| 1 | Excavation over areas, n exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.Note:- During the excavation, if any underground cables / external service lines obstruct, those need to be handled carefully/ without any damage to the lines/ cables. |
| 2 | All as per Sl. Item No. 1 above but exc.1.5 m and not exc. 3.0 m deep. |
| 3 | M&L PCC 1:4:8 Type D2 (40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed |
| 4 | M&L brick work with sub class `B\" bricks straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed |
| 5 | M&L RCC M-25 design mix (20 mm graded stone aggregate) as in foundations and including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, and mass concrete complete all as specified and directed. |
| 6 | All as per Sl. Item No. 5 above butin columns. |
| 7 | All as per Sl. Item No. 5 above butin beams, cantilevers, bressummers, lintels over 1.5 m span. |
| 8 | All as per Sl. Item No. 5 above butin slabs supported on walls, beams and columns in floors, roofs and in shelves and the like |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soft / loose soil complete all as specified and directed |
| 10 | Removing excavated soil n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting pointcomplete all as specified and directed |
| 11 | M&L mild steel bars (TMT bars) 10 mm dia and over cut to length, bent to shape required and including cranking, bending, spirally for hoping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia complete all as specified and directed. |
| 12 | All as per Sl. Item No. 11 above but 6 mm to 8 mm dia as in stirrups. |
| 13 | M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces complete all as specified and directed. |
| 14 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces complete all as specified and directed |
| 15 | M&L form work to sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, for fair finished surfaces .complete all as specified and directed. |
| 16 | M&L form work to soffits of suspendedslabs such as roof slabs, floorslabs, landings and similar work;not exceeding 200 mm thick(horizontal or sloping) for fair finished surfaces complete all as specified and directed. |
| 17 | M&L 20 mm thick granite jet black shade machine cut, machine polished for steps, jambs, pillars, window- cills, cooking platforms, basin top and like in cement mortar (1:4) and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite in single piece, (cut to size in rectangular / square shape), necessary grouting and fixing with wall for table top basin complete all as specified and directed. |
| 18 | M&L Dholpur stone with hammer dressed facework (with maximum depression from a straight edge held against the dressed surface not exc. 20 mm), about 40 mm high, 75 mm deep in straight courses, laid and jointed in cement and stone dust mortar 1:3, recess pointed (10 mm x 20 mm) with an admixture of white cement and Dholpur stone dust 1:1 as in vertical surfaces etc. upto a height of 10 m to match over & including 10 mm thick rendering in CM 1:4 and taking downcomplete all as specified and directed. |
| 19 | M&L glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surfaces, etc. set and jointed in neat cement slurry/paste and pointed to match the surfaces over andincluding 10 mm thick plaster in CM 1:4 complete all as specified and directed. |
| 20 | S&F monier elabana concrete tile and including ridge tiles orange or any colour size, 430 mm x 330 mm,each tiles with 10 years warranty for colourinstalltion services fixing monier roof tiles on to providedplastered slabs with necessary cement purlins, placed at 13 inch c/c in which first purlin will be placed at a distance of 11 inch with double purlin height. Followed by monier roof laying from the bottom of the roof with a maximum overlap of 75 mm -100 mm followed by fixing of ridge tile, hip starter and 4 way supported by elevated shs / rhs section with an underlay of topflex strip & finally the ridges to be fixed with tile clip as per manufacturers instructions complete all as specified and directed. |
| 21 | S&F powder coated (minimum thickness of powder coating 50 micron) aluminium anodised frame for doors, windows, ventilators with one or more rebates and including joining cleat for fixing, etc, complete all as specified and directed. |
| 22 | S&F powder coated (minimum thickness of powder coating 50 micron) aluminium anodised door shutters, aluminium section weighing 0.55 kg/m and including necessary joining cleats, glazing clips, ruber neoprene packing, handles - 2 Nos in each door, hinges, anodised aluminum snap beading screws, etc, complete all as specified and directed. |
| 23 | S&F 5.5 mm thick glass fixed in aluminium door / window / ventilator complete all as specified and directed. |
| 24 | M&L 12 mm thick pre-laminated, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to aluminium frame complete all as specified and directed. |
| 25 | S&F aluminium door closer hydraulically regulated designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 26 | S&F brass mortice lock 4 levers, vertical type size 100 mm complete all as specified and directed. |
| 27 | S&F 140 mm size floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring complete all as specified and directed. |
| 28 | S&F double rebate windows made of pre-painted steel (base steel as per IS 513 of 0.58 mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM) and including primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72 x 55 mm, centre mullion should be of 72 x 50 mm, section for fixed glass beading should be of 12 x12 mm and section for shutter should be of 52 x 25 mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20 x 40 mm. |
| 29 | The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2 nos. of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 5 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10 mm square guard bars with 6” (152.4 mm) pitch, complete for finished item of work including taking down existing steel windows and making good disturbed surfaces complete all as specified and directed. |
| 30 | M&L15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6finished even and smooth without using extra cement complete all as specified and directed |
| 31 | M&L preparition of new plastered wall surfaces and including applying two coats of OBD over a coat of alkali resistant primer laid over and including 1.5 mm thick wall care putty complete all as specified and directed. |
| 32 | M&L preparition of new plastered ceiling surfaces and including applying two coats of OBD over a coat of alkali resistant primer laid over and including 1.5 mm thick wall care putty complete all as specified and directed. |
| 33 | Excavating in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation, laying of cables etc, n. exc. 10 sq m on plan and n. ex.c 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 34 | M&L applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 1.5 mm thick wall care putty complete all as specified and directed. |
| 35 | Demolition of brickwork or stone / boulder masonry / Block masonry, built in cement mortar including facing, dressed stone work and precast concrete all quoins, arches, pillars, copingetc but excluding ashlars articles complete all as specified and directed |
| 36 | M&L framed work as in doors and gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410 or Fe-310 and including dismantling complete all as specified and directed. |
| 37 | M&L preparation of newsteel & iron surfaces of any description not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 38 | M&L 75 mm thick (compacted thickness) WBM, with coarse aggregates of grading 2 (90 to 40 mm size) or of grading 3 (50 to 20 mm size) spread, rolled and compacted by using 8 to 12 tonne power vibrator roller to gradient and camber required and including preparation of unsurfaced WBM surface (to receive BM or SDAC as applicable) and applying evenly a priming /tack coat with bituminious primer @ 10 Kg per 10 Sqm using paving bitumen VG-30 Grade and scarifyng or picking gravelled macadam or bituminous macadam surface in area not exc. 400 Sqm and depth exc. 50 mm and not exc. 100 mm complete all as specified and directed. |
| 39 | M&L bituminous premixed semi-dense asphaltic concrete 30 mm consolidated thickness with 5.5% binder content using paving bitumen of grade VG-30 penetration by weight of total mix laid using mechanical paver, rolled and compacted to required gradient and camber using power roller of capacity exc. 8 tonne but not exc. 12 tonne and includingpreparing existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bag to remove loose dirts and applying evenly a priming / tack coat with bitumen primer at 5 Kg per 10 Sqm using paving bitumen over existing black top surfaces complete all as specified and directed. |
| 40 | Note: For design purpose min. binder content is specified as 5.5%for VG-30 grade bitumen and it shall not reduce under any circumstances. During design stage, if binder content exceeds 5.5% no extra payment shall be made to contractor for excess use of binder. |
| 41 | M&L premix bituminous macadam with bitumen content 4% total weight of mixlaidrolled and compacted to required gradient and camber using paving bitumen consolidated thickness less than 75 mm completeall as specified and directed |
| 42 | M&L road marking paint of average 2.50 mm thick forroadstrips (reflective) of specified shade / colour using hot thermoplastic material by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe, heater, driven by skilled operator on road surface and including cost of materials labour, T&P, cleaning the road surface of all dirt, scales, oil grease and foreign materials etc, scrubbing out old worn out markings etc, as per manufacturers instructions complete all as specified and directed |
| 43 | M&L point wiring for one light / fan point controlled by one switch complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSHunsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall / ceilling, continous earth wire 1.5 Sqmm PVCinsulated FR-LSH unsheathed 1100 Volts multistanderd copper conductor connected to common earth and dolly, necessary modular metal flush boxes concealed in walls and modular white plate covers with frame for mounting for modular switches / sockets / fan regulators etc, for one light point controlled by one switch one way complete all as specified and directed. |
| 44 | Note: Cost of cutting chases in walls and making good for concealed wiringand cost of modular boxes with cover plates is deemed to be included in the quoted rate. |
| 45 | All as per Sl. Item No. 41 above but one 3 pin 6 Amps switch socket outlet point controlled by one switch on independent board. |
| 46 | All as per Sl. Item No. 41 above but one 3 point 6 Amps switch socket outlet point controlled by one switch on the same board. |
| 47 | All as per Sl. item No. 41 above but with cable 4 sqmm multi stranded copper FR-LSH wire, 1100 Volts grade, unsheathed for one 3 pin socket out let 16 amps on independent board including, continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade. |
| 48 | S&F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed. |
| 49 | S&F modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 50 | S&F modular socket, shuttered type, 6A - 3 pin 2 module complete all as specified and directed. |
| 51 | S&F modular switch 1 way 16A with indicator, 1 module complete all as specified and directed. |
| 52 | S&F modular socket, shuttered type, 6/16A, combined 2 module complete all as specified and directed. |
| 53 | S&F sheet metal enclosure IP-43 double door for DBs (where MCBs arereqd) SPN 240 V, for 8 ways complete all as specified and directed. |
| 54 | S&F MCB SP 06 to 32 Amp, 240 volts complete all as specified and directed. |
| 55 | S&F RCBOs SPN 40 to 63 Amps, 240 volts 50 Hz AC supply, complete all as specified and directed. |
| 56 | M&L electrical earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal GL) with top edge of the earth plate at a depth not less than 1.5 m below normal GL and including connected to GI wire4 mm dia by means of bolts, nuts, washers madeof galvanized iron connected to earthing to body of equipment /DBs, GI wire protected by 15 mm dia light grade GI pipe upto connecting point and watering arrangements with 20 mm dia GI pipe medium grade and GI funnel all as specified and shown in electrical plate No. 3. of MES Schedule (SSR) Part I complete all as specified and directed. |
| 57 | Note : The quoted rate is deemed to be inclusive of the cost of earth work exavation on any type soil and removal of surplus soil to a distance of 50 m, PCC 1:2:4 type B1 for earth pit cover 6 nos. 8 mm dia TMT bars on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50 m will measured as one unit |
| 58 | S&F 15W surface mounted 1x1 LED flat panel downlighter with high efficient LEDs & glare free opal diffuser, IP20 with integrated electronic driver including necessary connection all as specified and directed at site.Make : Havells Cat No. PLUTOSURFACE1X 1PLS15WLED840S/ LL20111-XXX-65 NE 10W of Wipro/ CCS1031065 SL 10W of CG |
| 59 | S&F LED lights fitting 1 x 20W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen / watt and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make:Cat No. STOUT MINI 1200BS 20W LED 865SPCWH of Havells / BEPC20W of Bajaj / BN100CLED 205 of Philips |
| 60 | S&F 35 W security light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 110 lumen/Watt, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry and including wall mounting with bracket arm OD 35 mm to 42 mm, necessary electrical connection to the fixture with 3 core flexible copper conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed. |
| 61 | S&F 60W Stellar LED Post Top gate light, IP 66 and IK 10 rating, suitable for pole dia 76 mm complete all as specified and directed.Make : Havells Cat No.NEBULAPT60WLED857PSYMTOPC or equivalent make of approved list. |
| 62 | S&F 15W LED updown luminaire with wall surface mounting light, IP 66 using COB LED as light source complete all as specified and directed.Make : Havells Cat No.CLIOWLS15WLED830PSYMTOTG or equivalent make of approved list. |
| 63 | S&F wall fan 240V, 400 mm sweep metal blade with all fixing arrangement complete all as specified and directed. |
| 64 | M&L sand cushioning to under ground cable with dry sand complete all as specified and directed.Note. Punned thickness of sand to be considered for measurement purpose. |
| 65 | Supply and laying burnt bricks sub class \"B\"of old size laid dry in trenches complete all as specified and directed. |
| 66 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed at site. |
| 67 | All as per Sl. Item No. 62 above but 6 Sqmm 2 core |
| 68 | S&F 10WLED BOLLARD LIGHT (Pathway Light) new generation, energy saving, environmental friendly, long life, aesthetically designed aluminium landscape, IP 66 luminaire for diffused lighting with high power LED as light source complete all as specified and directed.Make : Havells Cat No.TURINBLS10WLED830PSYMTOPC or equivalent make of approved list. |
| 69 | S&F flexi strip trica AC LED 6W tricolor strip light 50 m fixture size, energy saving, environmental friendly with optimum brightness, IP 65 along with FLEXISTRIPACIP65 POWERCORD complete all as specified and directed.Make : Havells Cat No.FLEXISTRIP50MIP65AC6W/M830V1 or equivalent make of approved list. |
| 70 | M&L electrical earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal GL) with top edge of the earth plate at a depth not less than 1.5 m below normal GL and including connected to galvanized steel strip 25 x 4 mm by means of bolts, nuts, washers madeof galvanized iron connected to earthing to body of equipment /DBs, GI wire protected by 15 mm dia light grade GI pipe upto connecting point and watering arrangements with 20 mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No. 3. of MES Schedule (SSR) Part I complete all as specified and directed. |
| 71 | Note : The quoted rate is deemed to be inclusive of the cost of earth work exavation on any type soil and removal of surplus soil to a distance of 50 m, PCC 1:2:4 type B1 for earth pit cover 6 nos. 8 mm dia TMT bars on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50 m will measured as one unit |
| 72 | Supply, install, test and commission CPRI aproved factory fabricated, outdoor type, LTfeeder pillar box made out of 3.15 mm thick CRCA sheet of size 1 M x 0.75 M x 0.35 M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening and including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland platewith suitable size zinc cromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm MS angle iron frame, 600 mm above the normal ground level with internal connection with suitable size of cable, cable lugs and cable glands, necessary PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) complete all as specified and directed comprising of the following :- |
| 73 | (a)Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelein stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b)MCCB 63 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No. |