Housing Urban and Rular Development Government Departments Closing in 0 days TDR #53303111

Tender For Infrastructure Creation For District Administration Of New District Jiribam Construction Of Dc Bungalow

Issued by Government Departments · jiribam, Manipur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Feb 2026
0 days left
EMD
7.38 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jiribam → Manipur
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Infrastructure Creation For District Administration Of New District Jiribam Construction Of Dc Bungalow

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Jan-2026 Corrigendum 1 Technical Bid 27-Jan-2026
2 03-Feb-2026 Corrigendum No. 3 Date 09-Feb-2026
3 09-Feb-2026 Corrigendum No. 4 Date 13-Feb-2026
4 26-Jan-2026 Corrigendum No. 2 Date 05-Feb-2026
5 20-Feb-2026 Corrigendum No. 6 Date 27-Feb-2026
6 13-Feb-2026 Corrigendum No. 5 Date 20-Feb-2026

BOQ

Name of Work: Infrastructure creation for District Administration of new district Jiribam - Construction of DC Bungalow Jiribam
Sl. No. Item Description
1(SH: Construction of Bungalow)
2Earthwork
3Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
4Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 meters lift upto 1.5 metre.
5Supplying and filling in plinth with sandy soil under floors including watering,ramming, consolidating and dressing complete.
6Cement Concrete Works
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
8Form Works
9Centering and shuttering including strutting, propping etc. and removal of form for:
10a)Foundation, footing, bases of columns etc. and mass concrete
11b) Columns, pillars, posts and struts (square rectangular or polygon in plan).
12c) Lintels, beams, Plinth beams, girders, bressumers and cantilevers.
13d) Suspended floor, roofs, landings, balconies and access platform.
14e) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
15f)Stairs, (excluding landings) except spiral-staircases.
16g)Arches, domes, vaults upto 6m span
17R.C.C. Work
18Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength ; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
19i) All works upto Plinth level.a) Concrete of M-25 grade with minimum cement content of 330Kg/cum
20ii) All works above Plinth level upto floor V Levela) Concrete of M-25 grade with minimum cement content of 330Kg/cum
21Reinforcement for RCC work including straighting, cutting, bending, placing in position and binding all complete. -Thermo-Mechanically Treated bars.
22Brick Works
23Brick work with first class common burnt clay F.P.S. (non-modular) brick in foundation &plinth in cementmortar 1 : 4 ( 1cement : 4 coarse sand).
24Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
25WOOD WORKS
26Providing wood work in frames of doors, windows, clerestorywindows andotherframes wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia. And length (hold fast or dash fastener shall be paid for seperately(a) Local best quality Tolhao
27Providing and fixing panelled or paneled and glazed shutters for doors,windowsand clerestory Windows i/c ISI marked M.S.butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately, all complete as per direction of Engineer-in-charge.(a) Local best qualityTeak wood - 35 mm thick shutters.
28Providing and fixing bright finished brass butt hinges withnecessary screws etc. complete :125x85x5.5 mm (heavy type)
29Providing and fixing ISI marked oxidised M.S. Tower bolts black finished(barrel type ) with screws etc. complete.
30Providing and fixing bright finished steel 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
31Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. complete : a)125mm
32STEEL WORKS
33Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
34Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
35FLOORING
36Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded stone aggregate 20mm nominal size)
37Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
38Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of sizeSize of Tile 600 x 1200 mm
39Marble stone flooring with18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality
40Extra for prefinished nosing to treads of steps of marble stone.
41ROOFING
42Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1Cement : 4 Coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finish neat complete.
43FINISHING
4412 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
4515 mm cement plaster on rough side of single or half brick wall of mix 1 : 4 (1 cement : 4 coarse sand)
46Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
47Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
48Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
49Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. i) Two or more coats on new work-
50Applying priming coat with ready mixedpink or grey primer of approved brand and manufacture on wood work.(Hard and soft wood).
51Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
52Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
53SANITARY INSTALLATIONS
54Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests
55Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
56Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
57Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm
58Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
59Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
60Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
61Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete semi rigid pipe 40 mm
62Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
63WATER SUPPLY
64Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
65a) 32 mm dia pipe
66b) 50 mm dia pipe
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc
68a) 25 mm dia pipe
69Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
70(SH : Construction of Office at DC Bungalow)
71Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
72Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
73Supplying and filling in plinth with sandy soil under floors including watering,ramming, consolidating and dressing complete.
74Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
75Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :- 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
76Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
77Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
78Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
79Centering and shuttering including strutting, propping etc. and removal of form for:
80a) Foundation, footings, bases of columns etc. and mass concrete.
81c) Columns, Pillars, Piers, Abutments, Posts and Struts.
82d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
83Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
84Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
85Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : - Local best quality Uningthou wood
86Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. -b) Local best quality Tolhao wood. 35 mm thick shutters
87Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
88Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
89Providing and fixing bright finished steel 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
90Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :.- 300 x 16 mm
91Providing and fixing ISI marked oxidised M.S. Tower bolts black finished(barrel type ) with screws etc. complete. 250 X 10mm.
92Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. complete : a)125mm
93Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.
94Cement concrete flooring 1:2:4 (1 cement : 2 C/Sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete- 40 mm thick with 20mm nominal size stone aggregate.
95Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of sizeSize of Tile 600 x 1200 mm
96Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
97Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. a) 1.00mm thick with zinc coating not less than 275gm/m2
98Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. A) 0.80mm thick with zinc coating not less than 275gm/m2
99Providing and fixing at all height false ceiling including providingand fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mminterval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng toa flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
100Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.a )Electric resistance or induction butt welded tubes.
101Providing and fixing M.S. round holding down with nuts and wahser plates completes.
10212 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
10315 mm cement plaster on rough side of single or half brick wall of mix 1 : 4 (1 cement : 4 coarse sand)
104Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
105Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
106Applying priming coat with ready mixedpink or grey primer of approved brand and manufacture on wood work.(Hard and soft wood).
107Applying priming coat:-With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:-
108Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
109Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
110Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. i) Two or more coats on new work-
111Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
112Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests
113Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
114Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
115Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
116Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete semi rigid pipe 40 mm
117Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
118Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
119a) 32 mm dia pipe
120Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc
121a) 25 mm dia pipe
122(SH : Construction of Security Barrack at DC Bungalow)
123Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
124Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
125Supplying and filling in plinth with sandy soil under floors including watering,ramming, consolidating and dressing complete.
126Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
127Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :- 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
128Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
129Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
130Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
131Centering and shuttering including strutting, propping etc. and removal of form for:
132a) Foundation, footings, bases of columns etc. and mass concrete.
133c) Columns, Pillars, Piers, Abutments, Posts and Struts.
134d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
135Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
136Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
137Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
138Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : - Local best quality Uningthou wood
139Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. -b) Local best quality Tolhao wood. 35 mm thick shutters
140Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
141Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
142Providing and fixing bright finished steel 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
143Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :.- 300 x 16 mm
144Providing and fixing ISI marked oxidised M.S. Tower bolts black finished(barrel type ) with screws etc. complete. 250 X 10mm.
145Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. complete : a)125mm
146Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.
147Cement concrete flooring 1:2:4 (1 cement : 2 C/Sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete- 40 mm thick with 20mm nominal size stone aggregate.
148Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of sizeSize of Tile 600 x 1200 mm
149Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
150Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. a) 1.00mm thick with zinc coating not less than 275gm/m2
151Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. A) 0.80mm thick with zinc coating not less than 275gm/m2
152Providing and fixing at all height false ceiling including providingand fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mminterval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng toa flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
153Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.a )Electric resistance or induction butt welded tubes.
154Providing and fixing M.S. round holding down with nuts and wahser plates completes.
15512 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
15615 mm cement plaster on rough side of single or half brick wall of mix 1 : 4 (1 cement : 4 coarse sand)
157Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
158Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
159Applying priming coat with ready mixedpink or grey primer of approved brand and manufacture on wood work.(Hard and soft wood).
160Applying priming coat:-With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:-
161Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
162Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
163Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. i) Two or more coats on new work-
164Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
165Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests
166Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
167Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm
168Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
169Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
170Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete semi rigid pipe 40 mm
171Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
172Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
173a) 32 mm dia pipe
174b) 50 mm dia pipe
175Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc
176a) 25 mm dia pipe
177(SH: Construction of Garage for DC Bungalow)
178EARTH WORK.
179Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
180Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
181Supplying and filling in plinth with sandy soil under floors including watering,ramming, consolidating and dressing complete.
182CEMENT CONCRETE WORKS
183Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
184R.C.C. Work
185Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :- 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
186Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
187Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
188Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
189FORM WORKS
190Centering and shuttering including strutting, propping etc. and removal of form for:
191a) Foundation, footings, bases of columns etc. and mass concrete.
192c) Columns, Pillars, Piers, Abutments, Posts and Struts.
193d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
194BRICK WORKS
195Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
196Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
197FLOORING
198Cement concrete flooring 1:2:4 (1 cement : 2 C/Sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete- 40 mm thick with 20mm nominal size stone aggregate.
199ROOFING
200Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. a) 1.00mm thick with zinc coating not less than 275gm/m2
201Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. A) 0.80mm thick with zinc coating not less than 275gm/m2
202Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.a )Electric resistance or induction butt welded tubes.
203Providing and fixing M.S. round holding down with nuts and wahser plates completes.
204FINISHING
20512 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
206Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
207Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
208Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
209PLINTH PROTECTION
210Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
211(SH: Construction of Compound Fencing)
212Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
213Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
214Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
215Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
216Centering and shuttering including strutting, propping etc. and removal of form for:
217a) Foundation, footings, bases of columns etc. and mass concrete.
218d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
219c) Columns, Pillars, Piers, Abutments, Posts and Struts.
220Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :- 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
221Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
222Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
223Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
224Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
22512 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
226Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In grating, frames, guard bar, railing, brackets, gates and similar works.
227Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
228Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
229Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
230(SH: Construction of Security Tower)
231EARTH WORK.
232Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
233Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
234CEMENT CONCRETE WORKS
235Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
236FORM WORKS
237Centering and shuttering including strutting, propping etc. and removal of form for:
238a) Foundation, footings, bases of columns etc. and mass concrete.
239c) Columns, Pillars, Piers, Abutments, Posts and Struts.
240d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
241b) Suspended floors, roofs, landings, balconies and access platform.
242R.C.C. Work
243Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :- 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
244Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
245Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
246Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
247BRICK WORKS
248Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in - Cement mortar 1 : 4 (1 cement : 4 coarse sand)
249STEEL WORKS
250Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.a )Electric resistance or induction butt welded tubes.
251Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.(b) In grating, frames, guard bar, railing, brackets, gates and similar works.
252Providing and fixing M.S. round holding down with nuts and wahser plates completes.
253ROOFING
254Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. a) 1.00mm thick with zinc coating not less than 275gm/m2
255Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. A) 0.80mm thick with zinc coating not less than 275gm/m2
256FINISHING
25712 mm cement plaster 1 : 4 (1 cement : 4 coarse sand)
258Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
259Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
260Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
261(SH: Construction of Retaining Wall)
262Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil.
263Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
264Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC grade M15 (1:2:4) Height upto 5m
265Providing weep holes in brick masonry/ plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and technical specifications
266Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall abd provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.

AI Tender Summary

OUR REF NO 53303111
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-02-2026
Authority
Authority Name Public Works Department
Work Description Tender For Infrastructure Creation For District Administration Of New District Jiribam Construction Of Dc Bungalow
Basic Detail
Tender No EE/PWD/JBM/DCB/2025-26/3
Bidding Type Tender
Location
City jiribam
State Manipur
Key Dates
Publish Date 20 Feb 2026
Submission Date 27 Feb 2026
Open Date 27 Feb 2026
Finance
Tender Value Ref. Documents
Tender Fee 20000
EMD 7.38 Lakhs
Exemption Available
Document List
cd053595-aee2-4111-b59a-fb70f681d554.html
PWD_GCC_2023.pdf
Tendernotice_1.pdf
BOQ.pdf
BOQ_3462.xls
Proforma_of_Schedules.pdf
PWDForm7_8.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 09, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 13, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 05, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 27, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 20, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

cd053595-aee2-4111-b59a-fb70f681d554.html

pdf

PWD_GCC_2023.pdf

pdf

Tendernotice_1.pdf

pdf

BOQ.pdf

xls

BOQ_3462.xls

pdf

Proforma_of_Schedules.pdf

pdf

PWDForm7_8.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders