| 1 | Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses,pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition seperately)andmaking good disturbed surface of walls, floors etc all as per the existing finish complete all as specified and as directed. |
| 2 | Material and labourforpoint wiring for light / fan / exhaust/bell point in casing andcaping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall complete all as specified and as directed. |
| 3 | Description allas per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 4 | Description all as per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 5 | Description all as per Srl item No 2 above butfor 2.5 sqmm point wiring for 5 pin switch socket outlet 15 Amps onindependent board controlled by one switch. |
| 6 | Material and labourforpoint wiring for light/fan/exhaust inPVC conduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall complete all as specified and as directed. |
| 7 | Description all as per Srl item No 6 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 8 | Description all as per Srl item No 6 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 9 | Description allas per Srl item No 6 above but for for one 6 pin switch socket outlet 15 Amps Point on independent board controlled by one switch in PVC conduit. |
| 10 | Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arragements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mmon surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wireincl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc.and making good the disturbed wall and painting the same with matching colour of the existing wall, incld material complete all as specified and as directed. |
| 11 | Description allas per Srl item No 10 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 12 | Description allas per Srl item No 10 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 13 | Material and labour for point wiring completeas specified with 1100 V grade4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FR grade, conforming to relevant IS drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover including 4 Sqmm single core PVC insulated and unsheathed copper conductor cable FR grade as earth continuity wire connected to common earthand earth dolly including testing complete all as specified and as directed.for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch. |
| 14 | Description allas per Srl item No 13 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in steel conduit. |
| 15 | Description all as per Srl item No 13 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit. |
| 16 | Supply and fix switch piano flush type single pole, one way 5 Amp. |
| 17 | Supplying andfixingswitch flush type, 5 Amps,Bell push , flush type , 230 volts AC circuitcomplete all as specified and as directed. |
| 18 | Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal complete all as specified and as directed. |
| 19 | Supply and fix switch socket combination 2 in 1, 3 pin, 5 and15 Amp flush type universal complete all as specified and as directed. |
| 20 | Supplying andfixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed. |
| 21 | Supply and fixing in replacement Stepped type electronic fan regulator flush typesuitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and as directed. |
| 22 | Supply and fixbell ding dong AC, 230 volts, single pole complete all as specified and as directed. |
| 23 | Dismantling and taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any size and core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material complete all as specified and as directed. |
| 24 | Material andlabour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm PVC conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc.complete all as specified and as directed. |
| 25 | Description allas per Srl item No 24 above but for casing andcapping |
| 26 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVCconduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable,FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and as directed. |
| 27 | Description all as per Srl item No 26 above but for casing andcapping |
| 28 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and includingincluding New PVCconduit 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable,FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and as directed. |
| 29 | Description all as per Srl item No 28 above but for casing andcapping |
| 30 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type,10.0 Sqmm, 1100 volts grade, drawn through and includingincluding New PVCconduit 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable,FRLSH type,10.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and as directed. |
| 31 | Description allas per Srl item No 30 above but for casing andcapping |
| 32 | Disconnecting and taking down olddistribution box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and as directed. |
| 33 | Supply and fix, connecting andtesting of VTPN DB of 12 way suitable for MCCBup to 160A as a incomer andSP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties, complete all as specified and as directed.NOTE :- MCCB , MCBwill be measured and paid separately under relevant item of this schedule. |
| 34 | Supply and fix, connecting andtesting of VTPN DB of 8 way suitable for MCCBup to 160A as a incomer andSP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties, complete all as specified and as directed. NOTE :- MCCB , MCBwill be measured and paid separately under relevant item of this schedule. |
| 35 | Supply and fix, connecting andtesting of VTPN DB of 4 way suitable for MCCBup to 160A as a incomer andSP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties, complete all as specified and as directed.NOTE :- MCCB , MCBwill be measured and paid separately under relevant item of this schedule. |
| 36 | Supply and fix, connecting andtesting SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties, complete all as specified and as directed. MAKE :- LegrandCat.No. 5076 11 orequivalent in Schneider/Land T. |
| 37 | Supply and fix, connecting andtesting SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties, complete all as specified and as directed. |
| 38 | Supply and fix, connecting andtesting SPN DBs of 4 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 andmade of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar andwire ties,complete all as specified and as directed. |
| 39 | Supply and fix, thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 16 KA andshall be Ics=Icu 100%, complete all as specified and as directed. |
| 40 | Supply and fix, thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 16 KA andshall be Ics=Icu 100%, complete all as specified and as directed. |
| 41 | Supply and fix, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 16 KA andshall be Ics=Icu 100%, complete all as specified and as directed. |
| 42 | Supplying andfixing MCB 40 to 63Amps, TPN\"C\" curve10 kA breaking capacity with integrated label holder,sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 43 | Supplying andfixing MCB 6 to 32 Amps, single pole and neutral, \"C\" curve10 kA breaking capacity with integrated label holder,sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 44 | Supplying andfixingMCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly,complete all as specified and as directed. |
| 45 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug andsocket with sheet metal enclosure of IP44 ratingelectric driven single phase including MCB \"C\" series SP 20 Amps and supplied with neutral links complete all as specified and as directed. |
| 46 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug andsocket with sheet metal enclosure of IP44 rating electric driven three phase including MCB \"C\" series TP 20 Amps and supplied with neutral links complete all as specified and as directed. |
| 47 | Dismantling and taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories complete all as specified and as directed. |
| 48 | Supply andfixing, LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceiling complete all as specified and as directed. |
| 49 | Supply andfixing, CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod andconnecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceiling complete all as specified and as directed. |
| 50 | Supply andfixing, LED Inverter Batten suitable for and including 20 W 4 feet long tube with back up time of 3 hrs complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceiling complete all as specified and as directed. |
| 51 | Supply andfixing, 36W 2X2 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 52 | Supply andfixing, 36W 2X2 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 53 | Supply andfixing, 18W 1X1 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 54 | Supply andfixing, 18W 1X1 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 55 | Supply andfixing, 12WLED Round recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 56 | Supply andfixing, 40W,1ft x 4 ft LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 57 | Supply andfixing, 1X16W, 4 ft LED Flame proof light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 58 | Supply andfixing, 1X18W,4 Feet LED Ceiling suspended light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size andall accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 59 | Supply andfixing, 20W Single End LED Tube rod including connecting up in existing fitting andmake batten functional complete with all accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 60 | Supply andfixing, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting andmake batten functional complete with all accessories for fixing on steel trusses / false / normal ceilingcomplete all as specified and as directed. |
| 61 | Supply and fixing lamp holder, PVC/Polycarbonate type with black plate suitable for batten fittings etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and testingcomplete all as specified and as directed. |
| 62 | Material and labouropening the body cover of ceilingfan of sweep 1200/1400 mm of any make and cutting the existingworn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and backing complete including thesoldering new lead of copper wire testing complete including transportation to work shop and backcomplete all as specified and as directed.NOTE :- a) Contractor have to make the arrangement for testing of Rewinded fan upto 24hrs at Complaint cell of AGE E/M-II (C) Kirkee andin case of failure to above said testing apenalty of Rs 200/- per fan is deducted from contractors dueand rewinding of same once again is bonded.b) Fan should be return to MES yard after rewinding within 10 day from the date of issue otherwise a penalty of RS 10/- per day per fan is deducted from contractor due. |
| 63 | Description all as per item no 62 but forExhaust fan Upto 300 to 450mm sweep |
| 64 | Material and labourflexible wire of size 23/0.0076 for ceiling fan connection including taking down the old unserviceable wire complete all as specified and as directed. |
| 65 | Material and labourfor preparation of old painted surface of ceiling fan and applying one coat of synthetic enamel paint with spraying paint on machine including making MES number on body of the fan including taking down and refixing and connection and testingcomplete all as specified and as directed. |
| 66 | Supply and fix in replacement fan capacitor 2.5 mfd 240 V AC supply complete all as specified and as directed. |
| 67 | Supply and fix insulated enclosure 2 pole suitable for SPN MCB including taking out old one. complete all as specified and as directed.NOTE :- MCB shall be measured and paid separately. |
| 68 | Taking down carefully storage type water heater (Geyser) of size 25/50 litre after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by weilding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying oout testing for proper functioningcomplete all as specified and as directed. NOTE :-Non return valve stop cock, PVC/Copper connections cable glass wood thermostat etc shall be measured separately. |
| 69 | Supply and replace heating element of size 1.5/2.0 KWcapacity storage type water heater sof compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elementscomplete all as specified and as directed. |
| 70 | Supply andfix thermostat suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable onescomplete all as specified and as directed. |
| 71 | Supply and fix fusible plug suitable for 25/50 litre capacity storage type water heater including provn of necessary GI fittings removal of existingvalvescomplete all as specified and as directed. |
| 72 | Supply and fix modular switch one way 6 Amp 1 module complete all as specified and as directed. |
| 73 | Supply and fix modular white cover plate with frame ,3 module complete all as specified and as directed. |
| 74 | Supply and fix modular white cover plate with frame ,6 module complete all as specified and as directed. |
| 75 | Supply and fix modular white cover plate with frame, 8 module complete all as specified and as directed. |
| 76 | Supply and fix metal flush box 3 module. complete all as specified and as directed. |
| 77 | Supply and fix metal flush box 6 module. complete all as specified and as directed. |
| 78 | Supply and fix metal flush box 8 module complete all as specified and as directed. |
| 79 | Supply and fix modular switch one way 16 Amp 1 module complete all as specified and as directed. |
| 80 | Supply and fix modular socket , 6 A -2/3 pin combined 2 module complete all as specified and as directed. |
| 81 | Supply and fix modular socket , 15 A -2/3 pin combined 2 module complete all as specified and as directed. |
| 82 | Supply and fix modular fan step regulator 120 W-2 modulecomplete all as specified and as directed. |
| 83 | Supply and fix sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps, 240 Volts complete all as specified and as directed. |
| 84 | Supply and fix ceiling fan of 1200 mm sweep high speed, rust free coated powder finish including provision of cable from ceiling rose or connector to fan,anchor bolt for fixing of ceiling fan,ceiling fan rod at any heightcomplete all as specified and as directed. |
| 85 | Supply and fix exhaust fan (Plastic body)AC single phase 230/240 V of size 250/300 mm sweep with louvres and provn of flexible copper cord from ceiling rose to fan including making hole in wall without making disturbed the good surface complete all as specified and as directed. |
| 86 | Supply and fix Wall mounted fan 400mm sweep 230V, AC, SP oscilating swing type with all acceessories and fixing arrengementcomplete all as specified and as directed. |
| 87 | Material and labourfor taking out the unserviceable Meter Panel board including all connection and supply,installation, commissioning and testing of meter panel, intdoor typewall mounted base frame mounted dust proof with bus bar chamber to accommodate 3phase, 415Volt with suitable aluminium busbar designed as per relevant IS connectedto busbar by aluminium strip of suitable Size, fabricated out of 2 mm thick CRCA sheet for outer chamber and 1.6 mm thick for partition and doors and painting with seven tank process with twin shutter closing andlocking arrangements complete for provision of a) Incomig- MCCB 4Pole 100Amps-01 No , outgoing- , b) MCB DP 40A to 63 A-4 Nosc) MCB 6-32 A -01 Nos for building lightd) Ammeter-1 No,Voltmeter-01 No, CTs-1 Set, Indication lamp-1 Set of 3)provision for fixing energy meter 04 Nos, with wiring 6 sqmm power wire FRLSH and control wiring with suitable size and fixing the glass to take the meter readingcomplete all as specified and as directed. |
| 88 | Material and labourfor earthing complete with 17.2 mm having copper bonding thickness will be minimum 250 microns and copper bonded terminal size 130x50x5 mm terminalto connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.5 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolts and connected to test pointfrom earthing pit. Area between pipe and copper rod filled with Dry type chemical powder.The electrode pipes should be filled with 2x 25 kg bags of carbide based BFC earthing compound of product code BFC25SILVR. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between 7-9. Connected to the earthing test point, Special high grade polymer compound Round earth pitwith pit cover,including necessary returning fillingandremoval of extra soil , to achieved earth resistance valueless than 1 Omsincluding testing complete all as specified and as directed. NOTE :- IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost. |