| 1 | Excavating in soft/ disintigrated rock in trenchs n exc 1.5m in depth andn exc 1.5m widefor foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out soft/loose soil complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm (excavated material) complete all as specified and directed. |
| 4 | Removing excavated material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L Brickwork with subclass `B\" bricks,old size straight or curved on plan exc 6m mean radius, built in cement mortar1:6 complete all as specified and directed. |
| 6 | M&L 15 mm thick rendering in cement mortar 1:3 on brick work/concrete surfaces of manhole,septic tank etc finished even and smooth with out using extra cement & complete all as specified and directed. |
| 7 | M&L for providing precast RCC (20mm graded stone aggregate) as in cover slab for man hole and similar article with plain face and set in cement mortar 1:4 complete all as specified and directed. |
| 8 | M&L TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding withincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed. |
| 9 | All as per item No 08 above but 6mm dia to 8 mm dia. |
| 10 | Demolition and breaking up existing sewag SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed. |
| 11 | Demolition and breaking up existing sewage SGSW / AC pipes and the like, 200mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed. |
| 12 | S&F 100 mmDWC , pipes single socketd , in any lengthwith rubber ring joints , laid in trenches or in floorcomplete all as specified and directed. |
| 13 | S & F DWC Pipe, 150 mm bore pipes single socketd , in any lengthwith rubber ring joints , laid in trenches or in floor complete all as specified and directed. |
| 14 | S & F DWCPipe , 200 mm bore pipes single socketd , in any lengthwith rubber ring joints , laid in trenches or in floor complete all as specified and directed. |
| 15 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore complete all as specified and directed. |
| 16 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed. |
| 17 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and directed. |
| 18 | S & F FRP/GRP solid Manhole cover area or cover size n,exc 1sqm for each Manhole for composite resien double Seal manhole cover load capacity 5 MT TO 25 MTand frame of \" FIBRA \" brand with grade designated as per EN124 standared with SS-304 nut and bolt type locking arrangments covers and frame shall have top abrasion resistant layer conforming IS 15658 repairfor factry madeFRP/GRPManhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by hevy duty frame (size of the cover will be itimated by the Engineer-in-Charge) complete all as specifiedand as directed. |
| 19 | S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar worksconforming to Fe-290 Gde E-165complete all as specified and directed. |
| 20 | S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 100 mm thick rectangle in shape upto 01 sqm areaeach with hole for drain complete all as specified and directed. |
| 21 | M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as incopings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating , complete all as specified and directed.Note : Rates include for use of formwork |
| 22 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe complete all as specified and directed. |
| 23 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 150mm dia pipe complete all as specified and directed. |
| 24 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 200mm dia pipe complete all as specified and directed. |
| 25 | M&L for salt glazed stoneware gully trap, square or round moulded type \"P\", 150x150mm size complete all as specified and directed. |
| 26 | M&L for cement concrete 1:3:6 type C1 (using 20 mm gradedstone aggregate) as in surface channels, drains and bed of manhole complete all as specified and directed. |
| 27 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 28 | M & L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete complete all as specified and directed. |
| 29 | M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed. |
| 30 | M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed. |
| 31 | S&F for 100mm bore Cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints, fixed to walls etcincl taking down old pipe complete all as specified and directed. |
| 32 | S&F for 75mm bore Cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed. |
| 33 | S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected. |
| 34 | S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected. |
| 35 | Removing daberies/excavated material to a distance exceeding 1.5KM butnot exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. |
| 36 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed. |
| 37 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg. ) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 38 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base all as specified and directed. |
| 39 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigmentincl 25mm thick sand fillingcomplete all as specified and directed. |
| 40 | Labour only for 60 mm thick machine cut precast concrete inter locking paver block (M-35) grade any colour as directed by EIC /GE complete all as specified and directed.Note : Old serviceable blocks shall be reused. |
| 41 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed. |
| 42 | Labour only for 80 mm thick machine cut precast concrete inter locking paver block (M-40) grade any colour as directed by EIC /GE complete all as specified and directed.Note : Old serviceable blocks shall be reused. |
| 43 | M & L for sand filling under floors or in foundationincluding watering and consolidation complete all as specified and directed. |
| 44 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over & incl 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 45 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying offloor/sub base finishes complete all as specified and directed. |
| 46 | M & L forPCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed. |
| 47 | M&L for providing precast cement concrete (1:2:4 type B0 using 12.5mmgraded stone aggregate) louvers and jallies, 40mm thick (measured solid),including all mouldings but excluding frame, set in CM 1:4 complete all as specified and directed. Note : Pre cast frame shall be measured separately and paid. |
| 48 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 49 | M&L for rendering 15 mm thick cement plaster in CM 1:6 onbrick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed. |
| 50 | M&L, rendering 15mm thick in CM 1:4 onof brick work or concrete surfacefinish even and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 51 | M&L for Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm on new surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 52 | M & L for preparation of new plastered surface and applying three coats of white wash on ceilingetc complete all as specified and directed. |
| 53 | M&L for vitrified tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exc 1.00 Sqmin wall set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl.15mm thick screed bed in CM (1:4) for laying floor finishes having ultra/double charged/HD Vitrified tiles complete all as specified and directed. |
| 54 | M&L for Virified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqmbut n exc 0.42 sqm, in dado , skirtingetc. set and jointed in neat cement slurry over & incl15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl rubbish off the primises etc complete all as specified and directed. |
| 55 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises complete all as specified and directed. |
| 56 | S&F for GI tubing 15mm boremedium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed. |
| 57 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 58 | S&F for 75mm bore Cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints,laid in trenches or in floors etc complete incl taking down old pipe complete all as specified and directed. |
| 59 | M&L in repair of one piece closet with bowl for coupled WC with PP soft seat cover , hinges fixing accessories and accessories set of size 360x640x680 mm, strap 220 mm withsyphonic flushing cistern with necessary fittings complete all as specified and directed. |
| 60 | S&F in repair wash hand basin table top of size 600x400x175 mmvitrous China including, waste coupling & PVC waste pipe of 32 mm dia etc complete all as specified and directed. |
| 61 | S&Fin repair Toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 62 | S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings all as specified and directed. |
| 63 | S&Fix in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed. |
| 64 | S&F in repair for wall mixturer 3 in 1 system with provision for both hand shower and overhead shower with 115 mm long bend pipe, connecting legs and wall flanges (Without hand & overhead shower) complete all as specified and directed. |
| 65 | S&F for CP brass Centre hole mixer without pop up waste system with 450 mm long braided hoses, 20mm cartridge size for mixing hot and cold water screwed down for iron pipe for WHB, in repairs complete all as specified and directed. |
| 66 | S&F in repair for CP telephonic jet with all fitting and fixture for EWCs with 8 mm Dia 1.2mt length long flexible tube, complete all as specified and directed. |
| 67 | S&F for mirror cabinet PTMT of 400mm x 500 mmwith megnetic locking arrangements fixed with and inclduling chromium plated brass screws and PVC rawl plugs complete all as specified and directed. |
| 68 | S&F for Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, complete all as specified and directed. |
| 69 | S&F for Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified. Make: Jaquar Cat Part No. ACN 1131N or equivalent approved |
| 70 | S&F for Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 71 | S&F for Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified and directed. |
| 72 | S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed. |
| 73 | S&F in repair grating round 100 mm size of CP complete all as specified and directed. |
| 74 | S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm borescrewed down high pressure with crutch or butter fly handle complete all as specified and directed. |
| 75 | S& F for swan neck pillar cock fancy type 15mm chromium plated screw with iron pipe incl all fittings in repairs ccomplete all as specified and directed. |