing in replacement of power contactor of following sizes 3 pole, coil voltage 230/415 Volts, 50 Hz with 2NO + 2NC, complete all as specified and directed:- |
| 104 | 100 Amps |
| 105 | 125 Amps |
| 106 | Supply and fixing in replacement of Thermal Overload Relay, direct mounting for the relay setting range 45-75 Amps suitable for AC, 3 phase, 415 Volts motor, complete all as specified and as directed. |
| 107 | Supply and fixing in replacement ofSingle phase preventor for single phasing, phase sequence and phase unbalance monitoring with auto reset for AC, 3 Phase, 415 V Induction Motor, complete all as specified and directed. |
| 108 | Supply and fixing in replacement of Electronic Timer, 3 to 30 Seconds, 240 / 360 / 415V, 50Hz, complete all as specified and as directed. |
| 109 | Supply and fixing in replacement of 3 phase digital Voltmeter / Ammeter, Cl 0.5 flush mounting suitable for fixing in existing panel, complete all as specified and directed. |
| 110 | Supply and fixing in replacement of LED indication lamp Red/Yellow/Blue/Green colour, complete all as specified and directed. |
| 111 | Supply and fixing in replacement of Push Button Switch for ON/OFF operations Red / Green colour, complete all as specified and directed. |
| 112 | Supply and fixing in replacement of Auto-Manual Changeover selector switch suitable for panel mounting, complete all as specified and directed. |
| 113 | Labour only for thorough checking of existing automatic fire fighting pump set control system for serviceability of each and every component such as Pressure switches, sensors, gauges, PLC system, electromagnetic power relay, contactors, OLR, Timer, preventor, control wiring, panel accessories etc complete and identifying and replacing the defective components for satisfactory functioning of automatic fire fighting control panel based on pressure sensing in the fire mains by deploying qualified and experienced technician in the relevant field, complete all as specified and directed by Engineer-in-Charge. Note: Spare parts required shall be measured and paid separately under relevant items of BOQ. However, cost of minor spare parts costing up to Rs. 500/- shall deemed to be included in the quoted rate. |
| 114 | Material and labour for Supply, installation and testing of LED flex Glow Sign Board for frontlit office / installation boards prints stretched on a metal frame, where the sun or the ambient light lends visibility to the board complete comprising of the following components with below given detailed specifications including taking down of existing unserviceable office / installation sign board of any description, complete all as specified and directed:-(i) Metal Frame / Box: The base structure of board should be made of a metal frame in the form of a box of 6 – 8 inches deep and the width and the height and shape of the frame are as per site requirement and as directed by Engineer-in-Charge by using 0.5 – 0.75 inch thick, metal pipes to fabricate the box.(ii) Tin Sheet / Patra: The above box should be wrapped by a tin sheet or ‘patra’ on the back and the sides in a standard black or white colour as directed by Engineer-in-Charge.(iii) LED tubes as a Source of Light: LED tubes as the source of light for GSB, fitted inside the box. Qty of LED tubes shall be as per the manufacturers recommendations based on the size of GSB decided by Engineer-in-Charge. Make of LED tubes : Havells / Bajaj / Crompton / Wipro / Philips(iv) Brackets to Hold the Board in Place: Completed board shall be fitted on wall / metal structure with suitable shaped brackets, nuts, bolts and washers etc and GI wires as per site requirement and as directed by Engineer-in-Charge. |
| 115 | (Item No 79.00 Contd---)(v) Printed Star Flex: The office / installation board design / art work shall be as per sample given by GE / Engineer-in-Charge printed on a specialised media known as Backlit Star Flex 350 GSM with UV ink prints / Eco Solvent ink prints layered in a double strike. This print should has the following characteristics:- Flex is a printable roll of plastic with a cloth like weave on the back. The front surface should specially coated to receive inkjet inks. Print should be waterproof, scratch-resistant and fade-resistant. The denier or the weave on the back lends strength to the print. The weave and printable top layer of backlit flex should be translucent. It should allow light to pass through and when this happens, the print on top gets a very beautiful glow. ‘Star’ is a premium brand of flex. Prints on Star flex have a very high resolution extremely vibrant colours.Note:-(a) The size, dimensions and shape of varying dimensions shall be as per site requirement and as specified and directed by GE / Engineer-in-Charge. (b) The measurement of the completed board shall be measured in square feet on the front face only and hence the quoted rate shall deemed to be included for the depth of the board i.e. 6 to 8 inches. (c) The quoted rate shall be inclusive of cost of transportation to site and installation at any height / in any position and the fixing brackets and accessories and dismantling of existing unserviceable sign board of any description complete all as specified and directed by Engineer-in-Charge. |
| 116 | Material and labour forsun boards or foam boards for offices / installations made of 3mm-thick foam with a smooth matte printing surface in customisable design templates in any size and shape and printing the details as provided by Engineer-in-Charge as per his directions. The printing shall be done using digital technology that should give the sun board a sharp and professional look. The Vinyl sun boards should have a stiff property with good protection against direct sunlight to avoid colour fading & cracking, resulting in good shelf life, complete all as specified and directed by Engineer-in-Charge. Note: (a) The quoted rate shall deemed to be inclusive of transportation to site and fixing with suitable fixing accessories complete all as specified and directed by Engineer-in-Charge. (b) The measurement of the completed board shall be measured in square feet.(c) Quoted rate shall be inclusive of custom printing charges.(d) Quoted rate shall deemed to be inclusive of dismantling and taking down of existing unserviceable sign boards of any description. |
| 117 | Material and labour for highly durable custom-cut aluminium signs made of aluminium sheet of thickness of 1.2mm custom Printed With Full-Colour, 600 DPI, UV Printing Technique to produce high-resolution and easy-to-read graphics on custom reflective aluminium signs. The high-end printing should provide signs with the best colour match, longer print life, and clarity. It should be fade or crack proof even after years of use. Printing shall be on single or double-sided printing option depending upon site requirement. The customisable letters and figures shall printed on vinyl and paste it on the aluminium sheet to give signs a premium look and suitable for indoor / outdoor applications, complete all as specified and directed by Engineer-in-Charge. Note:(a) The quoted rate shall deemed to be inclusive of transportation to site and fixing with suitable fixing accessories complete all as specified and directed by Engineer-in-Charge.(b) The measurement of the completed board shall be measured in square feet. (c) Quoted rate shall be inclusive of custom printing charges. (d) Quoted rate shall deemed to be inclusive of dismantling and taking down of existing unserviceable sign boards of any description. |
| 118 | Supply only engine oil of grade 15W-40 for various diesel engines, complete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply only of premix coolant water mixture (50:50 ratio) suitable for diesel engines sets, complete all as specified and directed by Engineer-in-Charge. |
| 120 | Material and labour for Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment inclusive of one primer coat, one under coat and one finishing coat of paint of approved colour including cutting and removing old corroded MS sheet / plate of any description, complete all as specified and directed by Engineer-in-Charge. |
| 121 | M&L Washing rubbing down and stopping of distempered surfaces any type of wall upto 4th floor incl preperation and then applying one coat of oil bound distemper on old plastered surface by Auto roller of any tint, complete all as specified and directed by Engineer-in-Charge. |
| 122 | M&L Preperation of old plastered surfaces ofwall upto 4th floor and apply one coat of white wash, complete all as specified and directed by Engineer-in-Charge. |
| 123 | M&L Preperation old painted surfaces of steel upto 4th floor and applying one coat of synthetic enamel paint ony description not other described over 10cm width or girth,complete all as specified and as per specified by Engineer -in-Charge. |
| 124 | M&L for preparition of wall upto 4th floor by Vaccum based sanding machineremoval of nails etc and then apply one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm by using auto roller, complete all as specified and directed by Engineer -in-Charge. |
| 125 | Taking down cement plaster on brick wall stone wall etc including raking outjoints, hacking for key securing down with water etc, complete all as specified and directed by Engineer-in-Charge. |
| 126 | M&L, rendering 15 mm thickin cement mortar 1:4 on other than fair face of brick or surface finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 127 | M&L, rendering 10 mm thickin cement mortar 1:6 on other than fair face of brick or surface finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 128 | M&L for applyingtwo coats 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 Lit/10 Sqm over newly plasteredby auto roller upto 4th floor surfaces incl preparation of surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 129 | M&L for preparation of newly plastered surfacesof wall upto 4th floor by Vaccum based sanding machine applying 3mm wall care putty (Multipurpose mixer shall be used for uniform and poper mixing of putty ) and applyingtwo coats ofemulsion distemper white or colouredover a coat of alkaline resistant primer by auto roller, complete all as specified and directed |
| 130 | Supply and fixing in repair 15mm bore fancy type chromium plated bib tap cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule etc, complete all as specified and as directed. |
| 131 | Supply and fixing in repair pillar taps, fancy type 15mm dia bore, chromium plated, screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed. |
| 132 | Supply and fixing in repairs 10 litre capacity PVC low level flushing cisternwith all accessories complete fixed with WC including syphonic pipe, PVC flushing pipe of size 32mm dia, complete all as specified and directed. |
| 133 | Supply and fixing in repairs 15mm dia bore stop cock/angle cock, cast fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe on for unions and fixed, complete all as specified and as directed. |
| 134 | Supply and fixing in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden /plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 135 | S & Fin repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size(flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand, complete all as specified and directed by Engineer-in-Charge. |
| 136 | Supply and fixing in repair vitreous China wash down water closet pan (pedestal pattern) white, incl. P or S Trapof 100mm bore dia, connection to drain and flushing pipe including seat cover for pedestal pan, complete all as specified and as directed. |
| 137 | Supply and fixingin repairs PVC connection 15mm dia and 600mm long with PTMT nuts, complete all as specified and as directed. |
| 138 | Supply and fixing in repairs 5.50mm thick of size600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 139 | Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections, complete all as specified and as directed. |
| 140 | Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking up or down of 20 mm dia steel tubing, complete all as specified and directed by Engineer-in-Charge. |
| 141 | Supply and fixing in repair 100mm mild steel butt hinges medium weight including screws, complete all as specified and as directed. |
| 142 | Hacking out old broken glass of any thickness/ size of any description from wooden/aluminium frame fixed with clips and putty, and Supply and fix 4mm thick ordinary Sheet glass fixed with clips and putty completed in squares in not exc 0.5 sq.m in each pane, complete all as specified and as directed. |
| 143 | Hacking out old broken glass of any thickness/ size of any description from wooden/aluminium frame fixed with clips and putty, and Supply and fix 4mm thick frosted glass fixed with clips and putty completed in squares in not exc 0.5 sq.m in each pane complete all as specified and as directed. |
| 144 | Supply and fix in repairsStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 145 | Supply and Fix in repair floor door stopper of aluminium alloy,anodised with hard drawn steel spring of length 150mm, complete all as specified and as directed. |
| 146 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not hacking) removing serviceable tiles to stores and rubbish off premises, complete all as specified and as directed. |
| 147 | Material and labour Dark shade/ Double charged/Ultra charged Virified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding Screed bed or bedding layer of mortar 15 mm thick in CM 1:6for laying floor finishes, complete all as specified and as directed. |
| 148 | All as per item No.111.00 above but in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding backing coat of 10 mm thick in CM 1:4on brick walls for skirting/DADO. |
| 149 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) exe 1.5Sqm n exe 4.0 Sqm each and removing to stores etc complete all as specified and as directed. |
| 150 | Supply and fixing 2nd class hardwood Plain, solid, straight Chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed. |
| 151 | S&F 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side face is covered with decorative face veneer with lipping / frame and fitted to chowkhat, complete all as specified and directed . |
| 152 | Supply and Fix aluminium anodised barrel tower bolts 200mm sizeof extruded section complete all as specified and as directed. |
| 153 | Supply and fix aluminium handles Cast type anodized 150mm sizeetc complete all as specified and as directed. |
| 154 | Supply and fix Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed 250 mm long complete all as specified and as directed. |
| 155 | Material and labour preparation of new wooden surfaces of any description over 10cm in width of girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 156 | Material and labour in repair 75mm dia PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 157 | Material and labour in repair 110mm dia PVC(SWR) gully trap setting and hoisting with solvent cement, complete all as specified and directed. |
| 158 | Supply and fixing in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. |
| 159 | S&F in repairs 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 160 | S&F in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 161 | S&Fin repairs 110mm dia PVC (SWR) bends any radius, complete all as specified and directed. |
| 162 | S&Fin repairs 75mm dia PVC (SWR) bends any radius, complete all as specified and directed. |
| 163 | S&Fin repairs 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 164 | S&Fin repairs 75 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 165 | Supply and Fixfloor door stopper of aluminium alloy,anodised with hard drawn steel spring of length 150mm complete all as specified and as directed. |
| 166 | Dismantling of corrugated or semi corrugated Asbestos cement sheets / Galvalume sheets in roof covering complete all as specified and directed. |
| 167 | M&L for 0.50 mm thick pre-painted corrugated/’Z’ profile galvalume roofing sheets as in roofing (in any location and any type) having high strength steel with minimum 550 Mpa strength hot dip coated with aluminium zinc alloy (55% aluminium and 45% zinc) pre-painted with primer coat of 5 micron and coated with Silicon modified polyester coating of 20 micron and alkalyed coating of 10 micron on reverse side. End rib, side over lap and over lap of sheets shall be designed for anti capillary activities to avoid any seepage of water through lateral overlap as per manufacturer’s instructions, including fixing with self drilling and self tapping screws 0.5mm dia full threaded, all Kautex coated and fitted with EPDM washers in stainless steel. The screws shall be coated with anti-corrosive substance to ensure longer life and shall be fixed using drill guns for lead proof installation complete all as specified and as directed. |
| 168 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 169 | S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position, complete all as specified and directed. |
| 170 | S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position, complete all as specified and directed. |
| 171 | S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 5000 Ltrs capacity hoisted and fixed in position, complete all as specified and directed. |
| 172 | S&F20 mm diaballvalves, PTMT high pressure of epoxy coated Aluminium rod and high density plastic ball (200 gms), screwed for iron pipes or brasas ferrule and fixed, complete all as specified and directed. |
| 173 | Supply and fix in repairs Mortice lock vertical type, size 100mm of brass 4 Levers complete all as specified and as directed. |
| 174 | Demolition ofPlain cement Concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 175 | Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes for 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 176 | Demolition of brick work built in cement mortar or lime mortar including all quionts, arches, pillers etc but excluding ashlat facing, dressed stone work amd pre cast concrete articles, complete all as specified and directed. |
| 177 | M&L for brick work with Flyash bricks straight or curved on plan exc 6m mean radius built in CM (1:4), complete all as specified and directed. |
| 178 | M & L for Rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:4 mixed with water proofing compound finished fair and even (without using extra cement) complete as specified and directed.Note:- Water proofing compound shall be measured and paid separately. |
| 179 | Supply only integral water proofing compound complete all as specified and directed. |
| 180 | M & L for Plain cement concrete 1:4:8 type D2 (using 40mm graded granite stone aggregate)in foundation, filling and mass concrete complete all as specified and directed. |
| 181 | M&L Plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in benching to manholes, coping etc.. including necessary formworks, complete all as specified and directed. |
| 182 | M&L for PCC (1:2:4), type B1 in surface channel & drains incl necessary form work complete all as specified & directed. |
| 183 | M&L salt glazed stoneware drain pipe of 150mm internal dia of grade \"A\" laid in trenches and jointing in cement mortar, complete all as specified and directed. |
| 184 | Demolition of cement concrete reinforced cover slabs of man holes etc n.exc 15 cm thick, complete all as specified and directed. |
| 185 | Precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole/ gully trap cover slab set in cement mortar 1:4 including necessary form work, complete all as specified and directed. |
| 186 | S & F TMT bars 10mm and over cut tro length,bend to shape required incl cranking, hooking ends and binding with and inlcuding MS wire (annealed) not less than .9mm dia complete all as specified and as directed |
| 187 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets, complete all as specified and directed. |
| 188 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. including 6mm dia GI hangers including S&F Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including applying 3 mm wall care putty and applying two coats of oil bound distember over a coat of primer, complete all as specified and directed. |
| 189 | Necessary arrangement forTransporting Diesel (DHPP N) issued from AGE E/M -IIunder GE (U-II) Visakhapatnam Office address to NCN Kakinada (Approx 175 km) as per requirement, complete all as specified and directed.Note:- Capacity for transportation is 200 Ltrs to 600 Ltrs . |
| 190 | Dismantling the existing unserviceable LT UG cable and Supply & layingin trenches or fixing on wall or passing through pipe or in cable ducts LT UG cable XLPE insulated and armoured, with aluminium conductor,LT 1100 Volts grade of following sizes, complete all as specified and directed:- |
| 191 | 16 sqmm 4 core. |
| 192 | 25 Sqmm 3.5 core |
| 193 | 35 sqmm 3.5 core. |
| 194 | 95 sqmm 3.5 core |
| 195 | 120 sqmm 3.5 core |
| 196 | Supply and laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm including taking down old one, complete all as specified and directed. |
| 197 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm incl taking down old one, complete all as specified and directed. |
| 198 | Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed. Note : Punned thickness shall be measured. |
| 199 | M&Lfor Fly Ashcompact bricks locally availableof size 23 x 11 x 7cm laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and directed. |
| 200 | M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete with taking down old unserviceable one, complete all as specified and directed. |
| 201 | Disconnecting the HT/LT Connections including drain out of oil in barrels and kept aside for reuse and lifting with craneincluding transportation of transformer of capacity upto 200 KVA and oil etc to civil workshop for necessary repair works, complete all as specified and directed. |
| 202 | Dismantling of transformer up to 200 KVA for repairremoving & lifting of top plate of transformer burnt oil seal/ stud nut bolt HT bushing off load tap changer butholz relay gate valve dead plug etc for repair to core and winding including taking out the same & replacing with new and repair for minor leakages (if any) and fixed the same complete including top up the oil after dehydration, complete all as specified and directed.Note:- The Winding, dehydration of oil, new Oil and other accessories shall be measured and paid for separately. |
| 203 | Repair to unserviceable core & windings of 200 KVA transformer and testing for serviceability and rewinding the same with fresh winding including insulation paper etc and keeping the same in to the hot air oven till the moisture is removed & insulation resistance improves to the satisfaction level, refixing the same in original position, complete all as specified and directed.Note :- (i) One year warranty certificate should be submitted to the Dept after completion of Job.(ii) All kind of test as per IS 2026 shall be done at workshop and certificate shall be submitted before commissioning.(iii) Any defect during defect liablity period shall be rectified by the contractor without any extra cost to the Dept. |
| 204 | M & L for painting with two coats of DUCOenamel paint of ICI brand of approved colour over a coat of red oxide metal primer after scrapping thoroughly the existing corroded paint,dirt/dust, oil and grease from the steel surface of the 200 KVA transformer, complete all as specified and directed. |
| 205 | Supply and fix transformer off load tap changer suitable for 200 KVA transformers 11 KV/433 volts transparent type including removing the existing u/s one, complete all as specified and directed. |
| 206 | Supply & filling the new transformer oil of rupturingcapacity 50KV for 60 Sec for topping up to required level of transformer with approved make, complete all as specified and directed. |
| 207 | S & F silica gel dark blue type laboratory grade in the transformer including removing the old U/S one, complete all as specified and directed. |
| 208 | M & L for filtration of the existing transformer oilof any make of transformer and capacity upto required dielectric strength as per IE rules and refilling in the transformer upto required level, complete all as specified and directed.Note:- The diectric strength should not be less than 50 KV after filtration process. |
| 209 | Supply and fix transformer breathers transparent of standard size suitable for 200 KVA transformers 11 KV/433 volts transparent type including removing the existing u/s one, complete all as specified and directed. |
| 210 | Supply and fix transformer oil temperature gauge of standard size suitable for 200 KVA transformers 11 KV/433 volts analogue type including removing the existing u/s one, complete all as specified and directed. |
| 211 | Supply and fixing of HT bushing 11 KV incl gasket nut bolts etc complete suitable for any type of transformer inclremoving the existing u/s one, complete all as specified and directed. |
| 212 | Supply and fixing of brass LT studs incl gasket nut bolts insulator etc complete suitable for any type of transformer inclremoving the existing u/s one, complete all as specified and directed. |
| 213 | M & L for defective / burnt out compressor from inverter type Split type air conditioner/Casette type of upto 2.0 ton capacity in situ or at workshop and providing new compressor Rotary / Reciprocating for the job, complete all as specified and directed.[Make: OEM or any equivalent approved make]Note:-The rate quoted Shall be included of full charging withrefrigerant gas , all electrical connection,testing and commissioning , cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, terminals etc as required. |
| 214 | M & L for defective / burnt out compressor from VRF type air conditioner/Casette type of upto 4.8 ton capacity in situ or at workshop and providing new compressor Rotary / Reciprocating or any other type for the job, complete all as specified and directed.[Make: OEM or any equivalent approved make]Note:-The rate quoted Shall be included of full charging withrefrigerant gas , all electrical connection,testing and commissioning , cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, terminals etc as required. |
| 215 | S&F in repairs Set Free Spares Main PCBA for VRF type AC of Capacity 4.8 TR , complete all as specified and directed. |
| 216 | S&F in repair ODU fan lower along with motor for VRF type AC of capacity 4.8 TR, complete all as specified and directed. |
| 217 | S&F in repair PCB for VRF Split AC,ODU fan ,ODU reactor for VRF type AC of capacity 4.8 TR, complete all as specified and directed. |
| 218 | S&F in repairs Sensors both outdoor and indoor unit for VRF type AC of capacity 4.8 TR, complete all as specified and directed. |
| 219 | Supply and charging of refrigerant gas suitable for Package type / split air conditioners /cassete type/VRF Air cooled plant, complete all as specified and directed.[Make: Floron / Mafron / Refron / National] |
| 220 | M & L for leak testing with N2 gas of indoor/outdoor unit upto 4.8 TR capacity, rectification of leaks by welding / brazing and pressure testing as per the standards and holding the pressure for 24 Hrs and observe for any pressure drop in the system including evacuation with vaccum machine , complete all as specified and directed.Note:-The rate quoted shall be inclusive of full charging withrefrigerant gas after leakage rectification,testing and commissioning , cost of cutting, brazing , sealing the refrigeration tubing,Cleaning and servicingetc. |
| 221 | Supply and replace in repairs unserviceable indoor unit (inverter/non-inverter) blower fan motorupto 2.0 Ton capacity Split air conditioner/casette AC with new fan motorsuitable for air conditioners 800 to 1250 RPM including testing , complete all as specified and directed.[Make: OEM or any equivalent approved make] |
| 222 | All as per Srl item no 180.00 here-in-before but for 4.8 TR capacity Split air conditioner/casette AC. |
| 223 | Supply and replace in repairs unserviceable outdoor unit (inverter/non-inverter)fan motorupto 2.0 Ton capacity Split air conditioner/casette ac with new fan motorsuitable for air conditioners 800 to 1250 RPM including testing , complete all as specified and directed.[Make: OEM or any equivalent approved make] |
| 224 | All as per Srl item No 182.00 but for 4.8 TR capacity Split air conditioner/casette AC |
| 225 | Supply and replace unserviceable blower fan blade for hot air / cool air suitable for split type air conditioner/casette upto 2.0 Ton capacity, balancing for smooth rotation in the casing and testing, complete all as specified and directed.Make: Magic / National / CG / Usha |
| 226 | Supply and replace unserviceable blower fan blade for hot air / cool air suitable for floor mounted / tower model split type air conditioner upto 3.0 - 5.0 Ton capacity, balancing for smooth rotation in the casing and testing, complete all as specified and directed.[Make: Magic / National / CG / Usha] |
| 227 | Supply and replace old defective running capacitors with new capacitors 50 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners, complete all as specified and directed.[Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
| 228 | Supply and replace old defective starting capacitors with new capacitors 100-120 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners, complete all as specified and directed.[Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
| 229 | Supply and replace unserviceable copper condensation coil upto 2.0 Ton capacitysplit type/casette air conditioner including testing, complete all as specified and directed. |
| 230 | Supply and replace unserviceable Evaporator coil upto 3.0 Ton capacity window / split type /casette air conditioner including testing, complete all as specified and directed. |
| 231 | Supply and replace unserviceable single phase contactor suitable for Split air conditioners upto 2.0 Ton capacity , complete all as specified and directed.[Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH] |
| 232 | M & L for servicing in situ of Air conditioners (indoor unit and outdoor unit complete) of any make and capacity with electrical blower , cleaning with castic soda and soap water to all the parts including evaporator , condenser , grills, etc and checking of all the electrical connections, etc, complete all as specified and directed. |
| 233 | M & L for rewinding of unserviceable blower motor (indoor unit) / fan motor (outdoor unit) of any capacity Split type AC/casette AC,including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing, complete all as specified and directed. |
| 234 | Repairs to defective printed circuit board of Split AC (inverter/non-inverter)/ Window AC r of 230 Volts single phase any capacity, complete all as specified and directed. |
| 235 | Supply and replace unserviceable Electronic Printed Circuit board for inverter type Split AC/casette AC of existing capacity for outdoor unit, complete all as specified and directed. |
| 236 | Supply and replace unserviceable Electronic Printed Circuit board for inverter type Split AC/ casette AC of existing capacity for indoor unit, complete all as specified and directed. |
| 237 | Supply and replace unserviceable coil sensor/room sensor for inverter type Split AC of 1.5/2.0/3.0 Ton capacity for indoor unit , complete all as specified and directed. [Make: OEM or any equivalent approved make] |
| 238 | Supply and fix copper tubing 24 SWG of size5/8\" along with tubular insulation suitable for Split AC, complete all as specified and directed. |
| 239 | Supply and replace Split AC Valves made of high grade free cutting brass and copper for pipe of size 1/2\", 1/4\", 3/8\" and 5/8\", complete all as specified and directed. |
| 240 | M & L for cutting and removing rusted steel body of Split AC / Window AC / Water coolers of any type and welding new MS sheet of suitable gauge including necessary bending as required and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.[Make: ASIAN / SHALIMAR / BERGER / J & N] |
| 241 | Supply and replace copper capillary tube suitable for Split AC of 1.5 / 2.0 Ton capacity, complete all as specified and directed. |
| 242 | S & F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete including one MCB, SPN, 20 Amps, 240 volts, 10 KA, complete all as specified and directed. |
| 243 | Supply and replace electronic remote control with hand set compatible for Split AC of 1.5 / 2.0 Ton capacity of existing make and model, complete all as specified and directed. |
| 244 | Supply and replace thermal insulation for indoor to outdoor copper pipe suitable for split type AC of any capacity, complete all as specified and directed. |
| 245 | Supply and replace indoor unit of split type Air conditioner 2.0 Ton/ casette AC of existing capacity suitable for existing outdoor unit, complete all as specified and directed.[Make: BLUE STAR / HITACHI / VOLTAS / CARRIER] |
| 246 | Supply and replace outdoor unit of split type Air conditioner 2.0 Ton/ casette AC of existing capacity suitable for existing outdoor unit, complete all as specified and directed.[Make: BLUE STAR / HITACHI / DAIKIN / CARRIER] |
| 247 | Supply only insulation of copper pipes of DVRF/Ductable/Package AC system, completeall as specified and directed. |
| 248 | Taking down carefully aluminium/copper point wiring (light/fan/socket/power)including fittings such as switches, socketceiling roses, pendants, regulators etcand removing unserviceable materials from site and making good disturbed surfaces of walls/floors and reuse the serviceable fittings under respective items, complete all as specified and directed. |
| 249 | M & L forpoint wiring with 1.5 Sq mm (Nominal area) PVC insulated and unsheathed 1.5 sq mmcable of 1100V grade with stranded copper conductor in and including PVC Capping & Casing/PVC conduit/concealed type,casing accessories along with continuous earth wire of1.5 Sq mm PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly with and including 1.6mm thick cadmium plated sunk MS pressed steel terminal boxes(or existing sunk boxes) with 3.0 mm thick hylam sheet cover fixed with brass screw complete with all accessories for one light point/Fan point/call bell point controlled by one ,one way switch, complete all as specified and directed. |
| 250 | Allas per Srl ItemNo 208.00 mentionedhere-in- above but one 3 pin 5 Amps socket out let on the same boardwith other switches with 1.5 sq mmPVC insulated copper conductor for continuous earthing complete. |
| 251 | Allas per Srl itemNo 208.00 mentionedhere-in-abovebut one 3 pin 5 Amps socket out let on independent boardwith 1.5 sq mmPVC insulated copper conductor for continuous earthing complete. |
| 252 | Allas per Srl item No 208.00 mentionedhere-in- before but 3 pin15 Ampssocket outleton independent board with 4 sq mmPVC insulated and sheathed copper conductor with 1.5 sq mm PVC insulated copper conductor single corefor continuous earthing complete. |
| 253 | M & L forSwitch piano flush type single pole one way 6 Amp, complete all as specified and directed. |
| 254 | M & L for Switch socket combination2 in 1, 3 pin, 6 Ampsflush type, complete all as specified and directed. |
| 255 | M & L forSocket outlet 2 in 1, 3 pin, 6 Amps flush type, complete all as specified and directed. |
| 256 | M & L forSwitch socket combination2 in 1, 3 pin, 6 Amp and16 Amps flush type universal, complete all as specified and directed. |
| 257 | M & L forceiling rose, surfaces Bakelitethree terminals, complete all as specified and directed. |
| 258 | S & F wall mounted LED 18 watts, 4 feet,of colour temperature 2700 K (warm white), Batten slimtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements and connection from ceiling rose to fitting completeincluding dismantling the existing unserviceable fitting, complete all as specified and as directed. |
| 259 | S & F Recess mounted Environmental friendly, asthetically designed, high performance, round shape back lit downlighter 15W in roboust PDC aluminium housing with high brightness SMD LED as Light source,suitable for Armstrong /Grid ceiling, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting includingsuitable LED driver, complete all as specified and directed. |
| 260 | S & F IP 65 Rated LED Post Top light with moonlight effect, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from control DBto fitting includingsuitable LED driver, complete all as specified and directed. |
| 261 | S&F LED light fitting 1 X 9 watts, 230 V decorative wall mounting type, made up of Polycarbonate with 1 x 9 LED and lamp holder, connector block, etc complete with all accessories prewired and including connecting up with twin core 1.5 sq mm flexible copper conductor cable, complete all as specified and directed. |
| 262 | M & L sheet metal enclosure IP43 for DBs 6 way double door acrylic cover type with 200amps rated busbar TPN including necessary connectionafter and including taking down old Unserviceable one, complete all as specified and directed. |
| 263 | M & L sheet metal enclosure for DBs 4 way double door type with 200amps rated busbar SPN including necessary connectionafter and including taking down old Unserviceable one, complete all as specified and directed. |
| 264 | All as per Srl item No 222.00 here-in-before butfor 8 way. |
| 265 | M & L forMCB single pole 6 to 32 Amps 240 V\"C\" series ,Breaking strength 25 KA, after and including taking down old Unserviceable one, complete all as specified and directed. |
| 266 | M & L for MCB Double Pole 32Amps 240 V , Breaking Strength 25 KA, after and including taking down old Unserviceable one, complete all as specified and directed. |
| 267 | M & L for MCB Double Pole 40Amps 240 V, Breaking Strength 10 KA after and including taking down old Unserviceable one, complete all as specified and directed. |
| 268 | M & L for sub main wiring with two single core PVC insulated cable with Copper conductor unsheathed cable of size 6 sqmm drawn through & including PVC casing capping with 4 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unserviceable one, complete all as specified and directed.Note : Two run 6 Sq mm & One run 4 Sqmm of cable shall be measured as single run. |
| 269 | M & L for sub main wiring with two single core PVC insulated cable with Copper conductor unsheathed cable of size 4 sqmm drawn through & including PVC casing capping with 2.5 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unserviceable, complete all as specified and directed.Note : Two run 4 Sq mm of cable and One 2.5 Sqmm cable shall be measured as single run. |
| 270 | M&L for rewinding the submersible motor upto 5 HP capacity PVC insulated copper conductor of same gauge and same number of turns as that of existing including tieing the winding and connecting the coils and bringing the connections as that of existing, complete all as specified and directed. |
| 271 | SCHEDULE OF CREDITNote :- Amount of Rs. 1,36,881.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail