| Sl. No. | Item Description |
| 1 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed.Note- For item No 1 to 8, Necessary T&P item required at site for repair of Street Light/High Mast light fittings is deemed to be included in quoted rate. |
| 2 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 6300 lm and system wattage not less than 45W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. |
| 3 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 8400 lm and system wattage not less than 60W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. |
| 4 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 12600 lm and system wattage not less than 90W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. |
| 5 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 8400 lumens and minimum system wattage of 70 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered with ab warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting upto 12 metre height from the normal ground level complete all as specified and as directed. |
| 6 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 12000 lumens and minimum system wattage of 100 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered with ab warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting from High mast poleupto 20 metre height from the normal ground level complete all as specified and as directed. |
| 7 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 14500 lumens and minimum system wattage of 120 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered with a warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting from High mast poleupto 20 metre height from the normal ground level complete all as specified and as directed. |
| 8 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 25000 lumens and minimum system wattage of 200 Watts/210Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered with a warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting upto 12 metre height from the normal ground level complete all as specified and as directed. |
| 9 | S&F New generation LED post top lantern, 15/20 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. |
| 10 | S&F New generation LED post top lantern, 35/40 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. |
| 11 | S&F in repairs,LED bollard light 10W IP65 having step/cylindrical profile aesthetically designed luminaires for outdoor including excavation ,PCC work ,nut and bolt ,proper electrical connection required for fixing complete all as specified and as directed. |
| 12 | S&F in repairs,MCBs, SP 6 to 32 Amps, 10 KA, \"B\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 13 | S&F in repairs, SMC kiosks box/ PVC Junction box for pole suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one No. MCB 10 Amps, SP having size 350mmx270mmx200mm complete including flat iron clamp and all making fixing arrangement with pole complete all as specified and as directed. |
| 14 | M&L for Flexible cable of size 1.5 Sqmm 3 core with multistranded copper conductor FR round 1100 Volts grade heavy duty cable PVC insulated in street light connection from pole junction box at bottom to street light fittings by making two holes for inserting cable including taking down old cable complete all as specified and as directed. |
| 15 | S&F GI bracket, pipe of size 32 mm dia light grade of 1.2 metre long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedon PCC & Steel poles/on wall surfaces and including suitable fabricate MS flat ironclamps of 40X6 mm thick-02 Nossuitable for fixing any place of poles with nuts, bolts & washers or grouting on wall etc and painting with one coat of aluminium paint over a coat of red oxide primer Including taking down old one complete all as specified and as directed. |
| 16 | Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 20 watts rating, LED type with solar panel of 30 watts, LED power 12 watts,Battery capacity-14AH, Lumen more than 1500 Lm, emitting colour cool white, 5700K with over charge device and backup for 08-10 hours of size 450x383x55 MM complete fixed on wall/existing pole of any height ( 6M max from GL)complete all as specified and as directed. |
| 17 | S&F 80mm dia GI pipe (medium grade) with all fittings for mounting of solar street light with excavation, PCC work if required including dismantling of old one complete all as specified and as directed.Note: Excavationand PCC work will be deemed to included in quoted rate. |
| 18 | Supply, Installation, testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors and an advances micro controller suitable for outdoor use having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, High voltage trip and auto reset having specification 415 Volts, 50 Hz complete with all connected accessories of rating 12 KW 3 phase, current range 40 Amps including taking out old unserviceable timer switch complete all as specified and as directed. |
| 19 | M & L for supply, erection and commissioning ofsteel tubular swaged poles simple/decorative type complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type LT type 410 SP-31, (9m long)including two coat of synthetic emulsion paint upto 1.2 metre high in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on polewithexcavation, earth work, PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation and coping of poles with PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) including dismantling of old pole complete all specified and as directed. Note :- Excavation, earth work and concrete work will be measured seperately under respective item. |
| 20 | M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminuum paint over a coat of red oxide primer including dismantling of old cross arms complete all as specified and as directed. |
| 21 | M & L for PCC 1:4:8Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 22 | M & L for PCC 1:2:4, type B1 (using 20 mm gradedcrushed stone aggregate) as in benching and coping, pole coping,cills, hold fasts, fixing of post, water trough etc. includingnecessary formwork (straight or curved) complete all as specified and as directed. |
| 23 | M&L for preparation of newly plastered surface or concrete (Pole coping) exceeding 10 cm width or girth and applying two coats of plastic emulsion paints complete all as specified and as directed. |
| 24 | M & L for preparation of old painted surface of steel tubular pole of 9 metre long swaged pole by removing all dirt, dust, corrosion etc and apply two coat of synthetic emulsion paint upto 1.2 metre hight in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on pole including writing of identification Nos,etc complete all as specified and as directed. |
| 25 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 26 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 27 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 28 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 29 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 2 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 30 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 31 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 32 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed.Note: Punned thickness of sand cushioning will be measured and paid. |
| 33 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable forprotection of LT cable complete all as specified and as directed. |
| 34 | Relaying of old serviceable bricks for cable protection obtain from taking out of old cable complete all as specified and as directed. |
| 35 | M& L for manual boring under roads/hard standing using required T&P without disturbing the top surface of the road, inserting GI pipe n exc 100 mm dia for cable protection complete all as specified and as directed. Note : - GI pipe will be measured & paid separately. |
| 36 | Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 750mmX750mmX300 mm (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators. The panel shall be dust and vermin proof, protection class (IP-54) in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work 40 mm x 40 mm x 5mm thick and 450 mm long, front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrument chamber with RYB indicator LED lamps. The scope of work also comprising of the following: - (A) Aluminium Bus bar chamber rating:300 Amps, TPN, 415V (B) Incoming MCCB rating: 100 Amps, 4P, 10 KA - 01NOTE: (i)Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300mmx300mmx2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outgoing connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate. |
| 37 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. |
| 38 | M & Lfor Air termination, single pointed, aluminium rod 12mm dia and 300mm long to be fixed on horizontal lightning conductor with suitable fixing arrangement including taking down old one complete all as specified and as directed. |
| 39 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block to test point junction box including dismantling of old terminal block complete all as specified and as directed. |
| 40 | S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground fixed on epoxy based moulded insulator, drilling two Nos holes at each joint, one set of lead washers between strips two sets GI nut, bolt, washers gutties, screws etc as required including dismantling of old strip of any description complete all as specified and as directed.Note : Epoxy base moulded insulator, nut, bolt will be deemed to included in quotaed rate. |
| 41 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mmX4mm galvanised iron strip complete all as specified and as directed. |
| 42 | Cutting & trimming of tree branches any girth and sizetouching to overhead lines ,panel area, near street light poles and cleaning the distance 3.0 mtr both sides of overhead line with in a gap of span upto 50 mtrs each depositing the same for cleaning the site complete all as specified and as directed. |
| 43 | M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to GI strip 24mmx4mm upto 7.5 metre by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe from earth electrode up to test point/connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:2:4) type B1 (using 20mm graded crushed stoneaggregate), excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion completeall as specified and shown on plate No 3 of SSR Part-I 2009 including dismantling of old earthingcomplete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail