| 1 | Supply of 3 Lamps PAPI Unit including check stick and clinometer having suitable arrangement for lamp including lamps assembly, halogen lamps, holder/pins, adjustment legs with breakable couplings, filters, spreader assembly, secondary leads of suitable length, Plugs and dust proof housing with air filter etc. complete with all accessories ready for installation conforming to tender specifications and annexure 14 of ICAO with latest upto date amendments. (Each set consists of complete one unit). (1 Set=4 Units) |
| 2 | Supply of 200 watt, 6.6A/6.6A, 5kV, 50 Hz individual lamp series type Isolating Transformer suitable for PAPI lamp encapsulated in polyester resin & finally molded in neoprene rubber with primary and secondary connection leads confirming to technical specifications, terms & conditions etc. as specified in tender document complete as required. |
| 3 | Supply of 1C x 6 sq.mm size 5 KV grade PVC insulated & PVC sheathed, anti-termite & anti-rodent, multi-stranded copper conductor single core Airfield lighting cable confirming to IS 1554 (Part-II) with up-to-date amendments and confirming to technical specifications, terms & conditions etc. as specified in tender document complete as required. |
| 4 | Making field connections of 5 KV grade, 6 sq mm Copper conductor AFL cables with ESNA connector i/c crimping & fixing, applying HT and LT tape complete as required. |
| 5 | Supply of 5 KV grade Plug & Receptacles (ESNA connector) suitable for filled attachment with 5KV grade PVC insulated, PVC Sheathed single core 6 sq mm copper conductor cable confirming to technical specifications etc. as required. |
| 6 | Supplying of 63 mm dia.(Outer) size, DWC HDPE pipe, each length of 6 metre along with all accessories like scoket,bend,couplers etc... ISI marked conforming to IS 14930 Part IIwith upto date amendments etc as required. |
| 7 | Installation, Testing & Commissioning of 3 lamps PAPI unit with base plates including positioning & fixing of checking stick base plate, supply of all required materials for complete installation including designing and providing suitable strength PCC and RCC foundation as per OEM along with PCC pedestal (1:2:4 cement concrete) of 1000mm wide and 200mm thick all around the foundation of each PAPI unit as well as checking base foundation, connection & laying of secondary leads in flexible metal conduit, connections/ inter-connections with isolating transformers including excavation, levelling, sloping and refilling of hard/soft soil etc complete as per site requirements |
| 8 | ITC of transformer housing boxes with all around 100mm thick PCC (1:2:4), top sloped with cement mix including providing and fixing 250 mm long 15 mm dia \"B\" Class GI pipe with check nut for drainage of water including excavation of hard/ soft soil and refilling/leveling etc complete as required. |
| 9 | Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 5 KV grade of 1 x 6 sqmm size in the existing DWC HDPE /RCC /GI /HUME /METAL pipe etc. as required. |
| 10 | Laying of 63mm nominal diaDWC HDPE pipe with all accessories like socket, bend, couplers etc,.complete with fitting and cutting, jointing etc,direct in ground (80 cm below ground level) including excavation and refilling the trench after laying pipe and providing all accessories i.eSocket, bend, couplers etc., complete as required. |
| 11 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing RCC (1:2:4) enclosure with 6mm thick MS cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Providing and laying 4 Sq.mm FRLS wire along with cable for loop earthing |
| 13 | Supply of FAA/ICAO/DGCA‐CAR compliant LED based Runway Guard light upto 65 W for compliance as per ICAO/DGCA‐CAR aviation visual aids requirements complete with LED lamp/s with integral driver, electronics suitable for operation along with existing 2.8‐6.6 Amps current Taxiway Circuit & CCRs, with all accessories and cable lead with plug ready for site installation on circular Housing box ,suitable for all weather operation, conforming to latest ICAO / CAR requirement as per specifications complete as required. |
| 14 | Supply of Up to 65 W, 6.6A/6.6A rating 5000V, 50 Hz Series Isolating Transformers encapsulated in black cross linked polychloroprene compound like TPE /TPR / TPV with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned LED runway Guard light fittings complete as per Technical Specifications. |
| 15 | SITC of Indoor Type Air Cooled Constant Current Regulator (CCR) of Micro Processor Controlled, Thyristor Type suitable for operation on single phase 230V / 2-phase 400V AC + PE ± 10%, 50 Hz input AC supply with 5 steps variation of current output (2.8, 3.4, 4.0, 5.2 and 6.6 Amp) and able to communicate with PC or PLC controlled system with digital output anmeter (0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display complete as required for the following rating and confirm to specifications enclosed andsuitable for operation on the existing Airfield Lighting Control and Monitoring System (ALCMS) with communication, local and remote control and monitoring even and data recording and history keeping etc complete as required.4KW 6.6/6.6A |
| 16 | Installation, testing and commissioning of Runway Guard Lights fittings on the existing transformer housing boxes including installation of Isolating transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories i/c alignment, levelling, connection, earth connection etc. all complete. |
| 17 | Excavation of existing Bituminous/ Concrete road including disposal of material within 50 mtrs lead and providing & laying in position 1:2:4 (1 cement : 2 Coarse sand : 4 Graded stone aggregated of 20 mm nominal size all works up to plinth level to fill up the excavated Bituminous/ Concrete roadafter laying of the cable complete etc. as required. |
| 18 | Supply of 2C x 6 sqmm Airfield Lighting (AFL) 5 KV grade, 2 core Copper Conductor, XLPE insulated, and with inner and outer semiconductor, Polyethylene (PE) outer sheathed, Unarmoured Underground Cable for airfield lighting Primary Circuit, conforming to IS 1554/ IS 7098(part-2) and specification as specified in technical specification. |
| 19 | Laying of one number 2C X 6 sq mm AFL primary cable grade not exceeding 1.1 KV in the cable duct / masonary trench / RCC / HUME / METAL / GI / HDPE / DWC pipe etc. as required. |
| 20 | Providing and laying of 50mm dia B class G.I pipe below 0.5 mtr, across road. complete as required. |