| 1 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required |
| 2 | 6 Module |
| 3 | 8 Module |
| 4 | 12 Module |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group B |
| 6 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired. |
| 7 | 1 x 1.5 sqmm |
| 8 | 2x 2.5 sqmm |
| 9 | 2 x 4 sqmm |
| 10 | 2 x 6 sqmm |
| 11 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2x 16 + 1 x6 sqmm |
| 12 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVCinsulated copper conductor single core cable and 1.5sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling asrequired. Group B |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired |
| 14 | 5/6 amps switch |
| 15 | 3 pin 5/6 amps socket outlet |
| 16 | 15/16 amps switch |
| 17 | 6 pin 15/16 amp socket outlet |
| 18 | Bell push |
| 19 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 20 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connections etc. as required. |
| 22 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 23 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 24 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 25 | 25 mm |
| 26 | 20 mm |
| 27 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 28 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 29 | Supplying and fixing 63 amps , double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 30 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistancemore than 2 mega ohm, suitable for 230 V 50 HZ , Single phase AC supply , earthing etc complete as reqd |
| 31 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 32 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I.pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 34 | UPTO 35 Sq.mm |
| 35 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 36 | 12 way double door |
| 37 | 8 way double door |
| 38 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole |
| 39 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 40 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hzcomplete i/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No.Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 41 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with IP65 protection and IK09 impact resistance suitable for surface and wall mounting applications., 220-240 V, 50 Hzcomplete i/c all accessories etc directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips, Model endura LED Bulkhead, Cat No.WT202W LED10S CW PSU S3 PC or equivalent model of Thorn/Trilux |
| 42 | Supply, Installation, testing and commissioning of 15 watt, ceiling circular light for commercial grade, surge protection upto 3 kV & wide voltage protection 160-360 V, 50 Hzcomplete i/c all accessories etc. directly on reccess including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing, minimum 110 lm/watt etc. as required. Make philips, Cat No.Astra sleek 15W, WW/NW/CDL or equivalent model of Thorn/Trilux |
| 43 | Supply, Installation, testing and commissioning of pre-wired, 70 watt, Street Light luminaire delivering >100 lumen/watt with PDC housing, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required. Make Philips, Cat No. BRP032 P LED75 CW SLR PSU GR SPD or equivalent model of Thorn/Trilux |
| 44 | Supplying and fixing of 500 mm long over hang single arm bracket made of suitable dia G.I pipe and suitable for 70 mm dia G.I pole including nut bolts etc as reqd. at site (Make Bajaj/paruthi/Surya) |
| 45 | Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No.BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux |
| 46 | Supplying and fixing of angle frame of suitable size(18\"x18\") including excavation and repairing the same etc as reqd. at site |
| 47 | Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade |
| 48 | 4X16 sqmm |
| 49 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |