| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) not exc 1.50m depthincluding getting out all kind of soil (soft/loose soil or hard/dense soil) and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge complete all as specified and as directed. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) exc 1.50m depth but n exc 3.00m depth including getting out all kind of soil (soft/loose soil or hard/dense soil) and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge complete all as specified and as directed. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) exc 3.0m depth but n exc 4.50m depth including getting out ordinary rock (soft disintregated rock) and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge complete all as specified and as directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 5 | M&L for 150mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 6 | M&L for cement concrete (1:4:8) type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | M&L for Brickwork with old size subclass ‘B’ burnt bricks, straight or curved on plan n exc 6m mean radius built in built in cement mortar (1:4) complete all as specified and as directed. |
| 8 | M&L for rendering 15mm thick plaster in cement mortar (1:4) onfaces of brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 9 | Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and as directed. |
| 10 | M&L for Loose filling with broken burnt brick aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed. |
| 11 | M&L for Loose filling with stone aggregates of gauge 40 mm in soakage pits, soakage wells complete all as specified and as directed. |
| 12 | M&L for Loose filling with stone aggregates of gauge 20mm in soakage pits, soakage wells complete all as specified and as directed. |
| 13 | M&L for sand filling under floors or in foundations or soak pit/ reacharge pit including watering and consolidation complete all as specified and as directed. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 15 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 16 | M&L for Reinforced cement concrete (nominal mix)1:1.5:3 Type A1 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 17 | M&L for Providing1:2:4 Type B1 (20mm graded aggregate) precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed. |
| 18 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) fair finished surfaces of concrete complete all as specified and as directed. |
| 19 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide fair finished surfaces of concrete complete all as specified and as directed. |
| 20 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 21 | M&L for 150mm dia UPVC Pipes (SCH-40) with 10mm dia hole 5cm in both directions as perforated for water reacharge on ground, single socketed with all joints, in any length with rubber ring joints, laid in trenches, bores, pits or in floors complete all as specified and as directed. |
| 22 | M&L for 6000 Ltrs capacity triple layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 23 | Arboriculture(Item No 24 to 39) |
| 24 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 25 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 26 | Removing excavated material exc. 250 m but not exceeding 500m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 27 | Trees : M&L for digging of pits, including excavationand removal of excavated soil, debris weeds/roots etc, refilling with good garden soil & cattle manure in the ratio 4:1, provision of Anti Termite Treatment at plantation time, Supply & Planting of approved spacis as under of minimum 2\" to 4\" height trees, plants approved and directed by GE. |
| 28 | Ixore (Red & yellow) |
| 29 | Golden Cypress |
| 30 | Lush Green Ficus |
| 31 | Ravenala Madascariensis |
| 32 | Gerbera Different colour |
| 33 | LAWN:- M&L for Surface excavation n. exc 30cm deep and averaging 15cm deep in any type of ground/soil, Provn of Anti Termite Treatment at the rate of 5.00 ltr per sqm (Ratio, Water 19ltr : ATT Chemical1ltr), refilling with 10cm thick good garden soil & cattle manure in the ratio 4:1, mixing, levelling, removing & conveying unwanted stuff to a distance exc. 150m and not exc. 200m,and supplying and planting of approved carpet grass and maintaing till well estabilshed by watering, weeding, clipping if necessary etc. all as approved & directed byEngr-in-Charge/GE. |
| 34 | HEDGES:- M&L for Surface excavation n. exc 30cm deep and averaging 15cm deep in any type of ground/soil, preparatory to clipad hedge, (Golden Durenta), removing & conveying unwanted stuff to a distance exc. 150m and not exc. 200m, filling fresh garden soil & manure in excavated area in 4:1 proporion to a height/depth of 10cm & width 0.50m, mixing garden soil &maure thoroughlywell levelling watering on previous night , planting Golden Durenta Hedging, cutting of required species in two rows ht not less than 0.10m (distance of two rows shall be 0.30m & distance between two plants 0.15m) and maintaing till well estabilshed by watering, weeding, clipping if necessary etc. complete all as specified & directed by Engg-in-charge /GE. |
| 35 | S&F 32mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and as directed. |
| 36 | S&F 25mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and as directed. |
| 37 | S&F 20mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and as directed. |
| 38 | S&F for 15mm bore High density polyethylene drip pipes (HDPE) of pressure rating 6 kgf/cm2 laid on ground complete all as specified and as directed. |
| 39 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 32mm bore pipe complete all as specified and as directed. |
| 40 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 25mm bore pipe complete all as specified and as directed. |
| 41 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 20mm bore pipe complete all as specified and as directed. |
| 42 | S&F sprinkler cast copper alloy outlet threaded for 20mm bore GI pipe complete all as specified and as directed. |
| 43 | Making connection of PP-R distribution branch with GI/CI main of following sizes 25 to 100mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and as directed. |
| 44 | NOTE:(a)Temporary arrangements like T&P, PVC pipes, fittings, sprinklers, cutting and making connection on existing line and all other required accessories of any description as directed by Engr-in-charge, to supply of water/ watering to plants/ tress/ lawn/ grass on daily basis to keep live them, shall be deemed to be included in quoted rates by the contractor upto maintanance period of the contract. No extra amount to be paid on this account.(b) During this period of 12 months any plant, shurbs, grass etc is found dead, not true to name or size as specified or not in satisfactory growth plant of approved size and shape shall be replaced by the contractor without any extra cost to govt. (c) Supply and application of manure, sweet earth, sand, ATT chemical and pesticides, fertilizers etc are included in the quoted unit rate during maintenance period. |