| 1 | Schedule \"A\" Part-I (Building Work) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 2 | Construction of RCC UG Sumpof capacity 11,500 Gallon complete all as specified and shown on drawing. |
| 3 | Schedule \"A\" Part-II (External Electrification works) |
| 4 | Total amount of Sch \"A\" Part-II (External Electrification works) brought forward from srl page No-22 |
| 5 | Schedule \"A\" Part-III (External Water supply works) |
| 6 | Total amount of Sch \"A\" Part-III (External Water supply works) brought forward from srl page No-24 |
| 7 | Schedule \"A\"Part-IV (Misc Items of Works) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 8 | Supply, fixing ,installation, testing and commissioning of LT electric paneltotally enclosed ( Factory fabricated ) CPRI approved outdoor type, double door powder coated inside & outside made of CRCA sheet not less than 3.15mm thick with front opening having locking arrangement spray painting internally/externally. including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 HZ consisiting of copper bus bar of capacity 100Amps and consisting of the following:-INCOMING(a) MCCB 63 Amps adjustable thermal and fixed magnetic setting with 4 pole 35 KA - 01 No.(b) Digital multifuction meterwith 4 digital LED display -01 No(c) Indicating lamp LED type one set RYB.(d) Internal wiring with PVC insulated copper conductor multistranded cable 1100 volts grade IS 694 marked of appropriate gauge including copper lugs. OUTGOING (a) MCCB40Amps adjustable thermal and fixed magnetic setting with 4 pole, 35 KA - 01 Nos.(b) 10 Amp ,SPN MCB of 10 KA Rupturing capacity\"C\" Series -01 Nos ( C) Changover switch cap 63 Amp ,4 Pole 415V onload type |
| 9 | Supply, fixing ,installation, testing and commissioning of LT electric paneltotally enclosed ( Factory fabricated ) CPRI approved outdoor type, double door powder coated inside & outside made of CRCA sheet not less than 3.15mm thick with front opening having locking arrangement spray painting internally/externally. including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 HZ consisiting of copper bus bar of capacity 100Amps and consisting of the following:-INCOMING(a) MCCB 100 Amps adjustable thermal and fixed magnetic setting with 4 pole 35 KA - 01 No.(b) Digital multifuction meterwith 4 digital LED display -01 No (c) Indicating lamp LED type one set RYB.(d) Internal wiring with PVC insulated copper conductor multistranded cable 1100 volts grade IS 694 marked of appropriate gauge including copper lugs. OUTGOING (a) MCCB 63 Amps adjustable thermal and fixed magnetic setting with 4 pole, 35 KA - 01 Nos. (b) MCCB 40 Amp4 pole 35 KA -01 Nos for Submersible Pump Motor ( c) 10 Amp ,SPN MCB of 10 KA Rupturing capacity\"C\" Series -01 Nos ( D) Changover switch cap 100 Amp ,4 Pole 415 Volts onload type. |
| 10 | Supplying, installing, testing & commissioning of factory assembled Diesel Engine withdriven generating set coupled withalternator AC to give continuous output of 58.5 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine, watercooled, mounted on common base frame complete with in built fuel tank (service tank) of adequatecapacity with fuel line, built in electronic governor & accessories, PCC foundation work as per manufacturer\"s instructions, vibration damper pads,control panelshowing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under-mentioned technical specifications confirming to BS:5514 & IS 10000and latest CPCB norms complete in all respect with following accessories, parts all as specified & directed.(a) DIESEL ENGINE :4 cylinders , turbo charged watercooledat 1500 RPM under NTP conditionsIS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for one hour in 12 hrsof continuousoperationwith the following accessories(i) Radiator with blower fan or heat exchanger with guard .(ii) Pipe coupling for engine cooling system piping (iii) Corrosion inhibitor coolant(iv) Paper element filters-(i)Fuel(ii) Lube oil(iii) By Pass(vi) Fly wheel housing and fly wheel to suit |
| 11 | (vii) Engine bearing mechanism in fly wheel housing (viii) shut off coil with safety for LLOP /HWT./ Over speed.(ix) Dry type air cleaners and vacuum indicators .(x)Residentialsilencers.(xi)Stainless steel exhaust flexible bellows.(xii)Motor driven priming pump.(xiii) Electric starter.(xiv)Battery charging alternator.(xv) Exhaust piping made outof STICC class MS Pipe inclusive of all accessories and hardware , necessary supportas per manufacturer’s recommendations to sustain back pressure with rain cap(xvi) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe.(xvii) First fill of oil coolant and diesel during commission and 12 hours testing.(xviii)Interconnecting copper cabling of adequate capacity between batteries andcontroller.(xix) Fuel pipe. Fuel Tank_ 24 hours full load diesel storage capacity inbuilt fuel tank with mounting brackets factory fabricated made of MS sheet with level indicator fuel inlet , fuel outlet , air vent, drain plug,inlet arrangement filling from exterior of canopy etc.(xx) Battery :- Suitable capacity as per OEM design maintenance free battery with leads and terminal. |
| 12 | (xxi) PCC Foundation :- Civil work and PCC foundation for installation DG Set as per manufacturers instruction.(b) ALTRERNATOR : 58.5 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, ISO3046, suitable for above mentioned diesel engine complete all as specified and directed . (c) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) 63 KVA DG set to reduce noise level to 75 db (A), measuredat 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-:(i) Sound proof insulation 100mmthick Rock wool (Density 65 Kg/cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA(iv) Inner surface: 1.0 mm thick powder coated & perforated CRCA / GI sheet (v)Common base frame: ISMC 250 |
| 13 | (d) CONTROL PANEL :LT panelmadeout of 2mm thick CRCAsheets in suitable compartmentsfront openable duly powder coated for a weather proof and long lasting finishing including the following:- (i)MCCB suitaibly rated ,qty OEM recommended(Make: Legrand/Havells/L&T).(ii)Set of phase indicating lamps with HRC fuses - 01 Set.(iii)Voltmeter 96 sq.mmdigital type 0 to500 volts rangewith selector switch: 01 set(iv) Amp meter 96 sq.mmdigital type 0 to 400 Amps range with suitable CT\"s complete - 01 set.(v) KWH meter digital type (vi)Digital PF meter (vii) Set of suitable CT”s(viii) Indicating lamps for supply and load on (ix)Instrument fuses (HRC type)(x) Bottom gland plates for incoming and outing cable(xi)Circuit diagram plate( xii) on/off button switch (xiii) digital display /metar for Engine parameter |
| 14 | Supplying, installing, testing & commissioning of factory assembled Diesel Engine withdriven generating set coupled withalternator AC to give continuous output of 30 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine, watercooled, mounted on common base frame complete with in built fuel tank (service tank) of adequatecapacity with fuel line, built in electronic governor & accessories, PCC foundation work as per manufacturer\"s instructions, vibration damper pads,control panelshowing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under-mentioned technical specifications confirming to BS:5514 & IS 10000 and latest CPCB norms complete in all respect with following accessories, parts all as specified & directed. (a) DIESEL ENGINE :4 cylinders , turbo charged watercooledat 1500 RPM under NTP conditionsIS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for one hour in 12 hrsof continuousoperationwith the following accessories Make:M/S Kirloskar Engine (CPCB Norms Compliance ) / Sudhir /Cummins/Ashok Leyland (i) Radiator with blower fan or heat exchanger with guard .(ii) Pipe coupling for engine cooling system piping (iii) Corrosion inhibitor coolant |
| 15 | (iv) Paper element filters-(i)Fuel(ii) Lube oil(iii) By Pass(vi) Fly wheel housing and fly wheel to suit (vii) Engine bearing mechanism in fly wheel housing (viii) shut off coil with safety for LLOP /HWT./ Over speed.(ix) Dry type air cleaners and vacuum indicators .(x)Residentialsilencers.(xi)Stainless steel exhaust flexible bellows.(xii)Motor driven priming pump. (xiii) Electric starter.(xiv)Battery charging alternator.(xv) Exhaust piping made outof STICC class MS Pipe inclusive of all accessories and hardware , necessary supportas per manufacturer’s recommendations to sustain back pressure with rain cap(xvi) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe.(xvii) First fill of oil coolant and diesel during commission and 12 hours testing.(xviii)Interconnecting copper cabling of adequate capacity between batteries andcontroller.(xix) Fuel pipe. Fuel Tank_ 24 hours full load diesel storage capacity inbuilt fuel tank with mounting brackets factory fabricated made of MS sheet with level indicator fuel inlet , fuel outlet , air vent, drain plug,inlet arrangement filling from exterior of canopy etc. |
| 16 | (xx) Battery :- Suitable capacity as per OEM design maintenance free battery with leads and terminal(xxi) PCC Foundation :- Civil work and PCC foundation for installation DG Set as per manufacturers instruction.(b) ALTRERNATOR : 30 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, ISO3046, suitable for above mentioned diesel engine complete all as specified and directed . (c) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) 30 KVA DG set to reduce noise level to 75 db (A), measuredat 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-:(i) Sound proof insulation 100mmthick Rock wool (Density 65 Kg/cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA(iv) Inner surface: 1.0 mm thick powder coated & perforated CRCA / GI sheet (v)Common base frame: ISMC 250 |
| 17 | (d) CONTROL PANEL :LT panelmadeout of 2mm thick CRCAsheets in suitable compartmentsfront openable duly powder coated for a weather proof and long lasting finishing including the following:- (i)MCCB suitaibly rated ,qty OEM recommended(Make: Legrand/Havells/L&T).(ii)Set of phase indicating lamps with HRC fuses - 01 Set.(iii)Voltmeter 96 sq.mmdigital type 0 to500 volts rangewith selector switch: 01 set(iv) Amp meter 96 sq.mmdigital type 0 to 400 Amps range with suitable CT\"s complete - 01 set.(v) KWH meter digital type (vi)Digital PF meter (vii) Set of suitable CT”s(viii) Indicating lamps for supply and load on (ix)Instrument fuses (HRC type)(x) Bottom gland plates for incoming and outing cable(xi)Circuit diagram plate (xii) on/off button switch (xiii) digital display /metar for Engineparameter |
| 18 | M&L for valve chamber and construction of brick masonarry new valve pit chamber of size 1200mmx1200mmx1200mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin CM 1:4and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle ironframe embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. |
| 19 | supply and fixing Air release Valve Cast Ironwith two air Outlets, 80 mm dia bore and fixing Up in cast iron water supply mains, complete all as specified and as directed. |
| 20 | Supply & fixing of sintex SMC panel tank capacity 50000Ltrsquare type, made out of HOT PRESSMOULDED SHEET MOULDING COMPOUND panelsof size 1005mm x 1005mm x 75mm (flange), 1005mm x 2010mm x 75mm (flange) and 1005mm x 502mm x (flange) the flange should be perpendicular to the main surface. The shape shouldbe Trunked type for extra strength and 90 degree flanges pre drilled for bolting. All the Flanges of the 1 mt Panel should have 13 Nos. holes per sidefor fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm x 75mm should be provided for 90 degree joints of tanks wall to roof jointscomplete with olive green nuts, bolts and washers. Special sealent having excellentUV Resistance as well as suitable for portable water, complete with top covered construction having man hole with cover dia 600mm and internal FRP Ladder.The SMC Panelmust be ISI marked meeteing BIS 14399(part 1 & 2).Tank inlet and outlet size 80mm dia for connection of GI pipe all as specified and directed.(Make - Sintex or equivalent make as approved by GE) including cross arms works panel hight from grond level to 20feet all as directed at site. Note-:Structural work like cross arms, bracings etc shall bemeasured and paid separetlly . |
| 21 | Cleaning of site by way of bush cutting for operating theSuitable truck Mounted DTH drilling rigs along with accessories etc to the site of work & erecting of rig including leveling for required area for starting the job workall as specified & directed |
| 22 | Drilling bores of 250 mm dia using DTH rigs with ODEX attachment in collapsible strata, congiomerates, boulders, pebbles,oily clay etc including cost of T&P, consumable stores, bits, wtaer, POL with system of simultaneous lowering of casing pipes from 0 to 60 mtr depth complete all as specified and as directed. NOTE:- (i)Rates quoted by the contractor shall include cost of T&P & POL etc andconsumable (ii) In the case the reqd yield of water is not met as per requirement of CGWB department report, the bore shall be abandoned and refilled after extracting the T & P. The cost of abandoned 03 nos bore shall be admissible to the contractor @ 5% of quoted unit rate after approval of Accepting officer and no extra claim shall be admissible on this acount. The contractor shall further bore on site as selected and decided by GE.(iii)The contractor shall copmplete the work in two phases:- (a).Phase-I,Time-90 days -digging of borewell and ascertain of yield as as per CGWB report, (b).Phase-II,Time 90 days - Balance work. |
| 23 | Drilling bores of 250 mm dia using DTH rigs with ODEX attachment in collapsible strata, congiomerates, boulders, pebbles,oily clay etc including cost of T&P, consumable stores, bits, water, POL with system of simultaneous lowering of casing pipes from 61 to 180 mtr depth complete all as specified and as directed. NOTE:- (i)Rates quoted by the contractor shall include cost of T&P & POL etc andconsumable (ii) In the case the reqd yield of water is not met as per requirement of CGWB department report, the bore shall be abandoned and refilled after extracting the T & P. The cost of abandoned bore shall be admissible to the contractor @ 5% of quoted unit rate of item for per mtr depth after approval of Accepting officer and no extra claim shall be admissible on this acount. The contractor shall further bore on site as selected and decided by GE. (iii) Please also note that boring if required more that 120 mtr depthat site condition the same shall be paid under this item without any extra claim. |
| 24 | Supply, lowering and fixing ERW pipe internal dia 200mmand 7.1 mm thick including specials fittings as per requirement of ODEX attachment comforming to IS 4270:2001 complete all as specified and as directed. |
| 25 | Supplyand clamping of casing pipe assembly with clamps fabricated out ofMS flat iron of size100mmx 10mm (thick)fixed with 16mm dia nuts bolts & washers complete all as specified and as directed. |
| 26 | Collection & preservation of strata samplers in polythene bags during drilling and finally to to be kept in teakwood box of suitable size duly framed and marked complete all as specified and as directed. |
| 27 | Development of bore hole with compressor of adequate capacity and testing of yield with pumping out till clear free water is obtained from the bore by \"V\" notch as per IS-2800-1979 complete all as directed.(Note : (i) The cost of yield test and testing of water sample from Govt approved Lab/Regional Research Lab to confirm potability of water as per IS 10500-1991 shall deemed to be included in the unit rate . (ii) All equipment shall be arranged by the contractor at their own cost and nothing extra is admissible on this account. (iii) The cost of gravel initially poured in packing around the tube and amount of gravel added during development if any shall be included in the quoted of this item.. |
| 28 | Well cap fabricated out of 8 mm MS sheet including threading ,cutting ,welding all as required and provinding handle at the top of the cap complete all as specified andas directed. |
| 29 | Supply and lowering stainless steel \"V\" wire screen 200mm dia \"K\" type packet (wall thickness should not be less than 8mm) with opening 0.50mm, inside the tube well assembly in the manner with top of the assembly complete all as specified & directed |
| 30 | Supplyand Fixing suitable casing drive shoe sutable for 200 mm dia and bit tube as per requirement of depth or ODEX attachment complete all as specified and as directed. |
| 31 | Supply & Fixing pipe GI tubing heavy grade 80 mm bore duly welded flanged (thickness of flange 12mm having 04 holes) with and including rubber packing of 6mm thick, nuts, bolts, washers complete in 3 mtr length as column pipe in bore well complete all as specified and directed. |
| 32 | Design, supply, installation, commissioning and testing of submersible pump set electric driven, 415 voltscapacity 5 WHP discharge160LPMat 135 mtr headwith CI Impeller, CI diffuser, EN-8 shaft, stainless steel stainer comprising with suitable capacity of Electric motor designed for working on 415 volts, 3 Phase, 50Hz, filled with oil for effective cooling and life long lubrication of heavy duty ball bearing and mechanical seal complete with Digital electronic softstardelta starter of suitable capacity with & including protections against over load, single phase, phase sequence reversal and with sumbersible cable PVC insulated unsheathed with stranded copper conductor 1100 volts grade flat two run of 3 core 10 Sqmm for connecting of Pump to star delta starterwithout joint complete all as specifed and as directed.Note:-. Rate quoted by contractor deemed to be inclusive for the cost for calculating the capacity of submersible pump set by manufacturer ie Kirloskar/CG/KSB. In this regard a certificate along with the copy of the design of the pump by manufactrer shall be furnished by the contractor for suitability of the motor for selected pump suitable for bore as to deliver continuous water with stable LPM. 2. Rates quoted by contractor deemed to be inclusive of one set of submersible pump and conected items are installed in borewell and one set of submersible pump and connected items as stand by. |
| 33 | Design, supply, installation, commissioning and testing of submersible pump set electric driven, 415 voltscapacity 6 WHP discharge200LPMat 135 mtr headwith CI Impeller, CI diffuser, EN-8 shaft, stainless steel stainer comprising with suitable capacity of Electric motor designed for working on 415 volts, 3 Phase, 50Hz, filled with oil for effective cooling and life long lubrication of heavy duty ball bearing and mechanical seal complete with Digital electronic softstardelta starter of suitable capacity with & including protections against over load, single phase, phase sequence reversal and with sumbersible cable PVC insulated unsheathed with stranded copper conductor 1100 volts grade flat two run of 3 core 10 Sqmm for connecting of Pump to star delta starterwithout joint complete all as specifed and as directed.Note:-. Rate quoted by contractor deemed to be inclusive for the cost for calculating the capacity of submersible pump set by manufacturer ie Kirloskar/CG/KSB. In this regard a certificate along with the copy of the design of the pump by manufactrer shall be furnished by the contractor for suitability of the motor for selected pump suitable for bore as to deliver continuous water with stable LPM. 2. Rates quoted by contractor deemed to be inclusive of one set of submersible pump and conected items are installed in borewell and one set of submersible pump and connected items as stand by. |
| 34 | Supply Insttalation and testing ofcentrifugal, Pump set heavy duty with fully automatic star delta starterelectric driven,415 volt 3 phase 50 Hz.capacity 11 WHP discharge capacity of pump set should be375 LPM at 128 Mtr head.completerequired with all necessary fitting and copper cablesingle core 70 sqmm for connection from LT panel to Starteras per suitable length in three phase supply and PCC foundation with chasis complete with nut bolt and channal all as directed at side(01+01 nos stand by) |
| 35 | Supply and fixing of CI Foot valve unit, suitable for 80 mmbore conforming to IS-4038 including nuts ,bolts and washersetc fixing the same to the suction pipe of the pump set availble in the sump at a depth up to10 feet below the ground level. complete all as specified and directed. |