| 1 | Taking down copper/aluminium point wiring ( light, fan, bell,socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc completeall as specified and as directed. |
| 2 | Material and labourfor surface point wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces completeall as specified and as directed. |
| 3 | Description allas per item No 2 abovebut 5 amps socket point independent |
| 4 | Description all as per item No 2 abovebut5 amps socket point on same board |
| 5 | Description all as per item No 2 abovebuttwo way light point controlled by two way switch |
| 6 | Description allas per item No 2 abovebutcable of size 2.5 sqmmfor one 16 amps socket (Power) point independent . |
| 7 | Material and labourfor point wiring with 1.5Sqmm multistrand PVC insulated unsheathedcopper conductor cable multystand FRLS 1100Voltandincluding PVC concealed conduit ISI marked, wall thickness 2mm medium duty for one light or fan/bell point controlled by one switch including 3mm thick laminated sheet using existing MS/CI sunken box including PVC green insulated 1.5Sqmm solid copper conductor cable contineous earth wire and connecting to earth dolly complete all as spd and as directed. |
| 8 | Material and labourfor point wiring with 1.5Sqmm multistrand PVC insulated unsheathed copper conductor cablemulty stand FRLS 1100 Voltand including PVC concealed conduit pipe ISI marked, medium duty for 2-in-one5Amp sswitch socketindependent including 3mm thick laminated sheet using existing MS/CI sunken box including PVC green insulated 1.5 Sqmm multistranded copper conductor cable contineous earth wire and connecting to earth dolly completeall as specified and as directed. |
| 9 | Material and labourfor point wiring with 4 Sqmm multistrand PVC insulated unsheathed copper conductor cablemulty stand FRLS 1100 Voltand including PVC concealed conduit pipe ISI marked, medium duty for 2-in-one15Amp sswitch socketindependent including 3mm thick laminated sheet using existing MS/CI sunken box including PVC green insulated 2.5 Sqmm multistranded copper conductor cable contineous earth wire and connecting to earth dolly completeall as specified and as directed. |
| 10 | Material and labourfor cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth.completeall as specified and as directed. |
| 11 | Material and labourfor surface submain wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduitsize with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dollyincl dismantling taking down old unserviceable wiring and making good to disturbed surfacescompleteall as specified and as directed.NOTE:- (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. |
| 12 | Description all as per item No 11 abovebutcable of size 2.5 sqmm complete. |
| 13 | Description allas per item No 11 abovebutcable of size 4.0 sqmm complete. |
| 14 | Description all as per item No 11 abovebut cable of size 6.0 sqmm complete. |
| 15 | Description allas per item No 11 abovebutcable of size 10.0 sqmm complete. |
| 16 | Supply and fix5 Amp switch piano type single pole one way incl dismantling taking down unsv one all completeall as specified and as directed. |
| 17 | Supply and fixbell push piano type one way 240 volt incl dismantling taking down unsv one completeall as specified and as directed. |
| 18 | Supply and fix5 Amp switch piano type single pole two way incl dismantling taking down unsv one completeall as specified and as directed. |
| 19 | Supply and fixsocket outlet flush type 6 amps, 5 pin, 230v incl dismantling taking down unsv onecompleteall as specified and as directed. |
| 20 | Supply and fixswitch socket combination multipurpose 2-in-1 flush type 6 amps, 230 v incl dismantling taking down unsv one completeall as specified and as directed. |
| 21 | Supply and fixswitch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismantling taking down unsv oneall as specified and as directed. |
| 22 | Supply and fix call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismantling taking down unsvall as specified and as directed. |
| 23 | Supply and fixlamp holder insulated body with back plate for batten fitting incl dismantling taking down unsvall as specified and as directed. |
| 24 | Supply and fix modular switch 1 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed .MAKE :- Legrand (myrius) cat part No-6730 00 or equivalent of Crabtree(Athena/, Havells(Oro)/ Anchor (Vision)/SSK |
| 25 | Supply and fix modular switch 2 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed.MAKE :- Legrand (myrius) cat part No-6730 01 or equivalent of Crabtree (Athena/, Havells(Oro)/ Anchor (Vision)/SSK |
| 26 | Supply and fix modular bell push, 5/6 Amps, 1/2 module (ISI marked) complete all as specified and as directed.MAKE : - Legrand (myrius) cat part No- 6730 19 or equivalent of Crabtree (Athena/, Havells(Oro)/ Anchor(Vision)/SSK |
| 27 | Supply and fix modular socket, 5/6 Amps, multi pin (ISI marked) complete all as specified and as directed.MAKE :- Legrand (myrius) cat part No- 6730 44 or equivalent of Crabtree (Athena/, Havells(Oro)/ Anchor(Vision) /SSK |
| 28 | Supply and fix modular switch 1 way, 16 Amps, 1 module (ISI marked) complete all as specified and as directed.MAKE :- Legrand (myrius) cat part No- 6730 08 or equivalent of Crabtree(Athena/, Havells(Oro)/ Anchor(Vision) /SSK |
| 29 | Supply and fix modular socket, 6/16 Amps, multi pin (ISI marked) complete all as specified and as directed.MAKE :- Legrand (myrius) cat part No- 6730 45 or equivalent of Crabtree(Athena/, Havells(Oro)/ Anchor(Vision)/SSK |
| 30 | Supply and fix modular typefan regulator 100W - 2 module complete all as specified and as directed.MAKE :- Legrand (myrius) cat part No- 6730 29 or equivalent of Crabtree(Athena/, Havells(Oro)/ Anchor(Vision)/SSK |
| 31 | Supply and fix 2 modular vesta combine plate regular white size 4.50 X 4.50 BS19104 complete all as specified and as directed. |
| 32 | Supply and fix 4 modular vesta combine plate regular white size 4.50 X 7.00 BS19102 complete all as specified and as directed. |
| 33 | Supply and fix 6 modular vesta combine plate regular white size 4.50 X 8.50 BS19105 complete all as specified and as directed. |
| 34 | Supply and fix 10 modular vesta combine plate regular white size 4.50 X 12.50 BS19107 complete all as specified and as directed. |
| 35 | Supply and fixceiling rose surface Bakelite three terminal incl dismantling taking down unsv oneall as specified and as directed. |
| 36 | Supply and fix flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismantling taking down unsv oneall as specified and as directed. |
| 37 | Supply and fixMCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv oneall as specified and as directed. |
| 38 | Supply and fixMCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv oneall as specified and as directed. |
| 39 | Supply and fixMCB,TP , 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv oneall as specified and as directed. |
| 40 | Supply and fixMCB, Four Pole, 40 to 63 amps, 415 Voltsincl dismantling taking down unsv oneall as specified and as directed. |
| 41 | Labour only for taking down old unsv DBs 4 way, 6 way &12 way of any size all as specified and as directed. |
| 42 | Supply and fixsheet metal enclosure DBs single door two way,all as specified and as directed. |
| 43 | Supply and fixMCB distribution board, double door, metal enclosure, SPN, 230 Volts, 4 way complete all as specified and as directed. |
| 44 | Supply and fixMCB distribution board, double door, metal enclosure, SPN, 230 Volts, 8 way complete all as specified and as directed. |
| 45 | Supply and fixMCB distribution board, double door, metal enclosure, SPN, 230 Volts,12 way all as specified and as directed. |
| 46 | Supply and fixvertical MCB distribution board, as MCB incomer, double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and as directed. |
| 47 | Supply and fixvertical MCB distribution board, as MCCB incomer, IP 43 protection, double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and as directed. |
| 48 | Supply and fixmetal plug and socket board with MCB SP 20 amp, 16 KA. all as specified and as directed. |
| 49 | Supply and fixhylam sheet 3mm thick on existing concealled MS/CI ractangular of size 300mmX200MM Square sheet incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc complete all as specified and as directed. |
| 50 | Supply and fixPVC rectangular switch board of size 300mmx 250mm x50mmincl necessary cutting slots for mounting switch sockets etc incl. completeall as specified and as directed. |
| 51 | Supply and fixPVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc. completeall as specified and as directed. |
| 52 | Supply and fixPVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc.all as specified and directed. |
| 53 | Supply and fixPVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc. all as specified and directed. |
| 54 | Supply and fixLEDtube rod retrofit 20 wattretrofitPF 0.9 to replace existing fluorescent tube rod surface mounted and complete rewiring with 0.5 sqmm copper flexible conductor, connecting up to ceiling rose completeall as specified and as directed. |
| 55 | Supply and fix industrial box type LEDbase with prewired suitable for single LED rod 20 watt 4\"long. base/fitting any type all as specified and as directed. MAKE :- CG Cat Part No.-I GP1611LT8-16 Or techno commercialEquivalent in wipro/philips/Havells. |
| 56 | Supply and fix LED batten fitting \" 2\"long, 10 watt,CDL230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos. any type all as specified and asdirected.MAKE :- CG Cat Part No- CCS-102-10- 40 -SL-HL2-DP-NWH or Techno commercial equivalemt in wipro/philips/Havells. |
| 57 | Supply and fixLED tube light batten fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos fitting any type all as specified and as directed. MAKE :- CG Cat Part No CCS-102- 20- 40 - SL-DP-NWH or equivalemt in wipro/philips/Havells. |
| 58 | Supply and fixLED building security light 30 watt, 230V with lens and toughen glass top complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, one GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener. all as specified and as directed. MAKE :- WIPRO Cat Part No LRO2-331-XXX-57-XX. or Techno commertial equivalent in wipro/philips/Havells. |
| 59 | Supply and fixPDC housingLED Bulk headlightenergy efficient with opal diffuser, equiped with 2 KVin built surge protection withIP65 protection wall mounted LED 10 watt, 230 V complete with all accessories,connecting up to ceiling rose/connector with 0.5 sqmm two core copper flexible conductor cableall as specified and as directed. MAKE :- WIPRO CP No. SZSBHMXo10. or equivalent in philips/CG/Surya. |
| 60 | Supply and fix in replacement ofLEDpost top lantern 20 watt complete with 40/50 mm GI Pipe Light grade, clamps, nut, bolt and washers, incl1.5 sqmm two core copper flexible conductor cableall as specified and as directed. MAKE :- WIPRO Cat part NoLP07-251-XXX-57-CL. or equivalent in wipro/philips/Havells. |
| 61 | Supply and fix LED fitting the soft round shapes and use of metal and glass create a timeless look that resembles lamps of the pastaesthetically designedfrosted glass with chrome finishwall lampwith B27 LED 7 Watt lamp. MAKE :- JaguarCat Part No JNL-CHR-MB160275542A or equivalent in wipro/philips/Havells. |
| 62 | Supply and fixLED driver of 15 to 30watt suitable for BuildingLED security light completeall as specified and as directed. |
| 63 | Taking down and servicing of ceiling fan1200/1400 mm sweep and exhaust fan 250/300mm sweep at site of each qty and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, and re-assembling the fan and exhaust fan complete all as specified and as directed. |
| 64 | REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :-Material and labour for rewinding of ceiling fan 1200/1400 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete all as specified and as directed. NOTE :- 1. Contractor will collect fans from the complaint cell of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as Supply and fixing only. |
| 65 | Description all as per item No- 64 above but for exhaust fan 250/300 mm sweep industrial type. |
| 66 | Supply only ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC. |
| 67 | Supply only G.M. bush bearing for ceiling fan as per existing pattern. |
| 68 | Supply only capacitor AC for 230 volts 50 Hz of capacity 1/1.5 Mfd. |
| 69 | Supply only capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd. |
| 70 | Supply only capacitor AC for 230 volts 50 Hz of capacity 3.15/4.0 Mfd. |
| 71 | Supply only canopy for ceiling fan as per specified and directed |
| 72 | Supply only metal ceiling fan clamp all as specified and directed |
| 73 | Supply only down rod for ceiling fan as per existing lenght 300mm to 600mm all as per specified and as directed. |
| 74 | Supply only blade for 1200/1400 ceiling fan any type |
| 75 | Material and labour for painting of ceiling fan 1200/1400 mmincluding scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by Engr-in-Chage. |
| 76 | Supply and fixPVC insulated PVC sheathed copper flexiable wire multistrand 1.5 sqmm 3 core, ISI marked completeall as specified and as directed. |
| 77 | Taking down carefully storage type water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc prefixing the same in position by replacingreconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioningcomplete all as specified and asdirected. for geyser of capacity 25 liters capacityNOTE :-Non return valve stop cock, PVC/Copper connections cable, thermostat etc shall be measured separately. |
| 78 | Description all as item No. 77 abovebut50 liters capacity complete |
| 79 | Supply only heating element of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elementscomplete all as specified and asdirected. |
| 80 | (a)1.5 Kilo Watt Capacity |
| 81 | (b) 2.0 Kilo watt capacity |
| 82 | Supply onlythermostatrectangle/hexagonal suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable onescomplete all as specified and asdirected. |
| 83 | Supplyonlyvertical/ horizontal non return valve (gun metal) of following sizes.:- |
| 84 | (a)Suitable to 15mm bore |
| 85 | (b) Suitable to 20mm bore |
| 86 | Supply and fixin repair inner water containermade of SS,vertical or horizontal type for 25/50 ltr capacity gysercomplete all as specified and asdirected. |
| 87 | Supply and fixin repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap complete all as specified and asdirected. |
| 88 | Supply and fixin repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450 mm long for cold water all as specified and directed. |
| 89 | Supply and fixin repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450 mm long for hot water all as specified and directed. |
| 90 | Supply and fixMCB distribution board, double door, metal enclosure for fixing ofRCCB 2 Pole 10 Amp. 230 Volts, 2 way incl dismantling taking down unsv onecomplete all as specified and asdirected. |
| 91 | Material and labourRCCB 2 pole 30mA10 Amp 10KA ISI/CE marked as per IS/IEC degree of protection IP20 rated conditional short circuit current, Icc 10KA 50 Hz operating voltage 240ACcomplete all as specified and asdirected. |
| 92 | Supply and fix and replacementmeter panel floor/mounted on wall, cubicaltype, compartmentalized dust and vemin proof, indoor installation IP 42 type electrical control panel, includingPVC channel 25x45 mm, made out of powder coated CRCA sheet of size 700x700x200 mm (thickness 1.6mm)having an arrangement of fixing the energy meter single phase five number inside the panel and having glasss door to take meter readingwithout open the panel with an arrangement of incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulatedunsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable sizw of lugs/thimblewith locking arragement & one lock including dismentling and taking down old unserviceable meter wooden board and making good to disturbed suffces complete all as specified and as directed. MAKE :- Krutika electricals or quivalent as approved by GE, The Panel shall comprise the following items ;(a) 63 Amp MCCB,4 Pole -01 (incoming)(b) 32 Amp MCB, DP - 05 (outgoing) (c)Spreader Link(d)Busbar and cable outgoing (e)Shunt coil(f) suitable Space for fixing 5 energy meterNote : Rate quoted by contractor shall be inclusiveof takind down and refixing the existing meter. |
| 93 | Description allas per item No 87 here-in-beforebutwith following itemscomplete all as specified and directed. (a) 63 Amp MCCB,4 Pole -01 (incoming)(b) 32 Amp MCB, DP - 04 (outgoing) (c)Spreader Link(d)Busbar and cable outgoing (e)Shunt coil(f) suitable Space for fixing 4 energy meterNOTE :- Rate quoted by contractor shall be inclusiveof takind down and refixing the existing meter. |
| 94 | Material and labourfor Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr belo ground level connected to galvanized iron strip of size 25x6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earh work GI pipe 20 mm dia medium grade for watering PCC chamber with PCC cover in cement concreate 1:2:4 Type B1 (20 mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc connected to panel board/ Gen set as indicated including testing complete all as specified and as directed. NOTE :- Earth protection pipe & earthing strip upto and including 7.5 m lenth is deemed included in unit rate quoted by the contractor. |
| 95 | Material and labourEarthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion all as specified and directed. |