| 1 | Excavating in trenches, exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/loose soil. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out Soft/loose soil |
| 3 | Cement concrete in foundations, filling and mass concrete, type D2 1:4:8 (40 mm graded aggreagate) |
| 4 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings . |
| 5 | Demolition of stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. but built in cement mortar or cement lime mortar . |
| 6 | Removing cement mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including allextra handling and removal and disposing off rubbish |
| 7 | Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6but exceptstone. |
| 8 | Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 |
| 9 | Providing, cement concrete in , copings,type BO 1:2:4( 12.5 mm graaded aggregate) |
| 10 | Raised pointing to random or polygonal rubble, uncoursed or brought upto courses with cement mortar 1:4 |
| 11 | S&F,Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 for posts and struts in fencing Y shape angle |
| 12 | Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 13 | S&F GI concetina coil 600 mm dia (50 turn/coil )expendable 06 to 08 mtr. Fixed on angle iron frame over brick wall/angle post all as specified as directed . |
| 14 | Cement concrete in foundations filling and mass concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases),type B2 1:2:4( 40 mm graaded aggregate) |
| 15 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 16 | M & L painting on steel Surfaces of any description, over 10cm in width or girth,not otherwise described with preparation of new or previously untreated surface with two coats of synthetic enamel paint make Asian,Burger,Nerolac. |
| 17 | M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:4 cement mortar . |
| 18 | Rendering 12mm thick on fair faces of brick work or concrete surfaces cement plaster 1:6 rendering is to be finished even and smooth (without using extra lime or cement). |
| 19 | S&F, Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified. Make:TATA/JINDAL/JSW |
| 20 | S&F, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ridges/valley gutter cladding to wall, fixed with self tapping screws as specified. Make:TATA/JINDAL/JSW |
| 21 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates made with Fe 410 W (Gde-E 250 quality-A) |
| 22 | Cement concrete in surface channel and drain concrete cement type B2 1:2:4 (40 mm graded aggregate) |
| 23 | S&F, Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 24 | M & L 100mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) Finishing cement concretesurface even and smooth Without using extra cement . |
| 25 | Providing precast ce- ment concrete in landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articleswith plain faces TypeB1 1:2:4 (20.00mm graded aggregate) |
| 26 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips TMT bar. |
| 27 | S & F Sluice Valve Class PN 1.6 (100mm dia & 300 mm width) Make kirlosker/jindal/LNT/VIP/ M-Tech. |
| 28 | S& FSluice Valve Class PN 1.6 (150 mm dia & 280to 300 mm width )Make kirlosker/jindal/LNT/VIP /M-Tech. |
| 29 | Tubes,150 MM\"Medium grade, galvanised, with all fitting;laid in trenches |
| 30 | Credit (-) old/unserviceable dismentledold AC sheet. |