| 1 | Supplying, laying, jointing with suitable size of thimble, connecting and testing in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100V grade with stranded aluminium conductor laid in trenchesfixed to pole, including jointing & testing complete all as specified and directed of size 6 Sqmm 2 core. Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. |
| 2 | All as per item No. 1 above but of size 10 Sqmm 2 core |
| 3 | All as per item No. 1 above but of size 16 Sqmm 4 core |
| 4 | All as per item No. 1 above but of size 25 Sqmm 4 core |
| 5 | All as per item No. 1 above but of size 35 Sqmm 3.5 core |
| 6 | All as per item No. 1 above but of size 50 Sqmm 3.5 core |
| 7 | All as per item No. 1 above but of size 70 Sqmm 3.5 core |
| 8 | All as per item No. 1 above but of size 120 Sqmm 3.5 core |
| 9 | All as per ser item No 1 here in before but of 95 Sqmm 3.5 core |
| 10 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etcall as directed by Engr-in-charge. |
| 11 | M&L for laying dry bricks old size with subclass \"B\" made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable all as specified and directed |
| 12 | Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cmafter laying of cables including spreading, levelling, and well ramming complete all as specified and directed. |
| 13 | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed. |
| 15 | M&L for Tubes, \"light grade\" 40mm dia, galvanised, with all fitting and fixed complete to walls and ceilings or laid in trenches. |
| 16 | M&L for Tubes, \"light grade\" 50mm dia, galvanised, with all fitting and fixed complete to walls and ceilings or laid in trenches. |
| 17 | M&L for Tubes, \"light grade\" 80mm dia, galvanised, with all fitting and fixed complete to walls and ceilings or laid in trenches. |
| 18 | Supply and fixing in replacement of U/S LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box andfixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all asspecified anddirected. |
| 19 | Supply and fixing in replacement of U/S LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box andfixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all asspecified anddirected. |
| 20 | Material and labour for providing PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole etc., including dismantling/ breaking the existing concrete all as specified including necessary form work if required and applying cement mortar topping for fair and smooth finish to exposed surfaces of coping/platform complete all as specified ansd as directed. |
| 21 | Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5mbelow normal ground level, connected to galvanized iron strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electricalplate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as directed.Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc.(b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GIlead wire and protection pipe upto 7.5 meter beyond the earth plates electrode. |
| 22 | S&F for fixing of GI pipe (light grade) bracket of 40mm diasize of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed. |
| 23 | S&F Cable PVC insulated and FR PVC round sheathed copper conductor 2 core AC 1100 Volts grade 1.5 sqmm size and required flexible conduit etc all as specified and directed. |
| 24 | S&F in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Ampsincluding embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red color on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer. |
| 25 | Painting to existingof steel poles 11/9 Mtr long long with one coat of synthetic enamel paint in alternate strips of blackand yelow colours 30 cm height each total 05 Nos commencing form the top of PCC coping incuding painting of coss arms, nut bolts, clamps etc as fixed on pole with tow coats of aluminium paint and marking pole No with paint as per approved pattern, complete all specified (Numbring shall be hand written only, size of letter 100X10mm (Heightxwidth)) |
| 26 | M&L for preparing old painted of LT Panels/feeder pillars including cleaning, rust removal, applying primer where required and finishing with 2 coats of super enamel paint over a coat of red-oxide with sparygun, including masking complete all as specified and directedas directed by the Eng - in - Charge . |
| 27 | Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed.(PCC will be paid seperately) |
| 28 | Material and labour for replacement of damaged hinges of LT panel, including dismantling of existing hinges, cleaning of surface from dust and grease and fixing of SS heavy duty hinges of suitable size, aligning the panel door, welding or bolting as required as specified and directedby the Eng - in - Charge . |
| 29 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 V LT cables of differentsizesfrom both ends, removal of Fault,Re-connections and testing of cables after removal of fault complete all as specified and directed.Note: (a) Cable & joints shall be measured and paid seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/brickswill be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs.(c) Excavation and earth work will be included under respective items of schedule. |
| 30 | Supply, fixing and testing LT straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :- |
| 31 | 25-50 Sqmm x 3.5 core/ 4 core |
| 32 | 70-150 Sqmm x 3.5 core |
| 33 | Supply, fixing of Al thimble for LT cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :- |
| 34 | 16 sqmm 4 core |
| 35 | 25 Sqmm x 3.5 core |
| 36 | 35 Sqmm x 3.5 core |
| 37 | 50 Sqmm x 3.5 core |
| 38 | 70 Sqmm x 3.5 core |
| 39 | 95 Sqmm x 3.5 core |
| 40 | 120 Sqmm x 3.5 core |
| 41 | Supply, fix in replacement of MCCB 400 Amps, 4 Pole 415 V, Adjustablethermal & Adjustable magentic type with breaking capacity 36 KA and ICS = 100% ICU with spreader links, etc complete all as specified and directed |
| 42 | All as per ser item No 38 here in before but ofMCCB 250 Amps, 4 Pole 415 V Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU complete all as specified and directed |
| 43 | All as per ser item No 38 here in before but ofMCCB 200 Amps, 4 Pole 415 V Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICUcomplete all as specified and directed |
| 44 | All as per ser item No 38 here in before but of MCCB 160 Amps, 4 Pole 415 VAdjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU complete all as specified and directed |
| 45 | All as per ser item No 38 here in before but ofMCCB 100 Amps, 4 Pole 415 V,Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICUcomplete all as specified and directed |
| 46 | All as per ser item No 18 here in before but ofMCCB 63 Amps, 4 Pole 415 V Adjustablethermal & Fixed magentic type with breaking capacity 10 KA and ICS = 100% ICU complete all as specified and directed |
| 47 | Supply, install, testing and commissioning outdoor Feeder piller panel board kiosk type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with Copper bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etcINCOMING :-(a) MCCB 500A, 415V, 4 poleAdjustablethermal & Adjustable magentic type with breaking capacity 36 KA and ICS = 100% ICU with over load short circuit protection - 1 Nos(b) Multi function meter for measuring V,A,F,kW,KVA including CTs of suitable capacity - 01(c) LED Phase Indication lamp (RYB) -01 Set of threeOUTGOING:-(a) MCCB 320A, 415V, 4 poleAdjustablethermal & Adjustable magentic type with breaking capacity 36 KA and ICS = 100% ICU with over load short circuit protection - 1 Nos(b) MCCB 125 Amps, 4 Pole 415 V,Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU - 01 Nos(c) MCCB 100 Amps, 4 Pole 415 V,Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU-01 Nos(d) MCCB 63 Amps, 4 Pole 415 V Adjustablethermal & Fixed magentic type with breaking capacity 10 KA and ICS = 100% ICU - 01 Nos(e) Wiring of above accessory with suitable size of copper conductor cable |
| 48 | Supply, install, testing and commissioning outdoor Feeder piller panel board kiosk type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with Copper bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etc:-INCOMING:-(a)MCCB 320A, 415V, 4 poleAdjustablethermal & Adjustable magentic type with breaking capacity 36 KA and ICS = 100% ICU with over load short circuit protection - 1 Nos(b) Multi function meter for measuring V,A,F,kW,KVA including CTs of suitable capacity -01(c) LED Phase Indication lamp (RYB) - 01 Set of threeOUTGOING:-(a)MCCB 250 Amps, 4 Pole 415 V Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU - 01 Nos(b) MCCB 63 Amps, 4 Pole 415 V Adjustablethermal & Fixed magentic type with breaking capacity 10 KA and ICS = 100% ICU - 02 Nos(c) Wiring of above accessory with suitable size of copper conductor cableNote for item No 44.00 & 45.00:-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. (iii) Front and back openable. |
| 49 | Supply and fixing in replacement of automatic change over switch on load single phase, 220 Volts 50 Hz 63 Amps open execution type mounted on existing any type/ description of LT Panel/ feeder pillar with minor modifications of existing LT Panel/ Feeder Pillar box to fix and connecting terminals and making fresh connections of existing cables are deemed in quoted rate of this item and complete. |
| 50 | Supply and fixing in replacement of automatic change over switch on load 4 pole, 415 Volts 50 Hz 100 Amps open execution type mounted on existing any type/ description of LT Panel/ feeder pillar with minor modifications of existing LT Panel/ Feeder Pillar box to fix and connecting terminals and making fresh connections of existing cables are deemed in quoted rate of this item and complete. |
| 51 | Supply and fixing in replacement of change over switch on load 4 pole, 415 Volts 50 Hz 160 Amps open execution type mounted on existing any type/ description of LT Panel/ feeder pillar with minor modifications of existing LT Panel/ Feeder Pillar box to fix and connecting terminals and making fresh connections of existing cables are deemed in quoted rate of this item and complete. |
| 52 | Supply and fixing in replacement of change over switch on load 4 pole, 415 Volts 50 Hz 125 Amps open execution type mounted on existing any type/ description of LT Panel/ feeder pillar with minor modifications of existing LT Panel/ Feeder Pillar box to fix and connecting terminals and making fresh connections of existing cables are deemed in quoted rate of this item and complete. |
| 53 | Supply and fixing in replacement of change over switch on load 4 pole, 415 Volts 50 Hz 100 Amps existing cables are deemed in quoted rate of this item and complete. |
| 54 | Supply and fixing in replacement of change over switch on load 4 pole, 415 Volts 50 Hz 63 Amps existing cables are deemed in quoted rate of this item and complete. |
| 55 | Cutting of road / PCC path upto the depth of pipes and making good the disturbed surface with PCC 1:2:4 (20mm aggregate) using extra cementincluding earth work complete all as specified and directed |
| 56 | Taking down the existing UNSV PVC insulated aluminuim conductor and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with innersheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm stranded conductor complete all as specified & directed by Engr-in-Charge. (Make - Havells/Plaza/Finolex/Kalinga) |
| 57 | All as per item no 47 above but size 16 sqmm. |
| 58 | Supply and fixing ofsheet metal enclosure double door for DBs Triple pole and neutral for 4 way 240 volt complete all as specified and direct by Engineer-in-Charge . |
| 59 | Supply and fix in replacement of32 amps change overdouble pole with side operated handle, 230 volt AC, 50/60Hz,Make : Havells Cat no IHBFDE0032 or equavalent as approved by Engineer-in-Charge. |
| 60 | Supply and fix in replacement of Bus bar chamber box in sheet metal enclosure of 100 Amps capacity ( stand type with four legs) , 4 way, 415 V complete all as directed by Engineer-in-Charge as per Havells Cat Part No IHBC010004 or equivalent make and model. |
| 61 | Supply & fixing in repair of Busbar chamber with pure copper strips of size 36\"\" x 18\"\" x 6\"\" of 400Amps HSN Code: 8536, complete all as specified and as directed |
| 62 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with Copper bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned itemsIncoming:-(a)MCCB 250 Amps, 4 Pole 415 V Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU - 01 Nos(b) Onload changeover 250 amps -01 (c) Digital Voltmeter 0 to 500 Volt -01 No(d) Digital Ammeter 0 to 400 Amps with CTs and selector switch - 01 set(e) LED Phase Indication lamp (RYB) -01 SetOutgoing:-(a) MCCB 100 Amps, 4 Pole 415 V,Adjustablethermal & Adjustable magentic type with breaking capacity 25 KA and ICS = 75% ICU-02 Nos(b) ) MCCB 63 Amps, 4 Pole 415 V Adjustablethermal & Fixed magentic type with breaking capacity 10 KA and ICS = 100% ICU - 02 Nos |
| 63 | Supply,installation, testing and commissioning in replacement of factory made and tested bus bar chamber mde out of 3.15mm CRCA MS sheet. And 40x40x5 mm thick MS angle iron frame work, powder coated finish over frame work,powder coated finish over one coat of red oxide primer an outside one coat of red oxide primer,front opening type with apron for cable entry closing locking arrangement of size 450mm x450mm x300mm with 4 Nos 500 amp aluminium bus bar chamber and with 320 amp MCCB 4 pole 36KA,415 Volt 50 HZ including excavation earth work andplateform for the bus bar chamber with PCC 1:4:8 type D-2 with 40mm graded crushed stone.15cm thick in foundation,brick work in CM 1:6 on exposed surface and 100mm thick PCC padding type C-1using 20mm graded crushed stone aggregate on top and grouting bolt etc for bus bar chamber. The plateform shall be such that it is of a height 45cm above the nearest road level |
| 64 | Schedule of Credit |