Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 2 | Demolition ofcement concrete of Sunken portion/EWC/IWCof any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed. |
| 5 | Demolition of brick workbuilt in cement mortor including all quoins,arches,pillars etccomplete all as specified and directed. |
| 6 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortarin floors, aprons etc complete all as specified and directed. |
| 7 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 8 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 9 | Dismantlingstructural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed. |
| 10 | Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 11 | Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed. |
| 12 | Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed |
| 13 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed. |
| 14 | Taking down cement plaster of any descriptionon brick walls or concrete or stone and ceilingsincludingracking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqmeach including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 17 | Dismantling boarding, any description, fixed in any postion with nails or screws complete all as specified and directed. |
| 18 | M&L forLean Cement Concrete (1:5:10) type E-2 using 40mm gradedcrushed stone aggregate as in foundations, filling andmass concrete and filling in Sunken portioncomplete all as specified and directed. |
| 19 | M&L forLean Cement Concrete (1:3:6) type C-0 using 10mm gradedcrushed stone aggregate as infilling back sides of pressed steel framescomplete all as specified and directed. |
| 20 | M&L for brick work built in cement mortar (1:6) with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 21 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work. |
| 22 | S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etcincluding making good jambs portion by providing plaster in CM 1:4 and finishes as per existingcomplete all as specified. |
| 23 | S&F 35 mm thickfactory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etcfor doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed. |
| 24 | S&F factory made35mm thick Plain framed, panelled wooden shutter (any number of panels) of second class hard wood (except Mango)with lock rail and panel 12mm exterior grade wood veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 25 | S&F in replacement Factory Made Box Type Steel Ventilators side /top hung with glazing bars or dovetailed or welded made of ERW tube \"P\"-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No.1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site.4. Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 26 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 27 | S&F 50mmx47mm size solid PVC door framemade out of 5mm plain colour PVC sheetreinforced with MS square tube, complete all as specified shown on drawing and specified and directed. |
| 28 | S&Ffactory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed. |
| 29 | S&F 25mm thickPrelaminated particle board, exterior grade, prelaminated both sides with decorative choicelaminations, flat pressed, single or three layer type with BWP type phenol formaldihide adhesive as in cup board/ ward robe shutters and shelves including 6mm thick teak wood lipping on three sides of shutters and 20mm thick on hanging side fixed with glue and headless mild steel nails and shuuters fixed with screws to timber frame work complete all as specified and directed. |
| 30 | S&F 100mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised andtype C-21 complete all as specified and directed. |
| 31 | S&F 200mm long aluminium anodised barreltower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 32 | S&F 150mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 33 | S&F in repairs 125mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 34 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 35 | S&FFloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover platefixed in floor complete all as specified and directed, |
| 36 | S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed, |
| 37 | S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 38 | S&F in repairs 25mm dia mild steel curtain rods,fancy type, epoxy powder coatedwith and including finials, bubs and brackets, stops and rollers etc. complete all as specified and directed |
| 39 | S&F Stainless Steel WireCloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 40 | S&F in repairs Stainless Steel WireCloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 41 | S&F in repairs 3.15mm dia plain mild steel wire, galvanised class 3 as for mosquito nets and fixing to straining bolts, hooks, eyes, etcincluding straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed. |
| 42 | S&F 3.0mm thick, plainsheet glass, ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 43 | M&L for 75mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 44 | M&L for75mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm gradedcrushed stone aggregate as in sub base of flooring,surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 45 | M&L for25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm gradedcrushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 46 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 47 | M&L for Machine cut kota stone slab 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in vertical surfaces such as skirtings, dados, risers and steps etcincluding rubbing and polishing complete over and including 10mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 48 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality,Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 49 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality,area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etcset and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 50 | M&L for 7mm thick(Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm)Glazed Ceramic Coloured Tiles,in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etcset and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 51 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 52 | M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on anyface of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 53 | M&L for 15mm thick rendering screed bed or bedding layer of cement plaster in cement mortar (1:4) for laying roof tiles complete all as specified and directed. |
| 54 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer on fair furfaces of brick or concrete work on roof terrace for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer\"s instructionsfinished even and fairwithout using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 55 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer or cement plater to the sunken portion, mixed with water proofing complound as per manufacturer\"s instructions finished even and fairwithout using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 56 | M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 57 | M&L for water proofing treatment to sunken floors of Kitchen, toilets, laboratories, bath and WC\"s etc shall be as under :- (i)Application of two components of Acrylic modified Cementitious coating(aa)Clean the RCC Surface with wire brush and chisel out and mortar sticking to Surface(ab)Apply FOSROC NITOPROOF 600 PF (min 0.8mm dft) over a priming coat of NITOPROOF WB Primer or equivalent of ASIAN PAINT/SIKA/BERGER/PIDILITE DR FIXIT(ac) Provide HDPE 1.0mm thick Sheet before laying of any floor finishes. |
| 58 | M&L forOne layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise ofpolymeric membranes respectively and sealed all overlaps and joints as manufacturer\"s instructions. |
| 59 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqmover a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces complete all as specified and directed. |
| 60 | M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed. |
| 61 | M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cementcomplete all as specified and directed. |
| 62 | M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cementcomplete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace. |
| 63 | M&L for 80mm thick average consolidated thicknessmud phuska on flat roof ncluding 25mm thick mud plaster complete all as specified and directed.Note:- Old mud phuska shall notbe re-used. |
| 64 | M&L forpreparing new plastered surfaces of walls anddistempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 01mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 65 | M&L forpreparing new plastered surfaces of walls and distempering withtwo coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed. |
| 66 | M&L for complete removal of existing treatmenton walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed. |
| 67 | M&L for complete removal of existing treatmenton walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 68 | M&L forpreparing new plastered surfaces of ceiling andapplying three coats of lime white wash complete all as specified and directed. |
| 69 | M&L forpreparing old surfacesdecorated plastered or unplasteredsurfaces ofwalls and applying one coat of lime white wash complete all as specified and directed. |
| 70 | M&L forpreparing old plastered surfaces of ceiling andapplying one coat of lime white wash complete all as specified and directed. |
| 71 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed. |
| 72 | M&L for preparation of old wood or wood basedsurfaces of any description, not otherwise described,over 10cm width or girth and applying one coat of synthetic enamel paint over one coat of pink primercomplete all as specified and directed. |
| 73 | M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all asspecified and directed. |
| 74 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floorscompleteall as specified and directed. Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 75 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 76 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 77 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches completeall as specified and directed.Note:- Only Pipe along the centre line shall bemeasured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 78 | S&F 75mm dia PVC (SWR) bends any radiuscomplete all as specified and directed. |
| 79 | S&F 110mm dia PVC (SWR) bends any radiuscomplete all as specified and directed. |
| 80 | S&F 75mm dia PVC (SWR) bends any radius with oval type access doorcomplete all as specified and directed. |
| 81 | S&F 110mm dia PVC (SWR) bends any radius with oval type access doorcomplete all as specified and directed. |
| 82 | S&F 110mm dia PVC (SWR) Branch piece double (double \"Y\") equal or unequalcomplete all as specified and directed. |
| 83 | S&F 75mm dia PVC (SWR)Junction single (single or double\"T\") equal or unequalcomplete all as specified and directed. |
| 84 | S&F 110mm dia PVC (SWR)Junction single (single or double T) equal or unequalcomplete all as specified and directed. |
| 85 | S&F 110mm dia PVC (SWR) vent cowlcomplete all as specified and directed. |
| 86 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 87 | S&F Stack clamps for 110mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed. |
| 88 | S&F Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed. |
| 89 | S&F 20mm dia Unplasticised PVC pipes of pressure rating 10kgf/sqcmfixed to walls,ceilings or in floor etc., any type of pipe complete as specified and directed. |
| 90 | S&F 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 fittingson walls and ceilings or laying in floorscomplete all as specified and directed. |
| 91 | S&F 25mm dia Unplasticised PVC pipes of pressure rating 10kgf/sqcmfixed to walls,ceilings or in floor etc., any type of pipe complete as specified and directed. |
| 92 | S&F 25mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 fittingson walls and ceilings or laying in floorscomplete all as specified and directed. |
| 93 | S&F in repairsTwo Way brass CP Bibcock with wall flange 50 to 65mm long (facilitate to fix the Halth faucet) (Make:Jaquar) CQTNO;23041/FLR 8041N) and Make: CERA catNo:F3002161 /F200216115 mm dia boretype withhandle, screwed down, screwed for iron pipe or famale of quarter turn type complete all as specified and directed. |
| 94 | S&F 15mm bore Bib Taps, long bodyfancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 95 | S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy,with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipecomplete all as specified and directed. |
| 96 | S&F 15mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipescomplete all as specified and directed. |
| 97 | S&F 20mm boreGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipescomplete all as specified and directed. |
| 98 | S&F in repair 15mm bore push tap any colour of PTMT suitable for urinals screwed for iron pipe and fixed(minimum weight 15mm-47 gms) complete all as specified and directed. |
| 99 | S&F in repair 15mm bore dia Bib tap standard of PTMT any colour high pressure screwed for iron pipebut with long body and fixed.(Minimum weight 15mm-120gms complete all as specified and directed. |
| 100 | S&F in repair pressure Jet spray of chromium plated steel for EWC seats with and includingincluding PVC connection and CP fittings complete all as specified and directed. |
| 101 | S&F 32mm bore PVC waste pipe of suitable lengthto waste coupling pipe attached with rubber ring joints/ PVC threaded cup,fixed to waste coupling of sinks / WHBs/urinal of required lengthcomplete all as specified and directed. |
| 102 | S&F 32mm bore Waste fittings of chromium plated brass for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 103 | S&F 15mmPVC connections 450mm long heavy duty with brass nuts adaptors andwashers and rubber gaskets at both ends complete all as specified and directed. |
| 104 | S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling andtaking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 105 | S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling andtaking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 106 | S&F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipecomplete all as specified and directed. |
| 107 | S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting standincluding waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed. |
| 108 | S&F in repairsVitreous China Squatting Pan, \"Orissa pattern\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed. |
| 109 | S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed. |
| 110 | S&F in repairs Vitreous China urinals, half stall (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed. |
| 111 | S&F in repairs 10 litres capacity low level PVC valveless syphonic action typeflushing cistern with inlet ball valve, float and handle including brackets complete all as specified and directed. |
| 112 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed. |
| 113 | S&F in repairs 100 mm dia Chromium plated shower rosewith 125mm long CP arms, with or without swivel joints, including fixing complete to steel pipe or union complete all as specified and directed. |
| 114 | S&F Stainless Steel (AISI-304) Shower drain with Cockroach Trap (450 x 75mm) heavy duty including all fittings andfixed with white cement fixed complete all as specified and directed |
| 115 | S&F in repirs 600mmx450mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed. |
| 116 | S&F in repairs tubular Towel Rail 20mm dia brass chromium plated 600mm long between flangestype \"D\",with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 117 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out completeall as specified and as direcetd. |
| 118 | Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 119 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 120 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 121 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for One light/fan/Bell Pointcontrolled by one single pole one way switch.Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 122 | ditto all as per item No 121 but for One socket outlet on the sameboard controlled by one single pole one way switch |
| 123 | ditto all as per item No 121 but forOne 5 amps socket outlet independentcontrolled by one single pole 5 Amp switch. |
| 124 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed forone 3/5 pin 15 Amps switch socket out let on the independentboard controlled by one single pole one way switch.Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 125 | S&F5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 126 | S&F15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 127 | S&F5/6 AmpSocket outlet 2 in1, 3 pin flush typeISI marked complete all as specified and directed. |
| 128 | S&F15/16 AmpSocket outlet 2 in 1, 3 pin flush typeISI marked complete all as specified and directed. |
| 129 | S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated bodyomplete all as specified and directed. |
| 130 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed. |
| 131 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed. |
| 132 | S&F 300mm sweep Exhaust Fan, steel body AC single Phase. 230Vwith blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts, fixing with nuts and washersand making good in cement mortar (1:4) and finshing surfcae to match with existing surfacescomplete all as specified and directed. |
| 133 | Supply, hoist, fix and connect25 litres capacity electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW , BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed. |
| 134 | S&F LED tube light fitting 1 X 18 Wdecorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient230V,complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part No. LHEXBLP7UN1W018 of Make - Havells or equivalent as specified in Appendix \"B\" of Particular Specfications,complete all as specified and directed.. |
| 135 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 136 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs (Verticle type)fitted wit ABS frame, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar andDin rail,4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 137 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar andDin rail,8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 138 | S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 63Amp, 415 Volts,breaking capacity 16 KA with adjustable thermal and magnetic settings, completeall as specified and directed. |
| 139 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type\"B\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 140 | S&F Miniature Circuit Breaker (MCB) Single Pole(SP) current carrying capacity 40Amp, 240V, breaking capacity 10 KA, type\"B\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 141 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral(SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type\"C\" curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 142 | S&F Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in sheet Metal enclosures complete all as specified and directed. |
| 143 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cablesingle core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 144 | S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cablesingle core for continuous earthing including taking down existing submain wiring and conduits etccomplete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 145 | Supply, lay, test, joint and commission LTXLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of sizecross sectional area 25Sqmm x 4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on polecomplete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 146 | Supply and lay 40mm bore galvanised pipe light grade of ISI marked for passing of cable fixed to poles/walls/laid under floor/ laid in trenches ascable protection complete with and including fittings as required compete all as specified and directed.Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ. |
| 147 | M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid. |
| 148 | Supply and lay cable protection cover withBricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed. |
| 149 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm diagalvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light gradeconnected to main switch board or main control board and20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4)type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-Icomplete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wirefrom top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail