| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for taking out/laying of CI/DI/GI pipe lines/ UG cable etc, forming bottom of trenches to the required level and gradient and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 3 | Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed. |
| 4 | Taking up or down GI steel tubing of 20mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 5 | Taking up or down GI steel tubing of 25/32mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 6 | Taking up or down GI steel tubing of 40mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 7 | Taking up or down GI steel tubing of 50mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 8 | Taking up or down GI steel tubing of 80mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 9 | Taking up or down GI steel tubing of 100mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 10 | Taking up or down GI steel tubing of 150mm bore including connections from trenches/walls/floors etccomplete all as specified and as directed. |
| 11 | Taking up cast iron water mains80mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse |
| 12 | Taking up cast iron water mains 100mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse |
| 13 | Taking up cast iron water mains 150mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse |
| 14 | M&L 90mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 15 | M&L 63mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 16 | M&L 50mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 17 | M&L 40mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 18 | M&L 32mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 19 | M&L 25mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 20 | Fixing only 20mm bore GI tubing with new fittings fixed to to walls and ceilings or laying in floors and making good to walls complete all as specified and as directed.Note:- Serviceable Pipe obtained from Item No 4 here-in-before shall be reused |
| 21 | Fixing only 25mm bore GI tubing with new fittings fixed to to walls and ceilings or laying in floors and making good to walls complete all as specified and as directed.Note:- Serviceable Pipe obtained from Item No 5 here-in-before shall be reused |
| 22 | S&F in repair, 63mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 23 | S&F in repair, 50mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 24 | S&F in repair, 40mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 25 | S&F in repair, 32mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 26 | S&F in repair, 25mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 27 | Making connection of PP-R distribution branch with PP-R main of size 16mm to 40mm outer dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed |
| 28 | Making connection of PP-R distribution branch with PP-R main of size 50mm to 90mm outer dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed |
| 29 | Supply, laying and testing GI pipe, Medium Grade, 40 mm bore with all fittings; laid in trenches,complete all as specified and as directed. |
| 30 | Supply, laying and testing GI pipe, Medium Grade, 50 mm bore with all fittings; laid in trenches,complete all as specified and as directed. |
| 31 | Supply, laying and testing GI pipe, Medium Grade, 80 mm bore with all fittings; laid in trenches,complete all as specified and as directed. |
| 32 | Supply, laying and testing GI pipe, Medium Grade, 100 mm bore with all fittings; laid in trenches,complete all as specified and as directed.Note:(i) GI Flanged sockets, rubber board gasket, nuts bolts where ever required shall be measured and paid seperately under respective item at Supply only rates(iii) Labour cost involved for replacement of Flanged sockets, rubber board gasket, nuts bolts etc shall be included in the UNIT RATE QUOTED |
| 33 | Supply, laying and testing GI pipe, Medium Grade, 150 mm bore with all fittings; laid in trenches,complete all as specified and as directed.Note:(i) GI Flanged sockets, rubber board gasket, nuts bolts where ever required shall be measured and paid seperately under respective item at Supply only rates(iii) Labour cost involved for replacement of Flanged sockets, rubber board gasket, nuts bolts etc shall be included in the UNIT RATE QUOTED |
| 34 | Laying Only GI pipe, Medium Grade, 100 mm bore with all fittings; laid in trenches,complete all as specified and as directed.Note:(i) Serviceable Pipe obtained from Item No 9 here-in-before shall be reused(ii)GI Flanged sockets, rubber board gasket, nuts bolts where ever required shall be measured and paid seperately under respective item at Supply only rates(iii) Labour cost involved for replacement of Flanged sockets, rubber board gasket, nuts bolts etc shall be included in the UNIT RATE QUOTED |
| 35 | Supply only GI Flange 100mm borecomplete all as specified and as directed.Note:- Mild steel nuts biolts, washers, rubber gasket etc as required shall be deemed to included in the UNIT RATE QUOTED |
| 36 | Supply only GI Flange 150mm borecomplete all as specified and as directed.Note:- Mild steel nuts biolts, washers, rubber gasket etc as required shall be deemed to included in the UNIT RATE QUOTED |
| 37 | Supply only Rubber/EPDM gasket 4mm thick complete all as specified and as directed |
| 38 | S&F in repair, 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 39 | S&F in repair, 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 40 | S&F in repair, 32mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 41 | S&F in repair, 40mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 42 | S&F in repair, 50mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 43 | Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 150mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately . |
| 44 | Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 100mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately . |
| 45 | Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 80mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately . |
| 46 | S&F DI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch. \"Y\" junction, double branch, cross collars, caps and plugs for Pipe upto 300mm bore complete all as specified and as directed. |
| 47 | M&L Cast Iron Sluice Valve 80 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed. |
| 48 | M&L Cast Iron Sluice Valve 100 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed. |
| 49 | M&L Cast Iron Sluice Valve 150 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed. |
| 50 | Supply and Fixing cast iron body and brass gate heavy duty non return valve ( NRV) 100 mm bore with flanged endall necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceablenon return valve ( NRV), complete all as specified and as directed. |
| 51 | Supply, laying and testing MS patch clamp orleak repairing clamp complete with accesories havingbore/ dia 80mm for repair of leakage/ break down of DI pipes complete all as directed |
| 52 | Supply, laying and testing MS patch clamp orleak repairing clamp complete with accesories havingbore/ dia 100mm for repair of leakage/ break down of DI pipes complete all as directed |
| 53 | Supply, laying and testing MS patch clamp orleak repairing clamp complete with accesories havingbore/ dia 150mm for repair of leakage/ break down of DI pipes complete all as directed |
| 54 | Supply, laying and testing MS patch clamp orleak repairing clamp complete with accesories havingbore/ dia 200mm for repair of leakage/ break down of DI pipes complete all as directed |
| 55 | M&L Burning out lead joint in position,80mm bore including recovering old lead, complete all as directedNote- Excavation,wherever required shall be measured and paid separately under appropiate item. |
| 56 | M&L Burning out lead joint in position,100mm bore including recovering old lead, complete all as directedNote- Excavation,wherever required shall be measured and paid separately under appropiate item. |
| 57 | M&L Burning out lead joint in position,150mm bore including recovering old lead, complete all as directedNote- Excavation,wherever required shall be measured and paid separately under appropiate item. |
| 58 | M&L Burning out lead joint in position, 200mm bore including recovering old lead, complete all as directedNote- Excavation,wherever required shall be measured and paid separately under appropiate item. |
| 59 | M&L run lead joints for pipes and fittings (spigot and socket ends) 80 mm bore (dia) and testing complete all as specified and asdirected. |
| 60 | M&L run lead joints for pipes and fittings (spigot and socket ends) 100 mm bore (dia) and testing complete all as specified and asdirected. |
| 61 | M&L run lead joints for pipes and fittings (spigot and socket ends) 150 mm bore (dia) and testing complete all as specified and asdirected. |
| 62 | M&L run lead joints for pipes and fittings (spigot and socket ends) 200 mm bore (dia) and testing complete all as specified and asdirected. |
| 63 | Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 100mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE :Serviceable lead retrived from burning out of lead joints to be reused. |
| 64 | Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 150mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE :Serviceable lead retrived from burning out of lead joints to be reused. |
| 65 | M&L Construction Brick Masonry Valve Pit of size 600x600x600 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and asdirected. |
| 66 | M&L Construction Brick Masonry Valve Pit of size 750x750x750mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and asdirected. |
| 67 | M&L Construction Brick Masonry Valve Pit of size 900x900x900 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and asdirected. |
| 68 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 150 mm bore (dia) for passing of pipes, complete all as specified and as directed.Note:- GI pipe will be measured and paid seperately under appropiate item |
| 69 | M&L PCC Type B2 1:2:4(40mm graded aggregate) as in foundations/filling in mass concrete including necessary formwork as required, complete all as specified and as directed. |
| 70 | Servicing / over hauling of 3 Phase 415 Volts 1440 RPM 20 HPMotor (Make-Kirloskar)) Installed atAIR OP pump House coupled with NC Horizontal Pumping set. a). Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections b) Dismantling of induction Motor complete part by part carefully , testing all coils , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.c) Heating & varnishingto stator with super quality varnish and dried out properely with external heat as ordered & directedd). Reassembeling the motor complete with all existingserviceable parts obtained, greasing the bearing with bearing grease , andnew parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under relevant Itemhere-in after) e) Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completionNote :- (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoated against this Item.(ii). Any unforeseen minor repair and minor parts ( Total cost less than Rs 200 ) that are not covered under Item No- 88to 91but required to complete the repair work / smooth functioning of Motor shallbe deemed to be included with the unit rate .Transportation of Stator / Rotorparts for machining , rewinding at lathe shop at Tezpur / Rangapara is also deemed to be included with unit rate.iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 71 | Supply onlyDE ( Driver End ) bearing as per existing size suitable for 20 HP Motor to incorporate against each Item No-70 here-in-above completeall as specified and as directed. |
| 72 | Supply onlyNDE ( Non Driver End ) bearing as per existing size suitable for 20 HP Motor to incorporate against each Item No-70 here-in-above completeall as specified and as directed. |
| 73 | Supply only Bakelite connection plate with brass nuts bolts and washers suitable for 20 HP Motor to incorporate against each Item No-70 here-in-above completeall as specified and as directed. |
| 74 | Supply only Plastic Rotor Fan suitable for 20 HP Motor to incorporate against each Item No-70 here-in-abovecomplete all as specified and as directed. |
| 75 | Supply only Rubber tyre Coupling complete set suitable for 20 HP Motor to incorporate against each Item No. 70 here-in-above complete all as specied and as directed. |
| 76 | Rewindingburnt coilsof Induction Motor stator cap 20 HP obtained from Item Ser No-70 here-in-above with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots, completeas directed. |
| 77 | M&L cutting/Cleaning amd removing of all unwanted vegetations, bushes, grasses, roots ,etcand removing to a distance not exc 50mtrs complete all as specified and as directed. |
| 78 | M& L preparation to CI/DI MS rising, distribution, overflow, wash out and suction pipe line of dia 150mm to 300 mm in vertical/ horizondal position and painting two coat of super enameled black or sky blue paint over a coat of red oxcide duly marked inlet/outlet direction, overflow/ washout at various water supply installation/ OHT at any height/ staging under GE Missamari all as directed Note: Therate quoted id deemed to inclusive for making arrangement for stage/ ladder for painting work. |
| 79 | M&L preparation ofoldsteel surfaces of valve pit chamber cover with angle iron frame of size 900mm x 900mm and applyingone coat of super enameled black paint complete all as specified and as directed |
| 80 | Supply, Installation, commissioning and Testing Chlorine Pressure Feed Pump high pressure single head gear motorised adjustable Dozing pump with acessories including Lead Tubing, Connection Nuts, Injection Check Valves, Clay Weight, FRP Dosing tank and Ferrules including taking out/removal of old unserviceable one complete all as directed. |
| 81 | Servicing / over hauling of 3 Phase 415 Volts 1440 RPM 10 HPMotor (Make-Kirloskar)) Installed atAIR OP pump House coupled with NC Horizontal Pumping set. a). Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections b) Dismantling of induction Motor complete part by part carefully , testing all coils , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.c) Heating & varnishingto stator with super quality varnish and dried out properely with external heat as ordered & directedd). Reassembeling the motor complete with all existingserviceable parts obtained, greasing the bearing with bearing grease , andnew parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under relevant Itemhere-in after) e) Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completionNote :- (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoated against this Item.(ii). Any unforeseen minor repair and minor parts ( Total cost less than Rs 200 ) that are not covered under Item No- 88to 91but required to complete the repair work / smooth functioning of Motor shallbe deemed to be included with the unit rate .Transportation of Stator / Rotorparts for machining , rewinding at lathe shop at Tezpur / Rangapara is also deemed to be included with unit rate.iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 82 | Supply onlyDE ( Driver End ) bearing as per existing size suitable for 10 HP Motor to incorporate against each Item No-81 here-in-above completeall as specified and as directed. |
| 83 | Supply onlyNDE ( Non Driver End ) bearing as per existing size suitable for 10 HP Motor to incorporate against each Item No-81 here-in-above completeall as specified and as directed. |
| 84 | Supply only Bakelite connection plate with brass nuts bolts and washers suitable for 10 HP Motor to incorporate against each Item No-81 here-in-above completeall as specified and as directed. |
| 85 | Supply only Plastic Rotor Fan suitable for 10 HP Motor to incorporate against each Item No-81 here-in-abovecomplete all as specified and as directed. |
| 86 | Rewindingburnt coilsof Induction Motor stator cap 10 HP obtained from Item Ser No-81 here-in-above with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , completeas directed. |
| 87 | Servicing / over hauling of 3 Phase 415 Volts 1440 RPM 05 HPMotor (Make-Kirloskar)) Installed atAir Force SMQ area coupled with NC Horizontal Pumping set. a). Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections b) Dismantling of induction Motor complete part by part carefully , testing all coils , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.c) Heating & varnishingto stator with super quality varnish and dried out properely with external heat as ordered & directedd). Reassembeling the motor complete with all existingserviceable parts obtained, greasing the bearing with bearing grease , andnew parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under relevant Itemhere-in after) e) Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completionNote :- (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoated against this Item.(ii). Any unforeseen minor repair and minor parts ( Total cost less than Rs 200 ) that are not covered under Item No- 88to 91but required to complete the repair work / smooth functioning of Motor shallbe deemed to be included with the unit rate .Transportation of Stator / Rotorparts for machining , rewinding at lathe shop at Tezpur / Rangapara is also deemed to be included with unit rate.iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 88 | Supply onlyDE ( Driver End ) bearing as per existing size suitable for 5 HP Motor to incorporate against each Item No-87 here-in-above completeall as specified and as directed. |
| 89 | Supply onlyNDE ( Non Driver End ) bearing as per existing size suitable for 5 HP Motor to incorporate against each Item No-87 here-in-above completeall as specified and as directed. |
| 90 | Supply only Bakelite connection plate with brass nuts bolts and washers suitable for 5 HP Motor to incorporate against each Item No-87 here-in-above completeall as specified and as directed. |
| 91 | Supply only Plastic Rotor Fan suitable for 5 HP Motor to incorporate against each Item No-87 here-in-abovecomplete all as specified and as directed. |
| 92 | Rewindingburnt coilsof Induction Motor stator cap 5 HP obtained from Item Ser No-87 here-in-above with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , completeas directed. |
| 93 | Scraping old paint of Electric induction Motor 20/15/10/5 HP Motor , NC Vertical/ Horizontall Split casing Pump , Suction , delivery Pipes, sluice valves , NRV Valvesat Jalkendra , IMPH Pump House (Approx coverage area: 8-10 Sqm) and Painting with onecoats of red oxide paint and two coat of syntheticenameal paint of shade as directed by Engnr-in-Charge including writing Sm No. MES No.complete as all specified and as directed |
| 94 | Supply of JCB/Fork land for removal of Silt/Gravels in the open drain from Ghabharu River to sand catcher at Jalkendra all as specified and directed by EIC Note:- (a) Rate quoted is deemed to inclusive of payment of Driver, Feul, Coolent, Lubricant or any other acessories as required (b) No additional charges will be paid for the T&P required.(c) Work shall be carried out only in written orders of Engg-In-Charge, and duty roster mentioning the Vechile Registration No. shall be maintained for start time and end time, date wise signed by JE, Engg-In-Charge,Contractor dully countersigned by GE. Photographic evidence shall be submitted to Engg-In-Charge as demanded and cost of Photos (One Photo per hour) is deemed to be inclusive in the unit rate quoted. |
| 95 | M&L for cleaning of semi underground sumps of 20000 Gallon capacity each through 7 stages of cleaning and sterilization consisting of the following stages complete all as specified and as directed. Location of work : Air Force Pump OHT(a) First stage : MECHANIZED DEWATERING: This first stage consists of emptying water from the tank. A submersible pump is used to drain the tank of excess of water. Removal of water and semi sludge with the help of Sludge pump (electrical/hydraulic).(b) Second stage : SLUDGE REMOVAL: A sophisticated suction process is used to drain the excess sludge out of tank at a safe place away from tank. Removal of mud, sand and solid particles up to 4 inch size with the hydraulic sludge pump.(c) Third stage : HIGH PRESSURE CLEANING: The tank is then cleaned using high pressure jet machine. The rotary jet is used to clean walls and ceilings, whereas plain jet is used to clean the corners of the tank. The rotary jet acts as scrubber and can clean the most stubborn depositions. Cleaning of floor, walls and ceiling with the help of German made high pressure rotary jet pump having pressure range between 80-180 bars.(d) Fourth stage :MECHANIZED SCAVENGING: Mechanical scavenging using Eco-friendly, Health & Safety disinfecting chemical for removing rest over algae in water storage tank\"s wells to insure minimum harmful pathogens.(e) Fifth stage: VACUUM CLEANING: The additional sludge and impurities are then removed by using a Heavy Duty industrial vacuum cleaner and are again disposed at a safer place away from the water tank. An industrial Vacuum pump is then used to clean the leftover physical impurity from the floor.(f)Sixth stage : ANTIBACTERIAL SPRAY: After above steps of cleaning, the tank is treated with a food Graded antibacterial spray FDA recommended disinfecting chemicals to make it completely bacteria free and safe for use.(g) Seven stage : 360 UV STERILIZATION: The water storage tank is then treated with 360 ultra-violet (UV) radiator to make it bacteria free and safe for storing your drinking water. A specially developed UV Radiator is used to kill suspended or floating bacteria remaining in the tank.(Item Contd....) |
| 96 | Note : - (I) All T&P, PPE Kit, Transport shall be provided by the contractor without charging any extra cost.(II) ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (III) Date of cleaning of tank should be written on the outer surface of tank in white letter over black background complete all as direceted NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF CHEMICALS TO BE USED, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. (V) THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY |
| 97 | All as per Item No 95 here-in-before above complete but for underground sumpsof 01 Nos of20000 Gallon capacityLocation of work : AF pump house |
| 98 | S&F Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 (Gde E-165) and applying a coat of red oxide zinc chrome primer including dismantling/taking out old unserviceable one completeall as specified and as directed. |
| 99 | S&F frame of motor pump set of capacity 70/75 HP with MS angle covering the same with MS sheet, shape and size as per requirement/as directed conforming to Fe-290 (Gde E-165) and applying a coat of red oxide zinc chrome primer including dismantling/taking out old unserviceable one completeall as specified and as directed. |
| 100 | Desliting/Taking out accumulated Silt, Sand , Mud etc.,from Jack well of diameter 6.10 Metre and 12.20 Metre deep ( installed at Jalkendra ) through Manhole, removing the same to a distance not exc. 50 Metre, complete all as specified and as directed. Note : The contractor to monitor day to day and avoid damage of VT pumpset due to intake of sand/mud(accumulated into bowl assembly Note:- Any damage made to Jack well, the contractor is fully responsible for repair the same without any extra payment. |
| 101 | Desliting / Taking out accumulated Silt, Sand ,Mud etc from Sand Trap of diameter 2.30 Metre and 3.00 Metre deep (installed at Jalkendra ) through Manhole, removing the same to a distance not exc. 50 Metre and depositing, complete all as specified and as directed. |
| 102 | Desliting / Taking out accumulated Silt, Sand ,Mud etc from Sand Catchment near River Bed Collection Chamber of Size 18.25 Metre x 4.57 Metre and 2.45 Metre deep , removing the same to a distance not exc. 50 Metre complete all as specified and as directed. |
| 103 | Desliting / Taking out accumulated sludge , Silt , Mudetc., from Flocculation Chamber, Flush mixing chamber , Clarifier Chamber , connected channels including scrapping down and cleaning internal surface of walls , Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels , pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre complete all as specified and as directed. |
| 104 | Desliting / Taking out accumulated sludge , Silt , Mudetc., from Aeration Chamber installed at Jalkendra including scrapping down and cleaning internal surface of walls , Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels , pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and depositing complete all as specified and as directed. |
| 105 | Scrapping down , cleaning Internal Surfaces of Walls, Floors, Roofs, Drainage system etc of Under Ground Clear water sump ( installed at Jalkendra,) of size 30.00 x 30.00 x 2.60 Metre including removing the accumulated sand/ silt from the chambers, depositing where directed atdistance not exc. 50 Metre complete all as specified and as directed. |
| 106 | Desilting/Taking out accumulated Silt, mud etc from temporary open channels of size 1.5 metre wide and 5 metre deep, connecting from main stream of river Gabru to sand trap near Jackwell at Jalkendra including removing the accumulated sand/ silt from the channels depositing where directed atdistance not exc. 50 Metre complete all as specified and as directed. |
| 107 | Desilting of Sludge Pit and Manhole to bring water from river to collection chamber/jackwell at Jalkendra including removing the accumulated sand/ silt from the channels depositing where directed atdistance not exc. 50 Metre complete all as specified and as directed. |
| 108 | Repair to water level indicator ofOH Reservoirby replacement of brass float ball 300 mm dia 2mm thick mild steel pulley flexible steel wire rope from brass float ball to measuring key and painting to indicator with 2 coat of synthetic enamelpaint and marking number, strip for measuring of water level at OHT with red/black/Yellow reflective type colour complete and all as directed. |
| 109 | Repair/Servicing ofAir Conditioner split type at site (Air Conditioner comprises wiith out door and Indoor Unit complete) 1.5 TR Capacity of any Make and any type by replacing unserviceable parts from the machine including charging of refrigerant gas after vacuuming and leak testing, brazing suction/ discharge tubes where required and cleaning of condensing unit to achieve proper cooling effect, checking of electronic circuit of the machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires and cleaning of AC using air blower as ordered, reinstallation the Air Conditioner at location where directed after proper repairing and testing complete at site, complete all as specified and as directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 110 | Repair/Servicing ofAir Conditioner split type at site (Air Conditioner comprises wiith out door and Indoor Unit complete) 2 TR Capacity of any Make and any type by replacing unserviceable parts from the machine including charging of refrigerant gas after vacuuming and leak testing, brazing suction/ discharge tubes where required and cleaning of condensing unit to achieve proper cooling effect, checking of electronic circuit of the machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires and cleaning of AC using air blower as ordered, reinstallation the Air Conditioner at location where directed after proper repairing and testing complete at site, complete all as specified and as directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 111 | Repairs/Servicing Air Conditioner 1.50 Ton Capacity, Window type at Site of any Make and any type by replacing unserviceable Parts (like Compressor and other Minor Parts viz Capilary Tube, Machine Screws, Washer, Rubber Bush, etc) from the Machine including Charging of Refrigerant Gas after vacuuming and leak testing, brazing the suction/discharge tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect, checking of Electrical Circuit of machine and repair where necessary by replacing proper size PVC insulated Wires and cleaning of AC using air blower as directed, commissioning & Testing, complete all as specified and directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine. |
| 112 | S&F in repair, Starting Relay for 1.5 TR Compressor complete all as specified and as directed. |
| 113 | S&F in repair, Starting Relay for 2 TR Compressor complete all as specified and as directed. |
| 114 | S&F in repair, Over Load Protector for 1.5 TR Compressor complete all as specified and as directed. |
| 115 | S&F in repair, Over Load Protector for 2 TR Compressor complete all as specified and as directed. |
| 116 | S&F in repair, Thermosate for 1.5 TR Compressor complete all as specified and as directed. |
| 117 | S&F in repair, Thermosate for 2 TR Compressor complete all as specified and as directed. |
| 118 | S&F in repair, Sunction copper pipe line heavy duty 1/2\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 119 | S&F in repair, Discharge copper pipe line heavy duty 1/4\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 120 | S&F in repair, Discharge copper pipe line heavy duty 5/8\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 121 | S&F in repair, Discharge copper pipe line heavy duty 3/8\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 122 | S&F in repair, 15mm dia. PVC pipe nylon imbraided flexible drain water pipe (as approved) for condenser water drain pipe fixed with clamps in wall complete all as specified and as directed. |
| 123 | S&F in repair, Foam insulation for copper tubing of size 1/2\" dia complete all as specified and as directed. |
| 124 | S&F in repair, Foam insulation for copper tubing of size 5/8\" dia complete all as specified and as directed. |
| 125 | S&F in repair, Foam insulation for copper tubing of size 1/4\" dia complete all as specified and as directed. |
| 126 | S&F in repair, Foam insulation for copper tubing of size 3/8\" dia complete all as specified and as directed. |
| 127 | S&F in repair, Running Capacitor 36 mfd, 230 Volt, 50 Hz, Pin type suitable for AC of any capacity complete all as specified and as directed. |
| 128 | S&F in repair, Running Capacitor 50 + 4 mfd, 230 Volt, 50 Hz, Pin type suitable for AC of any capacity complete all as specified and as directed. |
| 129 | S&F in repair, Running Capacitor 50 + 6 mfd, 230 Volt, 50 Hz, Pin type suitable for AC of any capacity complete all as specified and as directed. |
| 130 | S&F in repair, Running Capacitor 6 mfd, 230 Volt, 50 Hz, Pin type suitable for AC of any capacity complete all as specified and as directed. |
| 131 | S&F in repair, Running Capacitor 4 mfd, 230 Volt, 50 Hz, Pin type suitable for AC of any capacity complete all as specified and as directed. |
| 132 | S&F in repair, Condensing unit of split AC 1.5 TR with condensing coil unit complete all as specified and as directed. |
| 133 | S&F in repair, Condensing unit of split AC 2 TR with condensing coil unit complete all as specified and as directed. |
| 134 | S&F in repair, Blower motor of split AC 1.5 TR (indoor unit) complete all as specified and as directed. |
| 135 | S&F in repair, Blower motor of split AC 2 TR (indoor unit) complete all as specified and as directed. |
| 136 | S&F in repair, Blower motor of split AC 1.5 TR (Out door unit) complete all as specified and as directed. |
| 137 | S&F in repair, Blower motor of split AC 2 TR (Out door unit) complete all as specified and as directed. |
| 138 | S&F in repair, Swing motor of split AC 1.5 TR ((indoor unit) complete all as specified and as directed. |
| 139 | S&F in repair, Swing motor of split AC 2 TR (indoor unit) complete all as specified and as directed. |
| 140 | Supply and filling ofRefrigerant GasR-22 (as approved) suitable for Air Conditioner split type 1.5/2.0 TR capacity, complete all as specified and as directed. |
| 141 | Supply and filling ofRefrigerant Gas R-32 (as approved) suitable for Air Conditioner split type 1.5/2.0 TR capacity, complete all as specified and as directed. |
| 142 | Supply and filling of Nitrogen Gas for decting of leakages suitable for Air Conditioner split type of any capacity, complete all as specified and as directed. |
| 143 | S&F in repair, Sunction Valve, size 1/2\" complete all as specified and as directed. |
| 144 | S&F in repair, Discharge Valve, size 1/4\" complete all as specified and as directed. |
| 145 | S&F in repair, Sunction Valve, size 5/8\" complete all as specified and as directed. |
| 146 | S&F in repair, Discharge Valve, size3/8\" complete all as specified and as directed. |
| 147 | S&F in repair, cooling unit, any type/size of indoor unit of Split type AC capacity 1.5 TR by cutting the sunction line and discharge line including necessary testing complete all as specified and as directed. |
| 148 | S&F in repair, cooling unit, any type/size of indoor unit of Split type AC capacity 2 TR by cutting the sunction line and discharge line including necessary testing complete all as specified and as directed. |
| 149 | M&L carrying out pressure leak test of split AC 1.5 TR by nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerent pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging complete all as specified and as directed.Nore: Cost of Nitrogen gas will be measure and paid seperately under respective item |
| 150 | M&L carrying out pressure leak test of split AC 2 TR by nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerent pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging complete all as specified and as directed.Nore: Cost of Nitrogen gas will be measure and paid seperately under respective item |
| 151 | M&L carrying out pressure leak test of Window type AC 1.5 TR by nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerent pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging complete all as specified and as directed.Nore: Cost of Nitrogen gas will be measure and paid seperately under respective item |
| 152 | Dismantling defective wiring of indoor unit of Split AC 1.5 TR including cordless electronic remote control, supply and fixing PCB (Printed circuit board) and Visual Eye demo plate to suit/match the existing system complete all as specified and as directed. |
| 153 | Dismantling defective wiring of indoor unit of Split AC 2 TR including cordless electronic remote control, supply and fixing PCB (Printed circuit board) and Visual Eye demo plate to suit/match the existing system complete all as specified and as directed. |
| 154 | S&F PVC insulated, PVC round sheathed copper conductor (flexible) industrial cable FRLS 1100 Volts conforming to IS 694 of size 2.5Sqmm 3 Core, connecting electrical equipments with terminal lugs/clips as per site requirement complete all as specified and as directed. |
| 155 | Taking out existing outdoor unit of split AC including refrigerant lines and electrical connections 1.5 TR/2TR and refixing at new location alongwith fixing arrangement with nuts and bolts complete all as specified and as directed.Note: Refrigerent pipe line, AC outdoor metalic stand, electrical connection cable, drain pipe, topping up refrigerent gas shall be measured separately under appropiate item |
| 156 | Taking out existing Indoor unit of split AC including refrigerant lines and electrical connections 1.5 TR/2TR and refixing at new location alongwith fixing arrangement with nuts and bolts complete all as specified and as directed.Note: Refrigerent pipe line, AC outdoor metalic stand, electrical connection cable, drain pipe, topping up refrigerent gas shall be measured separately under appropiate item |
| 157 | S&F in repair, compressor (as approved) suitable for Air Conditioner 1.5 TR capacity, split type, complete all as specified and as directed. |
| 158 | S&F in repair, compressor (as approved) suitable for Air Conditioner 2 TR capacity, split type, complete all as specified and as directed. |
| 159 | S&F in repair, compressor (as approved) suitable for Air Conditioner 1.5 TR capacity, Window type, complete all as specified and as directed. |
| 160 | Taking down indoor unit of 1.5 TR by preserving the existing gas in oudoor unit, checking and overhauling the complete indoor unit part by part and refixing at the same position and reconnecting lines, testing complete all as specified and as directed. |
| 161 | Taking down indoor unit of 2 TR by preserving the existing gas in oudoor unit, checking and overhauling the complete indoor unit part by part and refixing at the same position and reconnecting lines, testing complete all as specified and as directed. |
| 162 | S&F in repair, metallic stand/Bracket for fixing of oudoor unit of Split AC complete all as specified and as directed. |
| 163 | Cutting and opening of existing brick wall and making good the distrubed surfaces of wall in cement mortar 1:6, thickness of brick wall exc half brick and exc one brick thick wall and finishing the surfaces as per existing finishes, suitable for Window type AC 1.5/2 TR complete all as specified and as directed. |
| 164 | S&F in repair, Timmer for AC duly setting as per PCB configuration and connected wiring complete all as specified and as directed. |
| 165 | S&F in repair, Power contactor 2 Pole coil voltage 230 Volts 25 Amps complete all as specified and as directed. |
| 166 | Supply only Remote control hand set suitable for 2 TR Split AC complete all as specified and as directed. |
| 167 | Supply only Remote control hand set suitable for 1.5 TR Split AC complete all as specified and as directed. |
| 168 | Supply only Remote control hand set suitable for 1.5 TR Window type AC complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail