| 1 | Supply and Installation of Decorative steel pole is made out of mild steel galvanized two profile bottom profile 1000mm x125mmx4.00 mm and upper ribbed profile 2500mmx81mmx3.5mm with cast iron embelishment E8 . the pole has a service window at bottom section with heavy duty four way connector and a MCB mild steel base plate 300x210 mm with four nos mounting holes is fixed with welded with bottom section pole is primer coated and polyurethane painted. Decorative pole shall be installed at desired location including foundation of the pole by making cement concrete foundation of 1:2:3( 1 cement: 3 course sand : 6 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required. make: phillips, bajaj, twinkle & equivalent reputated make as per direction of E/ic (PSR Begam Hazrat Mahal Park) |
| 2 | S/F of ornamental type luminaire 40-45 watt LED post top fitting make of aluminium 534 mm long housing duly powder coated/PU painted with PC/PMMA clear/frosted diffuser with sturdy triple arm MCPCB having high umen LED\"s are mounted on aluminium heat sinks. make: phillips, bajaj, twinkle & equivalent reputated make as per direction of E/ic |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 10 sq. mm 4 core |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 16 sq. mm 4 core |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 25 sq. mm 3-1/2 core |
| 6 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 50 sq. mm 3-1/2 core |
| 7 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 10 sq. mm |
| 8 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 16 sq. mm |
| 9 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 25 sq. mm |
| 10 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 50 sq. mm |
| 11 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect., 40 A SPN |
| 12 | ENCAPSULATED PIPE - IN- PIPE EARTHING Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
| 13 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. (Incoming - 200 Amp TPN 1 No.), Outgoing -63 Amp. TPN-3 Nos., Cat. B. Cubicle Type |
| 14 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only., Cat. B. Cubicle Type |
| 15 | S/B of earth rod 20 mm dia 2.5 mt long including GI wire 7/16 SWG to connected earth rod and earth clamp on pole,3 mt long steel conduit to carry earth wire along the pole complite as per approved of E/Ic. |
| 16 | S/B Supply and laying of 40 mm dia DWC HDPE Pipe ISI Marked along with all accessories like socket, bend, couples etc conforming to IS 14930 part-ii complete with fitting and cutting jointing etc direct in ground (75 cm below ground level) including excavation and refilling the trench but exlcluding sand cushioning and protective covering etc complete as required. |
| 17 | S/B Supply of Feeder Pillar Box, with Aluminium Busbar-4 Strip enclosure CRC & Street powder coated outdoor type aluminium busbar 20 x 4.4 strip, MCB DP 32 m Amp-4 nos 3 pin socket 32 Amp-1 no enclosure size 300 X 350 x 200 mm |
| 18 | Submain in conduit on surface (2.5 sq. mm.) Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, with one number 14 SWG copper earth continuity wire etc, complete in all respect. |
| 19 | Wiring Points in Surface Conduit with PVC insulated 1100 V grade cable, Same as in item 122 B but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 20 | DOWN LIGHT LUMINAIRES Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect., CAT-AAA |
| 21 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve, CAT A |
| 22 | Buy Back of pole damaged pole proper complete of work as per direction of E/Ic. |
| 23 | Dismantling of pole/damaged pole as per PWD schedule 2018 Item No. 601 |
| 24 | FLOOD LIGHT LUMINAIRES Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect., CAT-AAA |
| 25 | Operation and Maintenance of 1st year |
| 26 | Operation and Maintenance of 2nd year |
| 27 | Operation and Maintenance of 3rd year Please Enable Macros to View BoQ information |