| 1 | Taking down the existing aluminium/copper strip/GI strip of any size and and keeping in shape custody (for serviceable strips to re-use ) complete all as specified and directed. |
| 2 | S&F galvanized iron strip 25x4 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified. |
| 3 | S&F galvanized iron strip 32x6 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified. |
| 4 | S&F aluminium strip 25x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified. |
| 5 | Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing complete all as specified. |
| 6 | S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed. |
| 7 | M&L for dismantling of PCC earth pit chamber and making PCC chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 including RCC cover with suitable size of handle including excavation and earth work as required at site complete all as specified and directed by the Engineer-in-Charge. |
| 8 | S&F in replacement of funnel with wire mesh suitable for each pit complete all as specified and directed by the Engineer-in-Charge. |
| 9 | M&L for common salt, nitrates etc for recharging of earthing pits by filling in earthing pits complete all as specified and directed by Engr-in-Charge. (Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pit after mixing in water in appropriate quantity.) |
| 10 | M&L for plate earthing completewith galvanized mild steel plate in replacement of UNSV old electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified. |
| 11 | M&L for plate earthing complete with galvanized mild steel platein replacement of UNSV electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified. |
| 12 | S&F in replacement LED street light fitting of 45 watts, 5700k, IP 66 power factor >0.95, IK-08 having 120 lm/watt efficacy with Invidia lens cover oneach LED, rendering index > 70, 4 KV integrated surge protection, external 10 KV surge protection potted driver, tougned glass cover in high pressure die-cast powder coated aluminium housing and making connection using 3 core flexible copper cable complete in replacement of old unsv light fitting against srl item No 1 all as specified and directed by Engineer -in-charge. |
| 13 | All as per srl item No.12 here-in-before but of 60 watt |
| 14 | All as per srl item No.12 here-in-before but of 70 watt |
| 15 | All as per srl item No.12 here-in-before but of 90 watt |
| 16 | All as per srl item No.12 here-in-before but of 120 watt |
| 17 | All as per srl item No.12 here-in-before but LED flood light 150 watt, 6000K |
| 18 | Note for item no. 12 to 17:-a) Operating temperature of fitting shall be -10to 50 C and voltage range of 120 V-270V.b) Make of LED shall be Cree, Nichia, Osram.c) LM-79,(not more than 1 year old) LM-80 reports for fitting are mandatory.d) The fitting shall have minimum 50000 burninghours with LM 70 report.e) BIS stamp is mandatory on fixture & driver. |
| 19 | M&L for painting to steel tubular pole 9 metre long with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc.including making yellow and black strips (30 cm width each) on pole upto 1.5 metre from the ground level and writing of pole Nos with 8 cm letter with black paint having back ground yellow as per existing complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for painting work on RCC pole with alternative strips of 30cm upto the height of 1.5 mtr from copping of the pole with two coats of synthetic enamelled paint black/white/yellow complete and painting the all accessories such as GI pipe bracket channel, clamp etc with two coats of alum paint including numbering the pole with 8cm better with black paint having back ground of yellow painted circle of 10cm dia as directed by Engr-in-Charge. |
| 21 | M&L for disconnecting of old un insulated cable of any size from JB of existing street light pole including excavation of loop and all other necessaryearth work and connection of XLPE cable with JB including thimbling, tapping as required at site complete all specified and directed. Note: Rate of thimbles/lugs will be measured and paid separately |
| 22 | M&L for reviving old unsv GI Earthing including excavation of old earthing upto GI earth plate including replacement of Existing rusted GI earth strip and protection pipe , funnel , Mesh, GI nut bolts etc all as specified and directed by Engr in Charge. |
| 23 | M&L for Thermoplastic Cable junction Boxes IP 66/67 \"weather proof\", for outdoor installation(with knockouts for cable entry) the junction box shall be insulated and made out of polycarbonate with glass fiber reinforced. The size in mm should not be less then 205x255x112. JB should be with one 6 amp SP and three phase busbar all as specified and directed by Engr-in-Charge. |
| 24 | M&L for in replacement of old rusted/UNSV bracket for fixing of street light fittings bend to shape, made out of25 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primercomplete all as specified and directed by Engr-in-charge. |
| 25 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 33,558.00 and any other reduction if any from quoted amount. |