| 1 | Supply, install, commissioning & testing of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR or higher rating based on Inverter Technology comprising of variable speed copper compressor suitable for adjusting power depending on heat load incl indl indoor & outdoor units complete with cordless remote control unit & with in-built stabilizer free operation & PM 2.5 Filter etc. for better indoor air quality with 5 star rating incl electric connection complete all as specified and as directed. Make : BLUESTAR/DAIKIN/HITACHI/VOLTAS/CARRIER. |
| 2 | (i) Technical Specifications/particulars etc. of the Split ACs is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall be Non-CFC type & as per the latest technology.(iii) Unit Quoted rates shall be deemed to be inclusive of the following connected items/job/work etc. :(a) Cost of use/hiring/rent including transportation of Aluminum Tower Ladders/Scaffolding arrangements etc. required for successful execution of the complete work/Job. Subject work/job of fixing the Split ACs at a height of approx 8-10 mtrs above FFL incl fixing arrangement etc. is to be carried out to the entire satisfaction of the Engr-in-Charge/GE. Quoted rate is also deemed to be inclusiveof all safety precautions/measures to be taken by the contractor for labour employed at the site. (b) Cost of copper refrigerant pipes for suction and discharge lines for connection of indoor to outdoor units of 1.5 ton split AC of standard size as per OEM recommendation with proper insulation including fixing arrangement with appropriate size MS clamps and jointing of pipe with brazing etc including all necessary items required complete all as specified and directed by Engr-in-Charge.(c) Cost of 3 core weather proof copper cable minimum 4.0 sqmm, multistranded for electrical connection of Indoor & Outdoor Units. (d) Cost of PVC pipe 25mm dia high grade for ACs drain water suitable for outdoor mounting including connecting tees, bends, reducers etc. for leakage free jointing etc, including appropriate size PVC clamps and other required material for fixing on wall/cemented surfaces at heights as specified here in above complete all as specified and directed by Engineer-in-Charge.(e) Cost of making of holes to existing wall/wooden panelling etc. using core cutting machine of suitable dia for the run of copper refrigerant tubings, connecting cables etc. and making good the disturbed surfaces/false ceilings etc. complete all as directed by Engr-in-Charge.(f) Cost of MS angle iron frames of minimum size 50 mm x 50 mm x 6 mm suitable for fixing of Outdoor Units of Split AC\"s 1.5 Ton including fixing on wall/other surfaces etc. with necessary fixing arrangements like nuts, bolts, washers etc. as required on ground inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-charge. |
| 3 | (g) Cost of PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in platform/plinth for embedding/holding of MS angle iron frames as cited here in above for fixing of Outdoor Units of Split AC\"s 1.5 Ton incl necessary formwork & applying two coats of white wash to exposed surfaces complete all as specified and directed by Engr-in-charge.(h) Cost of perforated cable tray, made up of 2.0mm thick galvanized iron sheet, duly bend to required shape by sheet bending machine, including cover, made of 1.2mm thick plain galvanized iron sheet duly screwed with the cable tray and duly fixed on the wall/ceilings etc. including suitable galvanized iron brackets or hanging/suspended etc. from the ceiling with suitable suspenders as required at site complete all as specified and as directed by the Engineer -in Charge of minimum tray size 100 x 150 x 2 mm with cover of size 150 x 155 x 1.2 mm.(j) Cost of making good the disturbed surfaces incl matching to the existing/old surfaces.(k) Cost of neatly writing/marking MES Number on the body of Split AC Indoor Unit using stencil of size/dimensions complete all specified & as directed by the Engr-In-Charge. (iv) All the necessary OEM/Auth Supplier Test Certificates as per relevant IS/IEC incl the Guarantee/Warranty Certificates is to be submitted in Original to the Engr-In-Charge.(v) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.(vi) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. |
| 4 | Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 175 V to 250 V with Digital Voltmeter & O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 4.0 KVA suitable for 1.5 TR Inverter AC incl electric connection complete all as specified and as directed. Make : APLAB/VENER-7/SINETRAC or Techno-commercially equivalent makes as approved by HQ CE Commands. |
| 5 | (i) Technical Specifications/particulars etc. of the Voltage Stabilizer is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.(iii) All the necessary OEM/Auth Supplier Test Certificates as per relevant IS/IEC incl the Guarantee/Warranty Certificates is to be submitted in Original to the Engr-In-Charge. |
| 6 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five Star rated with Brushless Direct Current Motor (BLDC) complete all as specified and directed by Engr-in-Charge. Make : HAVELLS/BAJAJ/POLYCAB/CROMPTON/USHAImportant Notes :(i) Technical Specifications/particulars etc. of the BLDC Ceiling Fan is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) Unit Quoted rates shall be deemed to be inclusive of the following connected items/job/work etc. :(a) Cost of additional length of Ceiling Fan down rods matching with the original one upto lengths based on actual ground requirements for locations/rooms with false ceilings of any size/type incl making good the disturbed surfaces & matching to the existing/old surface complete all as specified & as directed by the Engr-In-Charge.(b) Cost of making electric connections incl provn of 15 mm dia grey coloured flexible hose pipe from ceiling rose to BLDC Ceiling Fans complete all as specified and directed by Engr-in-Charge.(c) Cost of neatly writing/marking MES Number on the body of Ceiling Fan using stencil of size/dimensions complete all specified & as directed by the Engr-In-Charge. |
| 7 | (i) Technical Specifications/particulars etc. of the BLDC Ceiling Fan is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) Unit Quoted rates shall be deemed to be inclusive of the following connected items/job/work etc. :(a) Cost of additional length of Ceiling Fan down rods matching with the original one upto lengths based on actual ground requirements for locations/rooms with false ceilings of any size/type incl making good the disturbed surfaces & matching to the existing/old surface complete all as specified & as directed by the Engr-In-Charge.(b) Cost of making electric connections incl provn of 15 mm dia grey coloured flexible hose pipe from ceiling rose to BLDC Ceiling Fans complete all as specified and directed by Engr-in-Charge.(c) Cost of neatly writing/marking MES Number on the body of Ceiling Fan using stencil of size/dimensions complete all specified & as directed by the Engr-In-Charge. |
| 8 | M & L for concealed sub-main wiring alongwith earth wire of size (4 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of minimum size 25 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE : 1) Four runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire. |
| 9 | M & L for sub-main wiring alongwith earth wire of size (2 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates.NOTE : 1) Two runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire. |
| 10 | S & F TPN DB, 4 Way, IP43, IK09, Metal double door type 415 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 11 | S&F MCB, TPN, C-Series 415 Volts of capacity 16-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. (1W+1S) Make-L&T/LEGRAND/SIEMENS/ABB. |
| 12 | S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 13 | S&F single pole & neutral sheet metal enclosure with a two pin & earth plug & socket complete with one single pole MCB, \"C\" Curve, 10 KA, 20A all as specified & as directed to the entire satisfaction of the Engr-In-Charge.NOTE for Item Nos 3 to 6 : Make of MCBs shall be same as the make of MCB DBs. |
| 14 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Make of GI Pipe : TATA/Jindal/PrakashNOTE : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. |
| 15 | M & L for laying earth continuity conductor or main earthing lead of 4 mm dia GI wire, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 16 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), fixed on Perimeter/Street light PCC poles etc. of bore 15 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| 17 | Supply, install, commissioning & testing of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR or higher rating based on Inverter Technology comprising of variable speed copper compressor suitable for adjusting power depending on heat load incl indl indoor & outdoor units complete with cordless remote control unit & with in-built stabilizer free operation, PM 2.5 Filter, Anti-dust Filter, Audjustable Mode, 4-way swing with & including the feature of \"SUPER DRY\" mode to facilitate humidity control etc. for better indoor air quality with 5 star rating incl electric connection complete all as specified and as directed. Make : BLUESTAR/DAIKIN/HITACHI/VOLTAS/CARRIER. |
| 18 | Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 175 V to 250 V with Digital Voltmeter & O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 4.0 KVA suitable for 1.5 TR Inverter AC incl electric connection complete all as specified and as directed. Make : APLAB/VENER-7/SINETRAC or Techno-commercially equivalent makes as approved by HQ CE Commands. |
| 19 | Supply, install, commissioning & testing of Programmable Microprocessor based Control Panel with Touch Screen Display HMI incl electric connection complete all as per existing model & specifications & perfectly suitable for Chiller Unit of Central Type AC Plant Water/Air Cooled of capacity 37 TR all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Suitable for Voltas/Bluestar AC Plant (as per OEM recommendation & site requirement).Important Notes for Item above :(i) Technical Specifications/particulars etc. of the Items is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.(iii) All the necessary OEM/Auth Supplier Test Certificates as per relevant IS/IEC incl the Guarantee/Warranty Certificates is to be submitted in Original to the Engr-In-Charge.(iv) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. |
| 20 | M&L for taking down Ceiling Fan of any size/make fixed/hanged at different locations & replacing conventional fan rod with Anti-Suicide fan rod and re-fixing the Ceiling Fan on the same/original position including making necessary electric connections & testing complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. NOTE : (i) Anti-Suicide Fan rod and rubber reel shall be measured & paid separately. (ii) Quoted rate is deemed to be inclusive of transportation/depositing of old /existing fan rod to MES Store Yard. (iii) Quoted rate is also deemed to be inclusive of fixing & testing of serviceable rubber reel & cleaning/dusting of C/Fan complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. |
| 21 | S&F Anti-Suicide fan down rod made up of MS size 300 mm (12\") white colour for ceiling fan of any size and any make as per manufacturer recommendation incl testing complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Gold Life or Techno-commercially equivalent Make. NOTE : Design/Drawing/Technical Specifications is to be submitted to the Engr-In-Charge for Make/Sample Approval before placing final order to the Manufacturer/Supplier. |
| 22 | S&F rubber reel insulator of suitable size for Ceiling Fan with necessary clamp, nuts, bolts & washers incl testing complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Sample to be Approved. |