| 1 | Repair of existing street light/Security light of any type or discription, fixed in vertical position with poles/wall/Boundry wall including disconnecting the electric connection, removing from pole/wall/Boundry wall if required, carrying out minor repairs like disconection of wire/cable, detecting and repair of UG cable fault, cleaning of carbon on OH/UG line and replacing starter/fuses,etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioningengaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed. |
| 2 | Note :(i) The un-serviceable items shall be replaced under respective items of relevent schedule as below .(ii) T&P viz tools , Trolly mounted transportation veh with operator, ladder any type are provided by the contractor to the electrician party. (iii) The contractor shall be rectified the street light complaint on priority within the 04 hrs. One complaint shall be considered as one Job.(iv) Everyday one electrician and one helper shall be check all Street light & security light whole the area of 23 Wing(v) All safetyprecaution will be taken by the Electrician/Helper incase of any lapse contractor will be responsible for the same.(vi) Before climbimg on parameter light contractor shall ensure that there is no power supply on parameter fencing by concerned AF Department.(vii) In addition with Tech area/Kaluchak complaints contractor shall attend the compaints of all wing area if there is any emergency or requirement. |
| 3 | S&Fin replacement capacity luminaires 45 watt LED >5700Kwith driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 4 | S&Fin replacement capacity luminaires 60 watt LED >5700Kwith driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 5 | S&Fin replacement capacity luminaires 90 watt LED >5700Kwith driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 6 | S&Fcapacity luminaires 100 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,Surge external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 7 | S&Fcapacity luminaires 120 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 8 | S&Fcapacity luminaires 250 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 9 | S&Fcapacity luminaires 350 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 10 | S&Fcapacity luminaires 500 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 11 | S&FLED aviation light 10 watt, rating voltage 215-240 V including necessary connection with two run of 1.50 sqmm single core unarmoured copper cable from junction box to High raised building/OH Water Tank/Tower etcfixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) All safetyprecaution will be taken by the Electrician incase of any lapse contractor will be responsible for the same. (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. |
| 12 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete confrming to Fe-290 (Gde-E-165) complete all as specified. |
| 13 | M&L for preparing new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enemal paint over red oxide primer. |
| 14 | Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel rope and adjust/repairthe timer, supply and fixing in replacement the contacts lifting mechanism with all accessories as required, complete all as directed by the Engineer-in-Charge. |
| 15 | S&Fin replacement outdoor type Tiranga LED Rope light suitable for 9/11 mtr electric PCC/SteelPole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 16 | S&F single core PVC insulated unshesthed cable copper conductor of size 1.5 sqmm multistranded drawing innon-metalic PVC rigid conduit complete all as specified and directed.(Note;- PVC Conduit will be Measure and paid seperatly as relevent item.) |
| 17 | S&F single core PVC insulated unshesthed cable copper conductor of size 2.5 sqmm multistranded drawing innon-metalic PVC rigid conduit complete all as specified and directed. (Note;- PVC Conduit will be Measureand paid seperatly as relevent item.) |
| 18 | S&F single core PVC insulated unshesthed cable copper conductor of size 10sqmm multistranded for panel wiring complete all as specified and directed. |
| 19 | M&L for mild steel cross arms,(for perimeter fencing ladder stand stud)bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 20 | S&F capacity luminaires 1000 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66, pressure die cast aluminium body, Operating Voltage 140-270 Volts,140Lum/Watt, toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. |
| 21 | S&F in replacementthermoplastic polycarbonate cable junction boxhinged door type of size 200x160x 98 mm for 3 Phase and Nutralincoming cable, 3 Phase and Nutral outgoing cable and single Phase & Nutralconnection for light fitting withaluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed. |
| 22 | S&F Timelite distribution board 63 Amps single Pole/230 Volt with Astronomical time switch consisting of MCB SP 63 Amps -1 No, Timer, Power Contactor 65 Amps TP -01 No complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F in replacement multiblecable service connection PVC boxesweather proof for outdoor installation including fixing accessoriessuitable forCable Size 16/25/35 Sqmm, Box Dimensions as per exsistingcompleteall as spcefied and directed by Engr-in- charge. |
| 24 | S&F Rigid non-metallic PVC conduit 25mm dia (Heavy duty)in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed. |
| 25 | S&FMCB SPN 40Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed. |
| 26 | S&FMCB Single Pole Neutral16/25Amps C Curve25 KA with Sheet metal encloser, complete all as specified and directed. |
| 27 | S&F Sheet metal encloser, DB Two Way complete all as specified and directed. |
| 28 | S&F LED Post top light25W 5700K made in die cast aluminium bottom housing and spun aluminium top reflector with decorative PMMA Opal and clear diffuser and IP65 protection complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F LED Post top light45W 5700K made in die cast aluminium bottom housing and spun aluminium top reflector with decorative PMMA Opal and clear diffuser and IP65 protection complete all as specified and directed by Engr-in-Charge. |
| 30 | S&FLED Gardenlight9 W 5700K made in die cast aluminium alloy spigot and optical grade PMMA diffuser and IP65 protection height not less than 1.2mtr complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F PVC insulated sheathed service wiretwin core 2.5 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 32 | S&F PVC insulated sheathed service wiretwin core 04 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 33 | S&F PVC insulated sheathed service wiretwin core 06 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 34 | S&F PVC insulated sheathed service wiretwin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 35 | Preparation of old painted surface of 9 Mtr. steel tubular poles above the top of PCC coping.Painting of pole from top of coping to a height of 1.5mtr with two coats of synthetic enamel paint in white and sky blue alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paintand to the entiresatisfaction of Engineer-in-Charge complete all as specified and directed |
| 36 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed |
| 37 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 51 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed |
| 38 | M & L for Preparation of old cement based painted surfaces of RCC pole 9 mtr by cleaning of depositedmaterials,and painting withone coat of exterior emulsion weather coat paint of approved make and colour above the top of PCC coping.Painting of pole from top of coping to a height of 1.5mtr with two coats of synthetic enamel paint in white and sky blue alternate strip complete all as specifiedand directed byEngineer-in-Charge |
| 39 | S&Fin replacement ofCircular,LED Post Top light, 45 watt 3000K,& 4500 lumens output & CRI>80, IK 10 with optical grade PC diffuser,Pressure die cost aluminium single body and IP66 , anti corrosive epoxy powder coated, the dia of the light suitable for top ofthe pole dia 60mm complete all as specified and directed. |
| 40 | S&F LED luminaire Post Top light, 45 watt 3000K , With 50000 Hourning hours of maintenance output & 4950 lumens output & CRI>70, IK 08 with aluminium housing . Bajaj CAT Part No BOR NX 45W 30K DO C3 GG S PT or equivalent in Philips/Havells/Wipro makecomplete all as specified . |
| 41 | S&F ofLED TRI colour light 4mtrColumn with die-cast aluminium top with cylindrical opal polycarbonate diffuser deigned for rugged outdoor usage & IP 65 protection, with inbuilt driver & surge protection (int 4kv & ext 10 kv) Polyurethane finish & maintenance output of 50000 burning hours , Lumin output of 5000 lumenscomplete with all nuts & bolts all as specified and directedBajaj CAT Part No BLSLC 50W LED TRI 4Mor equivalent in approved makes With light fitting complete all as specified . Make : |
| 42 | Supply , installation, Commissiong & Testing of outdoorLT feeder pillar compartmentalised design of size not less than 70 x 70 x 25 cm suitable for 440 volt 3 phase 4 wire system made out of 3.15mm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts, and washers etc..complete with mounting accessories including the following components:-(a) Four 30cms long Aluminiumbus bar capacity 160 Amp mounted on epoxy insulators provided with rust proof nuts bolts and washers (b)LED indicating lamps - 3 nos. (Red ,Yellow, Blue)(c ) MCCB 100 Amp 4 Pole 25 KA with adjustablethermal and fixed magnetic setting as a Incomer Complete All as specified and directed. |
| 43 | M&L for PCC 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work i.e road cuttingto achieve fair finishes surfaces, complete alal as specified and directed. |
| 44 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge. |
| 45 | All as per srl item No43 here-in-before but of size 25 Sqmm 3.5 Core. |
| 46 | All as per srl item No 43 here-in-before but of size 35 Sqmm 3.5 Core. |
| 47 | All as per srl item No43 here-in-before but of size 50 Sqmm 3.5 Core. |
| 48 | All as per srl item No43 here-in-before but of size 10 Sqmm 4 Core. |
| 49 | All as per srl item No43 here-in-before but of size 10 Sqmm 2 Core. |
| 50 | All as per srl item No43 here-in-before but of size 6 Sqmm 2 Core. |
| 51 | Taking out carefully manually by excavation of existing LT/HT cable with loops and relaying with DWC pipe/brick the same after repair of cutting the damages / burnt parts of cable and reconnecting its into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i)HT/LT Cable Joint & DWC Pipe/Brick will bemeasured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling. (iii) Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate. |
| 52 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 53 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil |
| 54 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 55 | S&F GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing/garden light/decorative road light and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 56 | All as per srl item No 54here-in-before but of dia 80 mm. |
| 57 | S&Fin repairs ISI mark aluminiumthimblessuitable for under ground LTcables of sizes 16/25 sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same. |
| 58 | All as per srl item No 56here-in-before but of size 35/50 Sqmm |
| 59 | M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed. |
| 60 | Dismantling of interlocking cement concrete (any thickness/size), on floor fixed in cement mortar in single layer complete all as specifed and directed. |
| 61 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60mm thickness , M-35 grade, with grey cement and pigment. Complete all as specified and directed. |
| 62 | All as per srl item No 60 above but except interlocking cement concrete tiles, (Any thickness/size) (old interlocking tiles obtained from srl items No 30, Complete all as specified and directed. |
| 63 | M & L 25 mm thick sand filling under floor/interlocking tiles etc Complete all as specified and directed. |
| 64 | Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 metres where directed at a level not exceeding 1.5 metre above the starting pointcomplete all as specified and directed by Engineer-in-Charge. |
| 65 | M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor finishing foundation filling and mass concrete , complete all as specified and directed. |
| 66 | Supply only LT Insulation tape High quality size minimum 20 mtr long x 2.5 CM width complete. |
| 67 | S&F street lightmounting bracket made out of GI pipe 40 mm dia medium Grade not less than with 1.5 m.long in any shapeand painting with aluminium paint,all as direced by Engr in Charge |
| 68 | S&F solarstreet light luminaire efficacy of 120 lumen/watt and system wattage of 30 watthaving compact and fully integrated design with intelligent features includes a built in solar Panel, lithium Ferro phosphate Battery, charge Controller and Motion sensor including all fixing accessories for existing pole complete all as specified anddireced by Engr in Charge. |
| 69 | S&Fin replacement outdoor type LED Rope (wave AC Rope 60D Strip IP65 50mtr long Rope) bright & even illumination with 270 lm/m light output, warm white colour/Sky blueOperting Voltage 140-270 Volts AC Supply 50Hz supply connection complete all as specified and directed by Engr-in-Charge. |
| 70 | Exacavation for cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge. |
| 71 | Material and labour for LT panel preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel incl door hinges welding and locking knob as per the existing type complete all as specified and directed. |
| 72 | S&F in replacement ofMCCB 160Amps 4 pole 25 KA adjustablethermal and fixed magnetic setting, complete all as specified and directed. |
| 73 | S&Fin replacement ofMCCB 100Amps 4 pole 25 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting,complete all as specified and directed. |
| 74 | S&F in replacement of MCCB 100Amps 4 pole 25 KAadjustablethermal and fixed magnetic setting,complete all as specified and directed. |
| 75 | S&F in replacement of on load change over315 Amp 4 pole complete withwith Sheet metal encloser incl operating handle and dismantling/connection ofexisting cables complete as specified and directed by Engineer-in-Charge. |
| 76 | Servicing and programming street light timer panel of microprocessor based automaticPower Management Unit (PMU) suitable for operation on three phase 4-wire. The PMU shall maintain a constant voltage of 400V AC three-phase for a variable input range of 320-480V AC incl such minor parts as per the existing i.e relay,Controller,timer etc are included in quoted rate Complete all as specified and directed by Engr in Charge. |
| 77 | S&F , in replacement,coils made out of super enameled double paper coated (DPC)copper winding wire of street light timer panel transformers, coils to be repalced as per existing number of turns, gauge, insulation value matching with manufactures design complete all as specified. |
| 78 | SCHEDULE \"A\" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch \"A\" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. |