| 1 | NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE(a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after.(b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor.(c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher.(d) The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE. |
| 2 | NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE(e)The breakdown/Leakegesshould be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues:Size of Pipe Time limit to attend Breakdown& CompletionUpto 50mm 6 Hrs50mm-100mm 8 HrsMore than 100mm 12 Hrs(f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement.(g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multistoried Buildings under AoR of GE (U-II). |
| 3 | Labour only for attending break down of 200/150 mmdia MS / CI / DIpipe line bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering by using necessary dewatering pumps, JCB\"s, Cranes etc, complete all as specified and directed by Engr-in-Charge.Note 1 :- The quoted rate shall deemed to be inclusive of the following:-(i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii)Labour element required for fixing CI/DI/MS pipes, specials, fittings etc.Note 2 :- Earth work,Lead joints, Supply onlypipes, specials, fittings shall be measured and paid seperately under relevant items. |
| 4 | All as per Item No. 02 here-in-before butfor 100/80 mm dia. |
| 5 | Supply only 100mm dia size of spigot and socket end Ductile Iron pipe class K 9 ISI marked as perIS 8329-2000 with centrifugally lined with cement mortar with flexible rubber gaskets push on type joints, complete all as specified and directed by Engr-in-Charge. |
| 6 | All as per Srl No 04 above but of size 150 mm dia. |
| 7 | All as per Srl No 04 above but of size 200 mm dia. |
| 8 | M&L for run lead joint for spigot and socket CI Pipes and fittings of size 100 mm,complete all as specified and directed. |
| 9 | All as per Srl No 07 above but of size 150 mmbore. |
| 10 | All as per Srl No 07 above but of size 200 mmbore. |
| 11 | Supply only DI Specials (any type radius and angle) tapers any type straight increasing decreasing or double socket and \"\"Y junction double branch, Collar, cross (allsockets or socket and spigot)caps and plugs upto 300 mm bore,complete all as specified and directed. |
| 12 | M & L for re-conditioning of battery 12/24 Volts, 90/180 AH complete including replacement of lead plate terminal and joints and charging of battery and Improve specific gravity upto 1280 and 2 volts of each cell including transportation of battery from site to civil work shop and back, complete all as specified and directed by Engr-in-Charge. |
| 13 | M & L for replacement of battery lead sets of two (Red & Black) suitable for 180 to100 AH capacity upto 1.5 mtr long including GM terminals one end copper lug and other fixtures connecting both end with gun metal terminals as per existing, complete all as specified and directed. |
| 14 | M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point and including taking down existing earthing complete all as specified or indicated including testing on completion, complete all as specified and directed. NOTE:- The quoted rate shall deemed to be inclusive of earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4, type B1 cover 50 mm thick with 8 mm dia TMT bar @ 140 mm C/C, GI watering pipe 20 mm bore medium grade, funnel, wire mesh and earthing lead upto 7.5 m. |
| 15 | M & L for disconnecting the delivery pipeline and electric connections of submersible pump set of capacity of 3 to 7.5 HP and lifting and removing it from its position along with pipes and fittings carefully with the help of required T&P and transporting the same to the work shop for repair / servicing and lowering and refixing the same in its original position including connecting up of water and electric connections including testing and commissioning, complete all as specified and directed. |
| 16 | M & L flushing of existing borewells of size upto 150 mm dia, depth upto 90 mtr with drilling compressor including surging and flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air and flushing the sand, mud etc from the bore well till discharge of the fresh water, complete all as specified and directed. |
| 17 | M & L for rewinding the submersible motorof 3 to 7.5 HP capacity with PVC insulated copper conductor of same gauge and same number of turns as that of existing including tieing the winding and connecting the coils and bringing the connections as that of existing, complete all as specified and directed. |
| 18 | M & L for rewinding the submersible motorof 15 HP capacity with PVC insulated copper conductor of same gauge and same number of turns as that of existing including tieing the winding and connecting the coils and bringing the connections as that of existing, complete all as specified and directed. |
| 19 | M & L for opening the submersible pump set of 3 to 7.5 HP for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surface, making the pump and motor fully serviceable including lathework etc and testing the same for satisfactory operation on its full load, complete all as specified and directed by Engineer - in - Charge. Note: -The quoted rate shall be inclusive of spares required for replacement such as Thrust bearing set, Impeller, Shaft Key, Stage casing, Neck ring stage casing, sand guard, Middle sleeve, diffuser etc. |
| 20 | M & L opening the submersible pump set of 15 HP for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surface, making the pump and motor fully serviceable including lathework etc and testing the same for satisfactory operation on its full load, complete all as specified and directed by Engineer - in - Charge. Note:- The quoted rate shall be inclusive of spares required for replacement such as Thrust bearing set, Impeller, Shaft Key, Stage casing, Neck ring stage casing, sand guard, Middle sleeve, diffuser etc. |
| 21 | S & F in repair, submersible pump starter suitable for AC 415 Volts, 50 Hz, 3 Phase submersible pump set of 3 to 7.5 HP capacity, having single phase protection, over / under current protection, Auto ON / OFF timer control, including mounting on existing arrangements and removing the old unserviceable starter from the panel, complete all as specified and directed by Engineer - in - Charge. |
| 22 | S & F in repair, submersible pump starter suitable for AC 415 Volts, 50 Hz, 3 Phase submersible pump set of 15 HP capacity, having single phase protection, over / under current protection, Auto ON / OFF timer control, including mounting on existing arrangements and removing the old unserviceable starter from the panel, complete all as specified and directed by Engineer - in - Charge. |
| 23 | M & L for repair & overhauling of squirrel cage induction electrical motor of following capcities, 3 phase, 415 volts incl disconnecting all electrical connections, decoupling from pump, taking down the motor from foundation, cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump, checking alignmentconnecting all electrical connections, checking the vibrations, RPM, DOR, painting with one coat of synthetic enamel paint after preparing the surfaces and testing on full load, complete all as specified and directed by Engineer - in - Charge:-Notes:- The cost of U/S parts such as Bearings DE & NDE, Pump Shaft Sleeves & Shaft, new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts shall be deemed to be included in quoted rates. |
| 24 | 100 HP |
| 25 | 40 HP |
| 26 | 30 HP |
| 27 | 25 HP |
| 28 | 20 HP |
| 29 | M & L for repair & overhauling of centrifugal pump set of following capacities and of any make, dismantling and taking down pump after disconnecting water supply connections, decoupling from motor removing out impeller, cleaning, descaling, greasing to bearings incl replacement of unserviceable parts such as bearings DE & NDE, pump shaft sleeves, coupling pully, pump shaft etc.Assembly in the pump with new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts and coupling with motor checking for vibration & alignment connectingdelivery and suction pipe, painting with one coat of synthetic enamel paints testing the pump set, complete all as specified and directed by Engineer- in-Charge:-Notes:- The cost of U/S parts such as Bearings DE & NDE, Pump Shaft Sleeves & Shaft, new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts shall be deemed to be included in quoted rates. |
| 30 | 100 HP |
| 31 | 40 HP |
| 32 | 30 HP |
| 33 | 25 HP |
| 34 | 20 HP |
| 35 | M & L for repair & overhauling of monoblock pump set of following capacities, taking out impeller, cleaning, descaling & greasing to bearings incl replacement of unserviceable parts such as bearings DE & NDE, gland flange,etc. Cleaning and varnishing the stator and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignmentconnecting all electrical / water connections, checking the vibrations & alignment, RPM, DOR, painting with one coat of synthetic enamel paint after preparing the surfaces, testing the pump set on full load, complete all as specified and directed by Engineer- in-Charge:-Notes:- The cost of U/S parts such as Bearings DE & NDE, Pump Shaft Sleeves & Shaft, new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts shall be deemed to be included in quoted rates. |
| 36 | Monoblock pump set 15 HP |
| 37 | Monoblock pump set 12.5 HP |
| 38 | Monoblock pump set 10 HP |
| 39 | Monoblock pump set 05 HP |
| 40 | Monoblock pump set 03 HP |
| 41 | S & F Teflon Gland Packing Rope, for Industrial use of size 05 mm to 50 mm thick superior quality for centrifugal / monoblock pumps, complete all as specified and directed. |
| 42 | M&L for replacement of pumpset coupling pully with rubber band, nuts and bolts for the following capacity, complete all as specified and directed:- |
| 43 | 75 HP to 90 HP |
| 44 | 40 HP to 60 HP |
| 45 | 20 HP to 30 HP |
| 46 | M & L for Servicing / maintenance of dial type water level indicator by replacing wornout central movement plate, counter weight, centre diving wheels etc and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and as directed. |
| 47 | M & L for arresting water leakage fromsluice valve of 80 mm bore, byrefacing, regrinding of sluice Valve, Repacking stuffing box of sluice valve spindle including taking apart and reassembling the same including replaceing oldcheck nuts with new onemade out of MS / CI material, with and including replacing perished gland packing, rubber gasket, bolts and nuts, complete all as specified and directed. |
| 48 | All as per Srl. Item No.28 above butfor 100 mm bore. |
| 49 | All as per Srl. Item No.28 above but for 150 mm bore. |
| 50 | All as per Srl. Item No.28 above but for 200 mm bore. |
| 51 | Supply and replace CI sluice valves, 150 mm dia , PN 1.0, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc, complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply and replace CI sluice valves, 100 mm dia , PN 1.0, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc, complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply and replace CI sluice valves, 80 mm dia , PN 1.0, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc, complete all as specified and directed by Engineer-in-charge. |
| 54 | S& F in replacement GI tubing of 20mm dia, medium grade, with all fittings, complete fixed to walls and ceiling or laid in trenches / floors, complete all as specified and directed by Engineer-in-charge. |
| 55 | S& F in replacement GI tubing of 25mm dia, medium grade, with all fittings, complete fixed to walls and ceiling or laid in trenches / floors, complete all as specified and directed by Engineer-in-charge. |
| 56 | S& F in replacement GI tubing of 40 mm dia, medium grade, with all fittings, complete fixed to walls and ceiling or laid in trenches / floors, complete all as specified and directed by Engineer-in-charge. |
| 57 | S& F in replacement GI tubing of 50mm dia, medium grade, with all fittings, complete fixed to walls and ceiling or laid in trenches / floors, complete all as specified and directed by Engineer-in-charge. |
| 58 | S& F in replacement GI tubing of 80mm dia, medium grade, with all fittings, complete fixed to walls and ceiling or laid in trenches / floors, complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply and fixing in repair gun metal gate valve of 20mm dia, with iron wheel head,screwed both ends, class II, and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fixing in repair gun metal gate valve of 25mm dia, with iron wheel head,screwed both ends, class II, and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and fixing in repair gun metal gate valve of 40mm dia, with iron wheel head,screwed both ends, class II, and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply and fixing in repair gun metal gate valve of 50mm dia, with iron wheel head,screwed both ends, class II, and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply and fixing in repair gun metal gate valve of 80mm dia, with iron wheel head,screwed both ends, class II, and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply, laying PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 3 core 4 Sq mm including taking out old un-serviceable cable, complete all as specified and directed. |
| 65 | Supply, laying PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 3 core 10 Sq mm including taking out old un-serviceable cable, complete all as specified and directed. |
| 66 | Supply, laying PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 3 core 16 Sq mm including taking out old un-serviceable cable, complete all as specified and directed. |
| 67 | Supply & replacement of water level indicator, 36\" dia for OHT/UG sump as per IS and including numbering with radium stickering, heavy duty float, counter weight, heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge. |
| 68 | M & L for painting of monoblock pump set of 3 HP to 10 HP with a coat of approved colour paint including inlet & outlet pipe lines over a coat of red oxide primer on rusted parts complete including preparation of old painted surface and writing MES number, complete all as specified and directed by Engr-in-Charge. |
| 69 | M & L for painting of Centrifugal pump set of 12.5 HP to 25 HP with a coat of approved colour paint including inlet & outlet pipe lines over a coat of red oxide primer on rusted parts complete including preparation of old painted surface and writing MES number, complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L for replacement of 3 Pole power contactor AC 415 V 110 Amps, AC3, 2 NO + 2 NC50 Hz Model No ML 6 in the existing starter, complete all as specified and directed. |
| 71 | M&L for replacement of 3 Pole power contactor AC 415 V 70 Amps, AC3, 2 NO + 2 NC50 Hz Model No ML 4 in the existing starter, complete all as specified and directed. |
| 72 | M&L for replacement of Electronic Timers Type ST 100 Time delay of3 - 30 Sec, operating Voltage 160 V to 500 V suitable for base mounting and DIN mountingin the existing starter panel, complete all as specified and directed. |
| 73 | M&L for replacement of unserviceable water pressure guage with new water presure guage round dial type suitable for 15/25/30/40/100 HP pump set including tube and stop cock, complete all as specified and directed. |
| 74 | M & L for cleaning of vegetation by using excavator for removing bushes / thick vegetation around the pump house, installations, levelling the area without damaging the pipelines / Cable network / Padestals of pipelines / buildings including disposal of the vegitation / debris material up to a distance not exceeding 50 m, complete all as specified and directed by Engineer-in-Charge. |
| 75 | Material and labour for PCC (1:3:6) type C1 using 20 mm graded stone aggregate as a surface hard standing/ base foundation for the pipelines/Chlorine plantincluding necessary form work, complete all as specified and directed.Note:- The quoted rates shall be inclusiveof levelling the surface as directed. |
| 76 | M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface mixed with water proofing compound as per manufacturer\"s instruction finished even and fair without using extra cement, complete all as specified and directed. |
| 77 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth forlaying of cables / pipesetc and getting out in any type of soil, complete all as specified and directed. |
| 78 | Returning, filling in including spreading levelling watering and well ramming in layers not exc 25 cm in any type of soil, complete all as specified and directed. |
| 79 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 80 | S & F in repair Solar Street Light luminaire wattage 30 W, >100 lumen/watt including suitable tubular pole of 5 m height mounted with inbuilt battery (LiFEP04) 12.8 V, 24 Ah, having 50 W Mono Crystalline SPV panel auto on / off of lights while dusk to dawn, complete all as specified and directed by Engineer in charge. |
| 81 | Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked in replacement , IS-15801, PP-R pipes of outer dia 75mm, SDR 7.4 (PN-16) and PP-R plain fittings in trenches / walls / cellings or laying in floors, including fittings, complete all as specified and directed. |
| 82 | Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked in replacement , IS-15801, PP-R pipes of outer dia 63mm, SDR 7.4 (PN-16) and PP-R plain fittings in trenches / walls / cellings or laying in floors, including fittings, complete all as specified and directed. |
| 83 | Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked in replacement , IS-15801, PP-R pipes of outer dia 50mm, SDR 7.4 (PN-16) and PP-R plain fittings in trenches / walls / cellings or laying in floors, including fittings, complete all as specified and directed. |
| 84 | Supply and fix in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 85 | Supply and fix flanged end lift type Foot valve 150 mm dia (Strainer for suction) with brass strainer, suitable flanges, nuts, bolts, gaskets, complete all as specified and directed. |
| 86 | Supply and fix flanged end lift type Foot valve 100 mm dia (Strainer for suction) with brass strainer, suitable flanges, nuts, bolts, gaskets, complete all as specified and directed. |
| 87 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 88 | M&L for construction of brick masonary withinternal dimension of 1000x1000x1000mm. andvalve chamber with angle iron frame and MS sheet cover3mm thick duly painted 2 coats of red oxide/ zinc chromate primer including lifting handle, locking arrangement, excavation and earth work, plastering, complete all as specified and directed. |
| 89 | M & L for repair to valve chamber of any size as in cleaning/removing debris, mud etc along with normal repaires to its existing structure as brick work in CM (1:6), 100 mm thick PCC (1:4:8) type D2 foundation, plastering internal sufaces where required and external surfaces upto 150 mm below ground level, 15 mm thick in CM (1:4)50 mm thick (1:3:6) Type C1 coping, completeincluding white washing the valve chamber, complete all as specified and directed. |
| 90 | M&L for Washing rubbing down and stopping of distempered surfaces any type of wall upto 4th floor incl preperation and then applying one coat of oil bound distemper on old plastered surface by Auto roller of any tint, complete all as specified and directed. |
| 91 | M&L Preperation of old plastered surfaces ofwall upto 4th floor and apply one coat of white wash, complete all as specified and directed. |
| 92 | M&L Preperation old painted surfaces of steel upto 4th floor and applying one coat of synthetic enamel paint ony description not other described over 10cm width or girth, complete all as specified and directed. |
| 93 | M&L for preparition of wall upto 4th floor by Vaccum based sanding machineremoval of nails etc and then apply one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm by using auto roller, complete all as specified and directed. |
| 94 | M & L for taking down cement plaster on brick wall stone wall etc including raking outjoints, hacking for key securing down with water etc, complete all as specified and directed. |
| 95 | M&L for rendering 15 mm thickin cement mortar 1:4 on other than fair face of brick or surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 96 | M&L for rendering 10 mm thickin cement mortar 1:6 on other than fair face of brick or surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 97 | M&L for applyingtwo coats 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 Lit/10 Sqm over newly plasteredby auto roller upto 4th floor surfaces incl preparation of surfaces, complete all as specified and directed. |
| 98 | M&L for preparation of newly plastered surfacesof wall upto 4th floor by Vaccum based sanding machine applying 3mm wall care putty (Multipurpose mixer shall be used for uniform and poper mixing of putty ) and applyingtwo coats ofemulsion distemper white or colouredover a coat of alkaline resistant primer by auto roller, complete all as specified and directed. |
| 99 | Supply and fixing in repair 15mm bore fancy type chromium plated bib tap cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule etc, complete all as specified and as directed. |
| 100 | Supply and fixing in repairs 10 litre capacity PVC low level flushing cisternwith all accessories complete fixed with WC including syphonic pipe, PVC flushing pipe of size 32mm dia, complete all as specified and directed. |
| 101 | Supply and fixing in repairs 15mm dia bore stop cock/angle cock, cast fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe on for unions and fixed, complete all as specified and as directed. |
| 102 | Supply and fixing in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden /plastic cleats (Minimum weight 190gms),complete all as specified and as directed. |
| 103 | S & Fin repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size(flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand, complete all as specified and directed. |
| 104 | Supply and fixingin repairs PVC connection 15mm dia and 600mm long with PTMT nuts, complete all as specified and as directed. |
| 105 | Supply and fixing in repairs 5.50mm thick of size600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 106 | Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking up or down of 20 mm dia steel tubing, complete all as specified and directed. |
| 107 | Hacking out old broken glass of any thickness/ size of any description from wooden/aluminium frame fixed with clips and putty, and Supply and fix 4mm thick ordinary Sheet glass fixed with clips and putty completed in squares in not exc 0.5 sq.m in each pane, complete all as specified and as directed. |
| 108 | Hacking out old broken glass of any thickness/ size of any description from wooden/aluminium frame fixed with clips and putty, and Supply and fix 4mm thick frosted glass fixed with clips and putty completed in squares in not exc 0.5 sq.m in each pane, complete all as specified and as directed. |
| 109 | Supply and fix in repairsStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 110 | Supply and Fix in repair floor door stopper of aluminium alloy,anodised with hard drawn steel spring of length 150mm, complete all as specified and as directed. |
| 111 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not hacking) removing serviceable tiles to stores and rubbish off premises, complete all as specified and as directed. |
| 112 | Material and labour Dark shade/ Double charged/Ultra charged Virified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding Screed bed or bedding layer of mortar 15 mm thick in CM 1:6for laying floor finishes, complete all as specified and as directed. |
| 113 | All as per Srl item No.91.00 above but in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding backing coat of 10 mm thick in CM 1:4on brick walls for skirting/DADO. |
| 114 | S&F 20 mm diaballvalves, PTMT high pressure of epoxy coated Aluminium rod and high density plastic ball (200 gms) complete, screwed for iron pipes or brasas ferrule and fixed, complete all as specified and directed. |
| 115 | SCHEDULE OF CREDITNote :- Amount of Rs. 1,87,180.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ. |