| 1 | Taking down old unserviceable copper/aluminium point wiring (light,fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc. |
| 2 | Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. |
| 3 | Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single coreFRLSdrawn into and including non-metallic rigid PVC conduit of 20 mm dia,concealed FRLSwiring,along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roofexcluding Modular Metal flush box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc witch shall be measured and paid separately all as specified and directed for :- |
| 4 | (a) One light point controlled by one switch |
| 5 | (b) One Ceiling fan/Exhaust fan point controlled by one regulator / switch. |
| 6 | (c)One 3 pin socket outlet 5 amps socket onindependent board. |
| 7 | (d) One 3 pin socket outlet 5 amps socket on Same Board. |
| 8 | (e) One light point controlled by two Nosof two way switches. |
| 9 | (f) One bell/buzzer point controlled by one push button. |
| 10 | All as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor. |
| 11 | S&F Modular Socket outlet 2 in 1, 3 pin, 6A 2 Module complete all as specified and as directed. |
| 12 | Supply and fix Modular switch flush type single pole one way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches. |
| 13 | Supply and fix Modular switch flush type single pole two way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches. |
| 14 | Supply and fix switch Socketcombination 2 in 1,6 Amps Flush type 3 module 240 Voltscomplete all as specified and as directed. |
| 15 | Supply and fix switch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 3 Module 240 Voltscomplete all as specified and as directed. |
| 16 | Supply and fixceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed. |
| 17 | Supply and fix call bell Ding dong . |
| 18 | Supply and fixStep type electronic Modular fan regulator flush type2 Module completeall as specified and as directed. |
| 19 | S & F modular white cover plate with frame 3 module |
| 20 | S & F modular white cover plate with frame 6 module |
| 21 | S & F modular white cover plate with frame 8 module |
| 22 | S&F ofModular Metal flush box 3 Module |
| 23 | S&F of Modular Metal flush box 6/8 Module |
| 24 | Supply and fix Lamp holderPVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed. |
| 25 | S & F in repair LED light fitting 4feet,1x20w,a trendy wall mounted battern,with extrunded aluminium housing,with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make C&S ELECTRICOr Crompton,Cat Part NoLTTB4F20WLED/W |
| 26 | S&F in repair Energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser,Cat Part No SIRIUS/10W,Make C&S/ Cromption/Havells/philips. |
| 27 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.Make C&S Electric Or Crompton Cat Part N0:TTB2F10WLED/W |
| 28 | Supply and fixing in repairLED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 29 | Supply and fixing in repair LED 7/9 watt bulb |
| 30 | Supply and fixing in repair LED DRIVER 35/40 watt suitable for 2 x 2 Recess type fittings |
| 31 | S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified. |
| 32 | M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitanle PVC conduit all as specified. |
| 33 | Supply and fix Sheet metal enclousers with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed. |
| 34 | Supply and fix in repairMCCBthree pole 415 volts 50 Hz ,63 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand) |
| 35 | S&F in repair Double Door Vertical TPN Distribution Box4 way complete in SS enclosurewith 200 amps rated busbar.Make : Standard /Lagrant/Havells/L&T or equalent |
| 36 | S&F in repair MCB DB SPN 8 way complete in SS enclosure double door type with 200 amps rated busbar. |
| 37 | Supply and fixing repair amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 38 | (i) SP 6 To 32 AMP |
| 39 | (ii) SPN 32 AMP |
| 40 | S & F repair RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters. Complete all as specified and as directed by Engr-in-charge.Make:- Legrand Cat Part No 4113 35. or equalent Havells/L&T/C&S. |
| 41 | Supply and fix in repairIsolator TPN 40 Amp completeall as specified and as directed. |
| 42 | Supply and fix in repairIsolator TPN 63 Amp completeall as specified and as directed. |
| 43 | Supply only condenser 2.5 MFD complete all as specified and directed.(Make : Usha/Keltran/uptran) |
| 44 | Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed. |
| 45 | Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed.Notes :- Replacement ofspareswill be measured and paid for separately under respective items of the schedule here-in-after as supply only. |
| 46 | Supply and Fixonly new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed. |
| 47 | Supply and fix only thermostat suitable for storage type water heater complete all as specified and directed. |
| 48 | Supply and only Air release valve 15mm dia suitable for geyser complete all as specified and directed. |
| 49 | Supply and fix only Non return valve 15mm dia suitable for geyser complete all as specified and directed. |
| 50 | Supply and fix onlyApparatus plate assembly suitable to fix thermostate, heating elements as ofgeyser and nuts etc complete all as specified and directed. |
| 51 | Taking down defective unserviceable meter andSupply and fix electronic meters temper proofLCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH , Note old defective meter will be deposited in MES store |