Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | S&F false ceiling with Semi perforated 12mm thick acoustical false ceiling, (fire retardant and sound absorbent) micro regular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (Part 4) -1970 and light code description unit rate No 429 Sub Head : 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T-Gridof hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint -T runners of size 15x32mm of length 300mm, cross -T of size 15x32 of length 600mm to form grid module of size600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 grams per sqmm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall /partition with the help of plastic rawl plugs at 450mm centre to canter and 40mm long dry wall screws.The work shall be carried out as per specification, drawing and as per direction of Engr- in -charge |
| 2 | M&L for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted cement fiber board size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per at any height complete all as specified anddirected. |
| 3 | M&L for multilayer POP false ceilingin steps (in layers) as per drawingor as directed by GE at site with horizontal and verticalGI frame work including GI wire mesh and fibermesh reinforced as required including putty work for finishing smooth painting with plastic emulsion paint in two coats over primer over finished POP surface with suitable arrangement for spot light/ceiling light as per drawing andall as specified and directedby Engr-in-charge and including 10mm thickplaster of Paris ceiling (Gypsum anhydrous)to sunk or raised moulding to flat surface over metal frame work including reinforcement with GI wiremesh and GI frame work for seamless ceiling comprising of GI perimeter channel0.55mm thick with two unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ Intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approximately 900mm centre to centre with GI cleat and steel expansion fastener with and including ceiling section (not exc 1.2 mtr length) of 0.55mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long all as specified and directed.Note: Rates includes for taking down electrical fitting and refitting the same if required complete all as specified and directed. |
| 4 | S&F in position wall panelling at all heights (fire retardant and sound absorbent) with GRG ( Glass Fibre Reinforced Gypsum) panels/tiles of10 mm thick fully perforated suitable for acoustic purpose of size 595 x 595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRC 0.70 to 0.85 as per IS 8225:1987, Non combustible as per BS 476 (Part 4)-1970 and light Reflectance of 75% to 85% (Minimum), comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanising @ 120 grams per square metre including both sides) i.e vertical studs of size 48 x 34 x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel section ofnickel coated size 50 x 32 mm fixed to the floor and ceiling at 600 centres using 12 mm dia, 50 mm long wedge type expanded zinc alloy dash fasteners with 10 mm bolt. The same channel is then to be fixed in horizontal direction at 600 centre to centre so as to form a grid of 600 x 600 mm. Glass wool of 50 mm thickness is then to be inserted in the slots and finally GRG ( Glass Reinforced Gypsum) non combustible panels/tiles are to be screw fixed with self tapping pan head nickle coated mild steel screws of size 13 x 3.2 mm on this grid leaving an even groove of 1 mm between the panels. The joint between the panels are to be duly jointed and finished using recommended jointing compound and fibre joint tape roll 50 mmm wide (90 meter) roll and two coats of primer suitable for panelling as per manufacturer\"s specifications as per direction of Engr-in-charge |
| 5 | S&F for solid PVC wall panelling decorative typeconsisting of 5 mm th plain colour PVCpre-laminated sheet inclusive of solvent cement and and fixing at site on PVC frame/wooden frame as per specification and drawing, complete all as specified and directed |
| 6 | S&F for 5 mm thick PVC sheet fillets of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed |
| 7 | M&L for preparation of old surfaces of walls, and applying one coats of distemper oil emulsion, complete all as specified and directed |
| 8 | M&L Anodised aluminium frame powder coating Minimum thickness 50 micron for doors windows,with one or more rebates including cleat for fixing etc complete all as specified anddirected. |
| 9 | S & F Anodised aluminium powder coating Minimum thickness 50 micron for door shutters , aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 nos in each door,hinges, anodised alumnium snap beading, screws etc. complete all as specified anddirected. |
| 10 | Supply and fix sheet glass 5.5 mm thick of selected quality (tinted glass) exc. 0.5 sqm each extra over sheet glass, ordinary quality, if sheet glass is ground or obscured or frosted, on one side fixed to aluminium frame work with necessary rubberbeading complete all as specified and directed by Engineer in Charge,. |
| 11 | S&F 4mm thick Aluminium composit panel for partition wall including beading etc.omplete all as specified and directed by Engr-in-Charge. |
| 12 | S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg Aluminium (extruded section body) andfixed in repair complete all as specified anddirected. |
| 13 | S&F Mortice lock, vertical type, size 100 mm, 4 Levers for Aluminium door complete all as specified anddirected. |
| 14 | M & L forMachine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment laid complete all as specified and directed. |
| 15 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 16 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in , path/hardstanding/subbase etc complete all as specified and directed by EIC. |
| 17 | S&F block board,18/19mm thick decorative type, one face grade 1 quality, exterior grade, commercial type complete all as specified anddirected. |
| 18 | S&F toughned 10mm thick glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified anddirected. |
| 19 | S&F fancy type looking mirror 3 fit wide and 6 fit height and wooden frame complete all as specified anddirected. |
| 20 | S&F fancy type looking mirror 3 fit wide and 3 fit height and wooden frame complete all as specified anddirected. |
| 21 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard and dence soil complete all as specified and as directed. |
| 22 | Returning, filling in, including spreading, watering and well ramming in layers n.exc 25 cm thick using soils complete all as specified anddirected. |
| 23 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed |
| 24 | M&L forPCC type D2 (1:4:8) (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified anddirected. |
| 25 | M&L brick work with old size brick, sub class B brick straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified anddirected. |
| 26 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as specified anddirected. |
| 27 | M/L for concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, bed plates, surface channel, slightly rounded or chamfered angles and throating,and the like including necessary formwork and finishing the surface fair and even without using extra cement. |
| 28 | M & L as in repair for providing precast cement concrete type B0 (1:2:4) (using 12.50 mm graded stone aggregate) set in cement mortar (1:4) louvers and jallies 35.00mm thick (measured solid), including all moldings , complete all as specified anddirected. |
| 29 | Mild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required manhole cover, handles and rungs,, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified anddirected. |
| 30 | M & L for Preparing plastered or unplasterednew surfaces of walls/RCC Jalliand applying two coats ofExterior grade Premium Acrylic smooth paint weather proof emulsion paint of (white or tinted) includingone coat of exteriorprimer complete all as specified anddirected. |
| 31 | M & L for Preparing plastered or unplastered oldsurfaces with complete removal of existing treatmentof walls/RCC Jalliand applying two coats ofExterior grade Premium Acrylic smooth paint weather proof emulsion paint of (white or tinted) includingone coat of exteriorprimer complete all as specified anddirected. |
| 32 | M&L forframed work as in doors or gates of angle or other section with gusset plates, with Fe-290 (Gde E165) quality A complete all as specified., drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing complete all as specified anddirected. |
| 33 | M&L two coats synthetic enamel paint over a coat of red oxideprimer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified anddirected. |
| 34 | Dismantling of ceiling /wall panelling including frame work and board complete all as specified and directed |
| 35 | S&F false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns with semi perforated 12mm thick micro tegular edged GRG false ceiling tileshaving moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions by GE, Everest ceiling andgrid system Regular T-2430 or its equivalent Make of \"Ramco/Charminar/Armstrong\" |
| 36 | M &L forPVC profile for wall panellingcolour / shade as approvedsize 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and as directed |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises outside the defense area complete all as specified and directed |
| 39 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing of demolished material off the premises outside the defense area complete all as specified and directed |
| 40 | M&L for 40 mmthick PCC 1:3:6 type C2(using40 mmgraded stoneaggregate)includingmakingjoints & fillingwithsandbitumen mastic as per complete all as specified and directed |
| 41 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed |
| 42 | M&L for Screed bed or bedding layer of cement mortar (1:4) 15 mm thick for laying floor finishes complete all as specified and directed |
| 43 | All as per above itemNo 41 but onvertical surface such as skirting, including Rendering/backing 10mm thick in CM 1:4 on brick wall surfaces, other than fair faces of brick work finished even and fair to receive tiles, complete all as specified and directed |
| 44 | Demolition to stone slab and granite laid bedded and pointed in any mortar of any description or thickness in floors/pavings/cladding etc and removing the debries outside the MOD land complete all as specified and directed |
| 45 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over 15mm thick screed of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and incl providing edge moulding complete all as specified and directed |
| 46 | Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed |
| 47 | Removal of excavated (soil) and bldg material (stone/cement mortar/concrete/etc) for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises on desecration of Contractor, complete all as specified and directed |
| 48 | Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed |
| 49 | M&L for rendering 10mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed |
| 50 | M&L for rendering 5mm thickin CM 1:3 on ceiling surfaces finished fair and even smooth without using extra cement complete all as specified and directed |
| 51 | M&L for Providing and applying (1 to 2) mm thick wall care putty on wall plastered surface/concrete surface and prepare the surface even and smooth complete all as specified and directed |
| 52 | M&L for preparation of new plastered or unplastered surface and applyingthree coats of white wash on wall complete and all as specified and directed. |
| 53 | M&L for preparation of new plastered surface and applying two coats of white wash on ceiling surfaces complete all as specified and directed |
| 54 | S&F in repair Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 55 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm each complete all as specified and directed |
| 56 | S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) frame (shutter type)for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed |
| 57 | S&F for powder coated aluminium doors , (thickness of powder coating not less than 50 micron) alumonium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handels 2 Nos in each door, anodised aluminium snap beading screws etc. complete all aspecified and directed |
| 58 | S&F in repair for powder coated anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer |
| 59 | S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.omplete all as specified and directed |
| 60 | Supply and fix sheet glass 5.5 mm thick of selected quality (tinted glass) exc. 0.5 sqm each fixed to aluminium frame work with necessary rubberbeading complete all as specified and directed by Engineer in Charge,. |
| 61 | S&F for 100mm long butt hinges medium weight, mild steel, and fixedcomplete all as specified and directed |
| 62 | S&Faluminium body mortice lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.Make : Godrej/Harison |
| 63 | S&F for 125mm long aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed |
| 64 | S&F for 125mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 65 | S&F for 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete and specified and as directed |
| 66 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqmand notn.exc 2.5 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge. |
| 67 | Supply and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Windowprofile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Doortransmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing withselected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 68 | Supply and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) |
| 69 | Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete,such as switches, ceiling roses,pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge. |
| 70 | M&L for concealed point wiring with single corePVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC conduit, medium grade, ISI markednot less than 20mm dia, with all fittings including Tee, Junction boxes and provision of Modular Metal flush boxand White plate with frame of suitable module for mounting switch sockets and regulators and drawing continuous earth wire ofPVC insulated unsheathed 1100 Volts grade cable withstrandedcopper conductor of size 1.5 Sq mm (Nominal area) for one light point controlled by one SP switch complete all as directed.Note :- (i) ModularMetal flush boxand White plate with frame of suitable module also included in the unit quoted rate of item. (ii)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for neutral and Green for earth.(iii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces.(iv) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided as directed.(v) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed |
| 71 | All as per item No 70 above butone fan/exhaust fan and wall mounted fan point controlled by one SP switch. |
| 72 | All as per item No 70 above but for one 3 pin socket out let, 6 Amps on Independent board |
| 73 | All as per item No 70 above but for one 3 pin socket out let, 6 Amps on same board |
| 74 | All as per item No 70 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wirerequired size all as specified and directed by Engineer-in-Charge. |
| 75 | S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed. |
| 76 | S & FModular Socket, 6A - 3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed . |
| 77 | S&FModular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed . |
| 78 | S & FModular Socket, 16A - 2/3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed. |
| 79 | Supply and fix electronic modularfan regulator rotary flush step type 120 watt, 240 volt complete complete all as specified and directed. . |
| 80 | Taking down Ceiling fan , cable end, dismantling blades and removing fan and blades to store |
| 81 | Supply & fix energy efficientBLDC ceiling fan 1200mm sweep , 28 Watt with remote , ISI mark with 5 star rating ,white colour, single phaseincluding all fixing arrangementhanging in roof likesuitable size of fan road clips , bolt , nut ,washers and 3 core flexiblecopper wire of size 1.5 sqmm not less than 0.5mtr longwith all accessoriescomplete all as specified and as directed. |
| 82 | Supply and fixing warm white LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifed and directed . |
| 83 | Taking down unserviceable submain wiring of alluminium two/three runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified andcomplete all as specified and directed by Engr-in-Charge. |
| 84 | M & L for submain wiring with two run of singlecore 10.0 sqmm PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 10.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified. Note : 2 Runs of 10.0Sqmm singlecoreand one run of 10.0 sqmm single core cable and one run PVC conduit measured as one unit. |
| 85 | M & L for submain wiring with two run of 6.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 6.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified. Note : 2 Runs of 6.0Sqmm singlecoreand one run of 6.0 sqmm single core cable and one run PVC conduit measured as one unit. |
| 86 | M & L for submain wiring with two run of 4.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 4.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified Note : 2 Runs of 4.0Sqmm singlecoreand one run of 4.0 sqmm single core cable and one run PVC conduit measured as one unit. |
| 87 | Supply and fixingin replacement load line vertical distribution boardmade out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for supply and fixing ofFPincomer MCCB of 160 Amps 25 KA complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately. |
| 88 | Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCAmild steel sheet surface mounting SPN8 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately. |
| 89 | Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 4 way 230 volts double door type horizontal type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately. |
| 90 | Supply and Sheet metal enclosure single pole and neutralwith two pin and earth plug and socket 20 Amps compete with oneSP MCB 20 Amps fixed flush in wall including cutting chases in wall for fixing DB and making good the disturbed wall surface to match with existing specification. |
| 91 | Taking down unserviceable SP/ SPN MCBs of any capacities from the MCB DBs after disconnecting the electric supply complete all as specified. |
| 92 | S&Fin replacement forMCB SPN 32 Amps 10 KA, 240 volt50 Hz \"C\" Series all as specified and directed by engineer-in-charge. |
| 93 | S&Fin replacement forMCB SPN 40 Amps 10 KA, 240 volt50 Hz \"C\" Series all as specified and directed by engineer-in-charge. |
| 94 | S&Fin replacement forMCB SP 6to 32 Amps 10 KA, 240 volt \"C\" Series all as specified and directed by engineer-in-charge. |
| 95 | Dismantling the outdoor unit of Split AC 1.5/2 TR and installation of the same after building repair at same location including gas charging at site to make AC functional att as spedified and directed. |
| 96 | S & F in replacement refrigerant line copper tube 1/2\"\" bore incl insulation of AC pipe complete all as specified and directed. |
| 97 | S & F in replacement refrigerant line copper tube 1/4\"\" bore incl insulation of AC pipe complete all as specified and directed. |
| 98 | Supply & Fixing in replacement of PVC pipe of size medium grade 25mm dia fixing on wall by using clamps and screwing including necessary tee, collar, bend, socket etc complete all as specified and directed. |
| 99 | Supply & Fixing in replacement of PVC pipe of size medium grade 40mm dia fixing on wall by using clamps and screwing including necessary tee, collar, bend, socket etc complete all as specified and directed. |
| 100 | Supply & Fixing in replacement of flesible thredded pipe from indoor unit to main line size of 15/20 mm dia, fixing on wall by using clamps and screwing compete all as spedified and directed. |
| 101 | M & Lfor making steel angular frame of size 16x16x3mm made of mild steel angle type for outdoor unit of the AC all as specified and directed. |
| 102 | M & L for 3 core 4 sqmm PVC insulated multistranded copper conductor cable 1100V grade complete all as specified and directed. |
| 103 | Supply,install test & commmissioning of high wall mounted inverter type split AC ,having indoor and outdoor units with copper tube evaporator & condensing unit of capacity 2 Ton capacity complete with cordless remote control unit and with minimum 5 star rated and EER 5.05 with necessary fixing arrangements,drain water piep upto required length ,stand for outdoor unit ,with 3 core PVC insulated and PVC sheathed copper cable of required sizecomplete all as specified and directed by Engineer in Charge. |
| 104 | Taking down ceiling fan for fixing/ installation of anti suicide road and refixing the same celing fan including electric connection with suitablesize cappoer cable etc complete all as specifed and directed. |
| 105 | Supply and fixing of anti suicide fan rod (12\") white MS pipe zinc plated, 19mm OD 1.8+/- 0.5mm thick, sprong set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 Kgf+ and spring \"hidden in the pipe will expand to about 1 mtr or more, complete as specified and directed by Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy