| 1 | Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum, getting out , returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed |
| 2 | Surface excavation not exceeding 30cm deep averaging 15cm deep and getting out in soft /loose soil.complete all as specified and directed |
| 3 | M&L 100mm thick PCC type D-2 1:4:8 (40mm graded crushed stone aggregate) for sub base complete all as specified and directed |
| 4 | M&L for cement concrete 1:3:6 type C-2 using 40mm gradedcrushed stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed |
| 5 | M&L for brickwork with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specified and directed |
| 6 | M&L for PCC type B0 1:2:4(using 12.5mm graded crushed stoneaggregate) as in coping including use and waste of form work complete all as specified and directed |
| 7 | M&L for 15mm thick rendering in CM 1:4 with on fair surfaces of walls finished even & smooth without using extra cement complete all as specified and directed |
| 8 | M&L steel work conforming to Fe 410-0 or Fe 310-0 in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.complete all as specified and directed by Engr-in-Charge |
| 9 | S&F Mild steelround bars 6mm to 8 mm dia as in chain link fencing,cut to lentha and bent to shape required complete all as specified and directed. |
| 10 | Supply only MS galvanised chain link fencing, any size or shape as per sample approved by GE complete all as specified and directed |
| 11 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of GI clips/scruing clips complete all as specified and directed |
| 12 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square not exc 5 cm long dia of neck 11 to 15 mm complete all as specified and directed. |
| 13 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of new or previously un treated surfaces of any description and at any position complete all as specified and directed |
| 14 | M&L for preparation of newly plastered surfaces of wall & applying two coat of cement base paint of approved shade/tint after applying a coat of Birla care putty c2 kg/sqm complete all as specified and directed |
| 15 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (Base metal thickness) of an colour having tensile strength of 550 MPA as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 16 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 MPA thick(Base metal thickness) of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |