| 1 | Taking down old unserviceable copper/aluminium point wiring (light, fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc. |
| 2 | Taking down carefully old unserviceable sub main wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. |
| 3 | Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single coreFRLSdrawn into and including non-metallic rigid PVC conduit / PVC Casing Caping suitable size, FRLSwiring,along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roofexcluding Modular Metal flush box / PVC Modular Box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc which shall be measured and paid separately all as specified and directed for :- |
| 4 | (a) One light point or fan/Exhaust fan point controlled by one regulator / one switch |
| 5 | (b)One 3 pin socket outlet 5 amps socket onindependent board with cables 1.5 sq. mm size |
| 6 | (c) One 3 pin socket outlet 5 amps socket on Same Board with other switches, with cables 1.5sq. mm size |
| 7 | (d) One light point controlled by two 2-way switches, with cables 1.5 sq. mm size |
| 8 | (e) One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size |
| 9 | All as per item No. 3 here-in-before but with 4 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 4 sqmm cable as earthing conductor. |
| 10 | Supply and Fix modular socket modular 2/3 pin 6 Aflush type 2 module. |
| 11 | Supply and Fix modular socket modular 2/3 pin 16 Aflush type 2 module. |
| 12 | Supply and fix Modular switch flush type single pole one way 10 A, 240 Volts complete all as specified and as directed including taking down old unserviceable switches. |
| 13 | Supply and fix in repair switch Modular type single pole two way 10 A, 1 Module, 240 Volts including taking down old unserviceable switchandremoving the material for taking credit complete all as specified and as directed. |
| 14 | Supply and fix in repair switch Modular type single pole one way 16 A, 1 Module, 240 Voltsincluding taking down old unserviceable switches andremoving the material for taking credit complete all as specified and as directed |
| 15 | Supply and fixceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed. |
| 16 | Supply and fix call bell Ding dong . |
| 17 | M&L PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep |
| 18 | M&L PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep |
| 19 | Supply and fix in repair Stepped type Modular electronic fan regulator 120W, 2 Module flush type on the existing phenolic laminated sheet etc complete including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 20 | Supply and fix in repair Modular Bell push flush type6 A, 1 Module, 240 Voltsincluding taking down old unserviceable bell push andremoving the material for taking credit complete all as specified and as directed. |
| 21 | S&F Repairs LED light fitting 4feet,1x20w,a trendy wall mounted battern,with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make Crompton Or Wipro, Havells, Philips. Including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 22 | S&F Repairs Energy saving new generation 10W LED IP65 bulkhead luminaries with opal diffuser, Make C&S/ Crompton/Havells/Philips/ Wipro. Including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 23 | Supply and fixing Repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make Crompton Or Wipro, Havells, Philips, including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 24 | Supply and fixing repairs LED luminaries 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 25 | Supply and fixing Repairs round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. .Make : Philips Or equivalent in Wipro/Havells, Crompton, including taking down old unserviceable electronic fan regulator andremoving the material for taking credit all as specified and directed. |
| 26 | S & F modular white cover plate with frame 2 module |
| 27 | S & F modular white cover plate with frame 3 module |
| 28 | S & F modular white cover plate with frame 4 module |
| 29 | S & F modular white cover plate with frame 6 module |
| 30 | S & F modular white cover plate with frame 8 module |
| 31 | S&F ofPVC Modular Gang Box 1/2 Module |
| 32 | S&F ofPVC Modular Gang Box 3 Module |
| 33 | S&F ofPVC Modular Gang Box 4 Module |
| 34 | S&F ofPVC Modular Gang Box 6/8 Module |
| 35 | Supply and fix Angle Lamp holderPVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed. |
| 36 | Supply Only LED 9/12/18 watt bulb. Make:- Crompton,Havells,Wipro |
| 37 | S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified. |
| 38 | M&L for sub main wiring with 4 runs of 10 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitable PVC conduit/Casing Caping all as specified. |
| 39 | M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitable PVC conduit/Casing Caping all as specified. |
| 40 | M&L for sub main wiring with 2 runs of 2.5 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 2.5 sqmm copper FRLS cable as earth lead in suitable PVC conduit all as specified. |
| 41 | S&F 2.5 Sqmm PVC round sheathed (flexible)industrial cable 1100 volts grade Cable with copper conductor |
| 42 | Supply and fix Sheet metal enclosures with socket plug top and MCB SP 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclosures with socket plug top complete all as specified and directed. |
| 43 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 44 | (i) SP 6 To 32 AMP |
| 45 | (ii) SPN 40 to 63 AMP |
| 46 | S & F RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters. Complete all as specified and as directed by Engr-in-charge. Make:- Legrand Cat Part No 4113 35. or equivalent Havells/L&T/C&S. |
| 47 | Supply and fixIsolator SP 63 Amp, 240 Volts completeall as specified and as directed. |
| 48 | Supply and fixIsolator TP 63 Amp, 240 Volts completeall as specified and as directed. |
| 49 | Supply and fixIsolator TPN 63 Amp, 415 Volts completeall as specified and as directed. |
| 50 | Supply and Fix MCCB 4 Pole .415 V. fixed type, 63 Amps with breaking capacity 16 KA |
| 51 | Supply and Fix MCCB 4 Pole .415 V. fixed type, 100 Amps with breaking capacity 16 KA |
| 52 | Supply only condenser 2.5 MFD (for Ceiling Fan) complete all as specified and directed.(Make : Usha/Keltran/uptran) |
| 53 | Fixing only after repair fan regulator supply and connecting |
| 54 | Supply and fix in repair wall mounted fan sweep 400mm,RPM 1300, single phase 220V , Oscilation angle in Degree 90 complete al as specified Engineer in Charge. |
| 55 | Taking down after disconnection ofelectrical connections etc of the existing wall mounting fan of any size of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge |
| 56 | Rewinding of wall mounting fan of any type and make,stator coil with super enameled copper winding wire of appropriate gauge / quantity ofburnt stator coil. |
| 57 | Supply and fix only ball bearing |
| 58 | Supply and fix only capacitor of 4 mfd forwall mounting fan |
| 59 | Supply and fix only condenser holder |
| 60 | Scrubbing / removing the existing paints from the wall mounting fan 400 mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer. |
| 61 | Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers |
| 62 | Taking down after disconnection ofelectrical connections etc of the existing Exhaust fan 300mm / 450mm sweep of any make and checking for fault and fixingback in position after carrying out all repair works including connecting up complete all as specified and directed by Engineer in Charge |
| 63 | Rewinding of exhaust fan250/300mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity ofburnt stator coil complete all as specified and directed by Engineer in Charge |
| 64 | Rewinding of exhaust fan450mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity ofburnt stator coil. |
| 65 | Supply and fix only ball bearing for250/300/450mm sweepExhaust fan. . |
| 66 | Supply and fix only suitable capacitor for250/300/450mm sweepExhaust fan. |
| 67 | Scrubbing / removing the existing paints from the exhaust fan 300/ 450mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer. |
| 68 | Supply and fix only new fan blades set for 250/300 mm sweep fan. |
| 69 | Supply and fix only new fan Blades forexhaust fan of 380 to 450mm sweep. |
| 70 | Fixing only exhaust fan after repair and connecting up including provision of cable from ceiling rose/connector to fan. |
| 71 | Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed. |
| 72 | Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 73 | Taking down after disconnection ofelectrical connections etc of the existing ceiling fan 1200mm sweep of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge |
| 74 | Rewinding of ceiling fan 1200mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity ofburnt stator coil. |
| 75 | Supply and fix only ball bearing for ceiling fan 1200mm sweep. |
| 76 | Supply and fix only condenser holder. |
| 77 | Supply and fix new rubber shackle with bolt nut split pin complete. |
| 78 | Supply and fix Ceiling fan Rod any size |
| 79 | M&L Scrubbing / removing the existing paints from the ceiling fan 1200 mm sweep and painting Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed by Engineer in Charge. |
| 80 | Hanging only ceiling fan after repair and connecting up including provision of cable from ceiling rose or connector to fan. |
| 81 | Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 3 phase 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 82 | Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover single phase230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 83 | Taking out the voltage stabilizer of any make and ofcapacity 4/5 KVA from site and transporting to servicingcentre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Chargecomplete all as specified and directed. |
| 84 | Dismantling the burnt out transformer fromthe 5 KVA capacitystabilizer of any make and rewinding the same with supper enamelled copper wire including provision of all materials and refixing into the stabilizer and testing to the entire satisfaction of Engineer-in-Chargeand testing complete all as specified and directed. |
| 85 | All as per Sl item No 84.00 herein before but capacity 4 KVA. |
| 86 | Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed. |
| 87 | All as per Sl item No 86.00 here-in- before but PCB (printed circuit board). |
| 88 | All as per Sl item No 86.00 here-in -before but 3 core flexible card 2.5 Sqmm. |
| 89 | All as per Sl item No 86.00 here-in- before but indicating lamp. |
| 90 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. |
| 91 | Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed.Notes :- Replacement ofspareswill be measured and paid for separately under respective items of the schedule here-in-after as supply only. |
| 92 | Supply and Fixonly new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed. |
| 93 | Supply and fix only thermostat suitable for storage type water heater complete all as specified and directed. |
| 94 | Supply and fix only Pressure release valve 15mm dia suitable for geyser complete all as specified and directed. |
| 95 | Supply and only Air release valve 15mm dia suitable for geyser complete all as specified and directed. |
| 96 | Supply and fix onlyApparatus plate assembly suitable to fix thermostate, heating elements as ofgeyser and nuts etc complete all as specified and directed. |
| 97 | Supply and fix only Fusible plug |
| 98 | Anchor bolt for fixing Heater |