| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | a)1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | b) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 5 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 7 | a)First Class Countrywood |
| 8 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) |
| 9 | First Class wood 35 mm thick shutters |
| 10 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 11 | a)First class country wood. |
| 12 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 13 | First Class Country wooda)30 mm thick |
| 14 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 15 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 16 | 300x16 mm |
| 17 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : . |
| 18 | a)300x10 mm |
| 19 | b) 100x10 mm |
| 20 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 21 | a)125 mm |
| 22 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. |
| 23 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. |
| 24 | a)30 mm thick plain PVC door shutters. |
| 25 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes. |
| 26 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.40 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 27 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 28 | \"Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of fibre plug and 2\" stainless steel screws , excluding the cost of scaffolding etc. complete. As per the direction of Engineer in charge.(a) 160mm |
| 29 | b) 110mm |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 31 | Two or more coats on new work. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 33 | One or more coats on old work. |
| 34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : |
| 35 | Old work (one or more coats applied @ 0.83 ltr/10 sqm). . |
| 36 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 37 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 38 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 39 | The waterproofing work for the existing roofs shall be carried out as detailed below: (a)The roof area , parapets etc is thoroughly cleaned and surface area shall befree from dust, loose particles, oil, grease, or any other contaminants etc.(b)Applyingthe first coat as a primer, prepared by mixing Brushbond Roof Guard high build fibre reinforced acrylic water proofing coatings for existing roofsor equivalent with clean water in the ratio of 1:1. The primer shall be applied uniformly over the prepared surface. (C) After the priming coat has completely dried, apply the second coat of Brushbond Roof Guard or equivalent directly on the surface as the finishing waterproofing coat.The entire application shall be carried out strictly in accordance with the manufacturer’s specifications and instructions and as per the direction of Engineer in Charge.. |
| 40 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 41 | Of area 3 sq. metres and below |
| 42 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 43 | Of area 3 sq. metres and below |
| 44 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 45 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 46 | Kitchen sink with drain board510x1040 mm bowl depth 250 mm. |
| 47 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 48 | Providing and fixing PVC , low level flushingcistern with manually controlled device (Handle lever ) conforming to IS 7231 with all fittings and fixtures complete. |
| 49 | 10 litre (full flush) capacity-white |
| 50 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 51 | Flexible pipe 32 mm dia |
| 52 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 53 | Rectangular shape 453x357mm |
| 54 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 55 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 56 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 57 | 15 mm nominal bore. |
| 58 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 59 | 15mm nominal bore |
| 60 | Providing and fixing PTMT grating of approved quality and colour. Circular type. |
| 61 | 100 mm nominal dia. |
| 62 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 63 | 100 mm diameter |
| 64 | Removingcompletely all plants/saplings with roots growing on buildingsideat all levels,spouts,khurras,canopy chajjas roof area including application of herbicide to prevent the regrowth etc including disposal of rubbish to the dumpimg ground within a distance of 50m |
| 65 | Taking out existing wooden/pvc door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 66 | Taking out existing wooden window/ventilator shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 67 | Providing and Fixing PVC Floor trap ( including Grating ) of self cleansing design including jointing with PVC Pipes etc. complete |
| 68 | PVC Floor trap 100x75mm |
| 69 | Providing and fixing PVCpipes ofpressure class of 10 kg/Sq.cm completefittings and clamps including cutting and making good the walls etc complete( Internal work ) (a) 20mm outer dia |
| 70 | (b)25mm outer dia |
| 71 | (C)32mm outer dia |
| 72 | Providing and fixing UPVC plastic ball valve of approved brand andquality etc complete as per the direction ofEngineer in Charge. |
| 73 | 20 mm nominal bore |
| 74 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 75 | 30 cm length 15 mm nominal bore |
| 76 | Providing and fixing pvc water tank covers tothe existing pvc water tank afterremoving the damaged covers etc complete as per the direction of Engineer in charge. |
| 77 | Providing and fixing unplasticisedPVCwaste water pipes of pressure class 4Kg/ Sqcm conforming to IS: 13592 including jointing with solvent cement solution . |
| 78 | a)110mm dia |
| 79 | a)75mm dia |
| 80 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 81 | i)Bend 87.5°a)75 mm bend |
| 82 | b) 110 mm bend |
| 83 | ii)Door Benda) 110 mm Doorbend |
| 84 | b) 75 mmDoor bend bend |
| 85 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 86 | a) 50 mm average thicknes |
| 87 | b) 25 mm average thickness |
| 88 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 89 | a) Bars upto 12 mm diameter |
| 90 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 91 | a) SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 92 | b) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 93 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note:Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 94 | a) 12 mm average thickness. |
| 95 | b) 25 mm average thickness in 2 layers. |
| 96 | Credit for takingpossession and disposal of unservicable materials |
| 97 | a) Door shutters with frames |