| 1 | S & F 5 KLD STP alongwithPMF Bed ( Above Ground Level) 3 x2 x1.2: Filter Feed Tank (UG Tank) 1.6 x 1.1 x 1.5(SWD): Treated Water Tank(UG Tank) 1.6x 1.1x 1.5 (SWD) complete all as specified and directed. |
| 2 | S & F 45 KLD STP alongwithPMF Bed ( Above Ground Level) 8.5 x 4.2 x 1.2: Filter Feed Tank (UG Tank) 2.7 x 1.4 x 1.5 (SWD): Treated Water Tank(UG Tank) 2.7X 1.4x 1.5 (SWD)complete all as specified and directed. |
| 3 | S & F 75 KLD STP alongwith PMF Bed ( Above Ground Level) 11x 5.5X 1.2: Filter Feed Tank (UG Tank) 3.4x 1.7x 1.5 (SWD): Treated Water Tank(UG Tank) 3.4x 1.7x 1.5 (SWD) complete all as specified and directed. |
| 4 | Site clearance in soft/loose soil complete all as specified and as directed. |
| 5 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 6 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 7 | Excavating over areas, exc 1.5 m deep but n.exc 3.00 and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Exavating in trenches n exc 1.5m wide & n exc 1.5m in depth for foundation etc or for shafts wells, cesspits, manholes piers holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and geeting out of soft/loose soil complete all as specified and as directed. |
| 9 | Exavating in trenches n exc 1.5m wide & n exc 1.5m in depth for foundation etc or for shafts wells, cesspits, manholes piers holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and geeting out of soft/disintigrated rock complete all as specified and as directed. |
| 10 | M&L for plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregateinfoundations, filling and mass concrete complete all as specified and as directed. |
| 11 | M&L for plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregateinfoundations, filling and mass concrete complete all as specified and as directed. |
| 12 | M&L for plain cement concrete 1:2:4, type B2 using 20mm graded stone aggregatein lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 13 | M&L for reinforcement cement concrete M-25 (20mm graded stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 14 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 15 | M&L for reinforcement cement concrete M-25 (20mm graded stone aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished complete all as specified and directed. |
| 17 | M & L for reinforcement cement concrete M-25 (20mm graded stone aggregate) as in beam bressumers, cantilevers, lintels over 1.50m span complete all as specified and directed. |
| 18 | M&L for formworkto sides and soffits of floor or roof beam, beam haunchings, girder, bressummers, lintels, cantilevers,shelves inculding supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed. |
| 19 | M & L for reinforcement cement concrete M-25 (20mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and like any thickness above top of footing inculding attached pilasters and buttresses complete all as specified and directed. |
| 20 | M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railingsand similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and as directed. |
| 21 | M&L TMTbars 10mmdia and over, cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends andbinding with and including mild steel wire (Annealed) notless than 0.9 mm dia all as specified and directed |
| 22 | M&L TMTbars8mm dia, cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends andbinding with and including mild steel wire (Annealed) notless than 0.9 mm dia all as specifed and directed. |
| 23 | M & L pre-cast cement concrete block masonry typeC-1 (1:3:6, using 20mm graded aggt) with solid blocks exc 10cm in width and setting in cement mortar 1:4 all as specified complete all as directed. |
| 24 | M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even & smooth without using extra cement complete all as specified. |
| 25 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 26 | S&F 75 mm bore PVC (SWR) pipes single socket in any lengthwith rubber ring laid in trenches or in floor complete all as specified and directed. |
| 27 | S & F 75mm PVC (SWR) vent cowl complete all as specified and as directed. |
| 28 | S&F 110 mm PVC (SWR) pipes (ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 29 | Returning, filling in, including spreading, levelling, watering and wellramming in layers not exc 25 cm. in soft/loose soil complete all as specified and as directed. |
| 30 | Returning, filling in, including spreading, levelling, watering and wellramming in layers not exc 25 cm. in soft/disintigrated rock complete all as specified and as directed. |
| 31 | Removing Excavated materials (soil) to a distance n. exceeding 50 m and deposting where directed at a level n. exc. 1.50m above the starting point, complete all as specifed and directed. |
| 32 | Removing Excavated materials to a distance exceeding 250 m a but n exc 500 m and deposting where directed at a level n. exc. 1.50m above the starting point, complete all as specifed and directed. |
| 33 | S & F 160 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc completeall as specified and directed. |
| 34 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 160 mm bore drain pipes complete all as specified and directed . |
| 35 | Supply , laying, jointing, testing & commissioning cross linked polyethylene ((XLPE) insulated cable for working voltage of 1100 Volts, PVC sheathed, armoured, 4.0 core nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I): 1998 including cable gland, lugs etc to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipes laid under floor/road, through concealed GI pipe along the wall etc complete all as specified and as directed. |
| 36 | Supply , laying, jointing, testing & commissioning cross linked polyethylene ((XLPE) insulated cable for working voltage of 1100 Volts, PVC sheathed, armoured, 2.0 core nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I): 1998 including cable gland, lugs etc to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipes laid under floor/road, through concealed GI pipe along the wall etc complete all as specified and as directed. |
| 37 | Supply, installation, testing and commissioning factory made LT cubical type panel board, CPRI approved, Outdoor type made out of 3.15mm CRCA sheet, power coated, dust proof, vermin proof (IP 54), weather proof with front operated double door type with separate hinge door for each compartment with locking arrangement, totally enclosed, mounted on PCC 1:2:4, type B-1 foundation of suitable size including grouting of panel with necessary excavation & earth work, etc. complete all as specified.The scope of work includesthe following accessories:-(i) Copper bus bar 4 strip, 100 Amps, 415 Volts- 01 Set(ii) MCCB, TPN, 32 Amps 10 KA, 415 volts - 01 No. (iii) MCCB, TPN, 20 Amps 10 KA, 415 volts - 01 No. (iv) MCB, SPN, 6-32 Amps 10 KA, 220 volts - 02 No. (v) Digital Multifunctional meter-01 No.(vi) Indicating lamp LED type one set in incoming phases - 01 No.(vii) Astronomical time switch control MCB and connected items to control security light for auto ON/OFF complete.NOTE:-(i) External terminals with tinned copper has to be provided for trmming the incoming & outgoing cables with suitable lugs of MCB (if required). |
| 38 | Supply and fix steel tubular swaged poles type 410-SP-22(8.5 meter long) Swan Neck Type complete with CI base plate and finialand single swan neck,complete all as specified and as directed. |
| 39 | Supply and fix LED street light 35 Watt, 230 Volts, AC outdoor type,with high pressure die cast aluminium hosting and heat rrsistant complete with driver, lamp bracket with impact and corrosion resiatant including thermal management in multiple opticals with IP 65/66 protection complete all as specified and as directed. |
| 40 | S&F street light bracket arm of length not less than 1.2m made out of 32mm bore light grade GI tube fixed to pole with 02 Nos suitable size flat iron clamp 40 x 5mm with nuts & bolts, washers etc including two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 41 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 42 | S&F Sub-Class B Brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 43 | S&F 1.50 Sqmm 3 core single phase copper conductor multistranded FRLS cable PVC insulated screened, PVC bedded, un-armoured, electric power cable 1100 Volts grade with stranded copper conductor for streel light/building security light fittings through existing pole/new pole/ pole to junction box/LT over head line to light fittings etc complete all as specified and as directed. |
| 44 | M&L for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 2.50m length, buried directly and perfectly vertically in ground with top edge not less than 1.25m below ground level connected with earth lead of 32 x 6mm galvanised iron or steel earth strip connected to eart test point complete all as shown in Plate No 2 SSRPart-I. |
| 45 | M & L for 40mm dia GI tube light grade with all fittings laid in floor/trenches /road crossings/drain etc as cable protection complete all as specified and directed. |
| 46 | S&F IP 65 protection junction box made of impact resistance polycarbonate & heat resistance materials of size not less than 155 x 210 x 92mm with terminals, dust Proof, water tight, light weight, weather proof, acid resistance, corrosion proof insulated and shock proof, Fire Retradrant,Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steself extinguishing, helogen & silica free non toxic materials, UV resistance with internal embedded gasket and fitted with required terminals alongwith type test certificate and verified by glow-wire test in accordance with IEC60695-2-11 complete all as specified and as directed. |