| 1 | Earth work in foundation excavation up to 1.5m ramming bottom dressingg sides, back filling and disposal of surplus soil with in a lead of 50m in hard soil |
| 2 | Cement Concrete in foundation and plinth with stone ballast size 40mm including curing and compaction etc in 1:4:8 mix |
| 3 | Brick work in foundation and plinth using bricks of class designation-75 in cm 1:6 |
| 4 | Damp Proof Course with RCC 1:1.5:3 |
| 5 | Brick work In super structure using bricks of class designation 75 CM 1:6 |
| 6 | Reinforcement Cement Concrete work including curing compaction finishing with rendering in cement sand mortar 1:3 and making good and joints excluding cost of centering shuttering and reinforcement in 1:1.5:3 (1cement:1.5course Sand 3-greded stone aggregate 20mm nominal size) |
| 7 | Providing and fabricating reinforcement for RCC work including straightening cutting bending placing in position and binding (including cost of binding wire) in foundation and super structure up to 4.5m height above plinth level hot rolled deformed (IS:1139) cold twisted (IS:1786) Bars |
| 8 | Centering and Shuttering with plywood or steeel sheets including strutting propping bracing both ways wiith wooden members and removal of from |
| 9 | S and F Glazed Tiles on Roof |
| 10 | 20mm thick plaster on new work including curing and racking of joints in CM 1:6 |
| 11 | Providing and Applying white cement based putty over plastered surface to prepare the surface even and smooth complete (PWD BSR-2022- Less 10%) |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding.New work ( Two or more coat incuding base coat of water proofing cement paint) -PWD BSR -2022 - Less 10%) |
| 13 | Wall painting with plastic emulsion paint of required shade including all scaffolding.New work ( Two or more coat incuding base coat of water proofing cement paint) -PWD BSR-2022- Less 10%) |
| 14 | S & F Aluminium Door |
| 15 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting |
| 16 | S and F Wire mesh on Saction windows |
| 17 | S and F Iron Bars on Section Windows |
| 18 | Enamal Painitng on Door and windows |
| 19 | Earth work in filling with ordinary soil |
| 20 | Carrige of earth Lead 01km |
| 21 | cement concrete in floor with stone ballast size 40mm including curing and compaction etc in 1:6:12 |
| 22 | S and F Vertified Tiles on Floor |
| 23 | S and F Glazed Tiles in floor and wall |
| 24 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. (PWD BSR-2022 Less-10%) jhunjhnu/Jalore Red, Black, Choklate 1501 Cm2 to 3600cm2 Tiles |
| 25 | S and F Railing |
| 26 | (Soak Pit)Earth work in foundatio excavation up to 1.5m ramming bottom dressing sides back filling and disposal of surplus soil with in a lead of 50m |
| 27 | Brick work in foundation and plinth using bricks of class designation-75 in CM 1:6 112mm Thick |
| 28 | Brick work in foundation and plinth using bricks of class designation-75 in CM 1:6 |
| 29 | 20mm thick plaster on new work including curing and racking of joints in CM 1:6 |
| 30 | P & L First Class stone slab Roof In |
| 31 | wiring for fan/light point in PVC conduct pipe as per specification |
| 32 | wiring for circuit/submain as per specification - 2x1.5sqmm |
| 33 | S and F PVC Water Storage Tank |
| 34 | S and F Bib Cock |
| 35 | S and F Wash Basin |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (20mm Nominal Size) |
| 37 | S and F Full way valve-20mm |
| 38 | P and L PVC Pipe 110mm |
| 39 | S and F Orisa WC Pan |
| 40 | S and F Half Turn Valve-25mm |
| 41 | Name board Please Enable Macros to View BoQ information |