| 1 | Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc upto 6.00 mtr height complete all as specified and directed. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including taking down of backing plaster to brick / concrete wall surface), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but n.exc 4.0 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc Including brick work of jambs and Cillin CM 1:4 complete all as specified and directed. |
| 4 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc Including brick work of jambs and Cill in CM 1:4 complete all as specified and directed. |
| 5 | Dismantling wrought iron / Mild Steel work of any description not otherwise provided for complete all as specified and directed. |
| 6 | Dismantling of cast iron / PVC / AC / SGSW pipes alongwith fittings and accessories upto 100 mm dia jointed in cement mortar and taking out of walls, floors or trenches, if required complete all as specified and directed. |
| 7 | Dismantling of water tankscapacity exc 250 ltrs and n.exc 500 ltrs and removing to store complete all as specified and directed. |
| 8 | M & L Non skid coloured ceramicjoint less tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer of cement (1:6) complete. |
| 9 | M&L Glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM (1:4) on brick work concrete surface on wall and finished the even and fair to receive tiles complete all as spfd and directed. |
| 10 | M & L for 15mm thick rendering in cement mortar 1:6 on brick masonary wall surfaces onfair faces of brick masonaryfinishedeven and fair without using extra cement complete all as specified and directed. |
| 11 | M & L for 15mm thick rendering in cement mortar 1:4 on brick masonary wall surfaces or on other than fair faces of brick masonaryfinishedeven and fair without using extra cement complete all as specified and directed. |
| 12 | M & L for rendering 5 mm thick in CM 1:3 as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | M & L for preparation of new plastered surfaces of walls and applying two coat of oil bond distemper white or any tint over a coat of chalk whitening complete over prepared surface complete as specified and directed. |
| 14 | M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 15 | M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete. |
| 16 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.but both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges complete all as specified and directed. |
| 17 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing but single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and directed. |
| 18 | S&F of Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed. |
| 19 | S & F 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed. |
| 20 | S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or stainless wire staples,wodden beads to steel windows/wodden doors. |
| 21 | S&F Aluminium anodised barrel tower bolts of extruded section of 200mm size etc complete all as specified and directed. |
| 22 | S&F Aluminium handles, cast type anodised of size 100mm etc complete all as specified and directed. |
| 23 | S&F 250 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 24 | S & F 500 litre rotational moulded tripple layer polyethlene water storage tanks white colour (cylindrical vertical with closed top) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 25 | S & F 20 mm PTMT valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed |
| 26 | S & F as in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore complete all as specified and as directed |
| 27 | S & F in repair bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia pipe complete all as specified and as directed. |
| 28 | S & F in repair stop valves / angle valves fancy typechromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionsfixed for 15 mm dia bore pipe complete all as specified and as directed |
| 29 | S & F in repair PVC connection of 15mm size 450 mm length including brass nuts complete all as specifiedand as directed |
| 30 | S & F in repairs vitreous china squatting pan orissa pattern long pan size 580 mm x 440 mm white with spun pipe ‘P’ or ‘S’ trap including lead joint and CI spun branch piece , front or back inlet and foot rests excluding flushing cistern & flush pipe but incl. cement concrete bedding fixed complete all as specified and as directed. |
| 31 | S & F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed. |
| 32 | S&F 110mm bore PVC (SWR) P trap,including provision of PVC garting 110mm Size |
| 33 | S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls including fixing withclamps. |
| 34 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor 110 mm bore pipe with clamps |
| 35 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor 75 mm bore pipe with clamps |
| 36 | PVC (SWR) bends any radius for 110 mm bore pipe |
| 37 | PVC (SWR) bends any radius for 75 mm bore pipe |
| 38 | S&F 110mm bore PVC (SWR) junction single (Single T) equal or unequal with acess door opening for cleaning |
| 39 | S&F 110mm bore PVC (SWR) Cowl for vent |
| 40 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement incl 100 mm dia CP NT cover complete |
| 41 | M&LPVC (SWR) gully trap 125/110mm setting and jointing with solvent cement. |
| 42 | PVC (SWR) 110mm junction single, (Single T) equal or unequal |
| 43 | PVC (SWR) 75 mm junction single, (Single T) equal or unequal |
| 44 | S&F 110mm PVC (SWR) couplers |
| 45 | S&F 75mm PVC (SWR) couplers |
| 46 | S&F in repair CP grating doom 100/125mm dia with or without waste hole etc complete all as specified and directed. |
| 47 | Fixing in repair for Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)but half stall urinal complete all as specified and directed. |
| 48 | Material only for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) |
| 49 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 50 | S&F for Welded steel wire fabric supplied and fixed complete to wood or steel members in available size weightnot exc. 4.00 kg per Sqm complete all as specified and directed. |
| 51 | M & L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed. |
| 52 | Removingexisting water proofing treatment of any type all as directed by Engineer-in-charge and disposing off out side Defence Land . |
| 53 | M&L for cement concrete 1:3:6 type C1 (20mm graded stone aggregate) as in RCC roof surface with mixing of water proofing compound 3% by the weight cementto horizontal or vertical surfaces finished cement concrete surface even and smooth using extra cement including necessary form workNote:- (Water proofing compound will be measured separately) |
| 54 | M & L for preparation ofnewly plastered surfaces of roof including cleaning the surface by using wire brush/pressure hose and applying high performance polyurethane liquid membrane roof casting cold in two coats @ 1.5Kg/Sqm with spray/brush an elogation of 300% to 700% and tensile strength not less than 3 N/Sqm as per ASTM D412 and ASTMD2370, crack bridging ability of 3.5mm as per ASTM C 1305, shore a hardness of not less than 60 as ASTMD 2240. The item includes epoxy prime applied @ 0.15 Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet complete as per manufacturer\"s instruction and sound engineering practice complete all as specified and directed. Note - work shall be executed by authorized applicator of manufacture as per manufacturer\"s instructions. |
| 55 | Supply only Integral WPC all as specified and directed |
| 56 | Demolition of cement concrete (unreinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 57 | M & L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection finish without using extra cement complete all as specified and directed. |
| 58 | Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. |
| 59 | Removing excavated material n. exc. 50m and depositing where directed at alevel n. exc. 1.5m above the starting point etc complete all as specified and directed. |
| 60 | M & L for 100mm thick broken stone & boulders hardcore of guage not exc 63mmdeposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 61 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base flooring complete all as specified and directed |
| 62 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 63 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping & benching etc complete all as specified and directed. |