Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations/laying of cables etc and getting out in soft/loose soil complete all as specified and directed by Engr in Charge. |
| 2 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 mtr but not exceeding3.0 mtr in depth and getting outhard /dence soil and making good surface complete all as specified and directed by Engr in Charge. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr in Charge. |
| 4 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr in Charge. |
| 5 | Supply & laying DWC HDPE Cable duct pipe of size 63 mm bore confirming to IS :16205 Part 24N 450for laying of LT cables etc complete with all accessorieslaid in trenches suitable for cable protection complete all as specified and directed. |
| 6 | Supply & laying DWC HDPE Cable duct pipe of size 110 mm bore confirming to IS :16205 Part 24N 450for laying of LT cables etc complete with all accessorieslaid in trenches complete all as specified and directed. |
| 7 | Supply, Laying and testing in replacement LT UG cable of size 120sqmm 3.5 core,XLPE insulated, PVC Sheathed ,ISI marked ,earthed system , armoured heavy duty ,electric cable with aluminium conductor,1100 Volts grade in trenches/wall/floor/pole complete and making connection including suitable size aluminium lugs all as specified and directed by Engineer in charge including dismantling and taking out of existing cableNote : Excavation and earth work shall be measured and paid separately. |
| 8 | All as per serial item No 7 but 95 Sqmm 3.5 core |
| 9 | All as per serial item No 7 but 70 Sqmm 3.5 core |
| 10 | All as per serial item No 7 but 50 Sqmm 3.5 core |
| 11 | All as per serial item No 7 but 35 Sqmm 3.5 core |
| 12 | All as per serial item No 7 but 25 Sqmm 3.5 core |
| 13 | All as per serial item No 7 but 16 Sqmm 4 core |
| 14 | All as per serial item No 7 but 10 Sqmm 4 core |
| 15 | All as per serial item No 7 but 10 Sqmm 2 core |
| 16 | S & F in replacementStraight through cable jointing kit,heat shrinkablefor 1.1 KV grade XLPE cable of size 4 core 10 sqmm to 4 core 16 sqmm with jointing material and accessories and testing after jointing completeall as specified and directed. |
| 17 | All as per serial item No 16 but 25 to 50 sqmm 3.5 core |
| 18 | All as per serial item No 16 but 70 to 120 sqmm 3.5 core |
| 19 | S&F in replacement galvanised iron, 80 mm boretubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including taking out old unserviceable pipe complete all as specified and directed. |
| 20 | S&F in replacement galvanised iron50 mm boretubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including taking out old unserviceable pipe complete all as specified and directed. |
| 21 | S&F in replacement galvanised iron 40 mm bore tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including taking out old unserviceable pipe complete all as specified and directed. |
| 22 | M&L for cutting existing road/hard standing surfaces to a depth 60 cm and 50 cm width and getting out for laying underground pipe including returning filling in, watering well ramming in layers not exceeding 25cm in soil and filling the trench topwith 15cm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) and making good the disturbed surface complete all as specified and as directed. |
| 23 | Dismantling of ACSR or AAC conductors/Guard wire of any size and any description from any heights/ poles or any location, complete all as specified and as directed. |
| 24 | Dismantling and taking down cross-arms of M.S. channel or angle sections with nuts, bolts ,washers etc complete all as specified and directd. |
| 25 | Dismantling Insulators of any type/shape all as specified and directed. |
| 26 | Dismantling ofLT stay Assembly all as specified and directed. |
| 27 | M&L for Supply and installation,Over head, aluminium conductor, steel reinforced, weasel, including making connections and fixing on poles with all necessary arrangements, complete all as specified and as directed by Engineer-In-Charge.Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc. |
| 28 | S&F in replacement forPin type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 65 mm dia and 100 mmheightISI marked complete all as specified and directed by Engr in charge. |
| 29 | M&L for shackle type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 115 mm dia and 100 mm height ISI marked complete all as specified and directed by Engr in charge. |
| 30 | Supply and fix in replacement PVC Spacers 2/4 way for LT OH Line 1100 Volts grade with necessary screws nuts bolts etc complete all as specified and directed to prevent the lines touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old/out lived spacers and directed. |
| 31 | Supply and fixing in replacementCable route indicator made out cast iron and embossed HTCable on the plate of size 80 mm dia 5 mm thick with angle iron legs of 1.5 metre and grouting legs in PCC 1:3:6 foundation of suitable size complete all as directed and directed by Engr in Charge. |
| 32 | M&L for taking out old burnt cables & thimbles from loop and fixing toLT Panel completely after making good condition with suitable lugsupto cable 16 to 120 sqmm fixing to MCCB\"s including necessary excavationwork & minor spare parts i.e thimbles, nut, bolts ,para tape etc complete all as specified and directed. |
| 33 | M&L for denting, welding/fixing of hinge to panel door of various capacity including painting of doors after welding,with Smoke grey paint& cleaning of exposed surface with brush, empry paper complete all as specified and directed by Engineer-in-Charge |
| 34 | S&F 1100 volts grade heavy duty cable, 4 sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core cable flatincluding taking down old unserviceable cable for the following sizes :- |
| 35 | S&F 1100 volts grade heavy duty cable, 6 sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core cable flatincluding taking down old unserviceable cable for the following sizes :- |
| 36 | Supply and fixingDanger notice Plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps, bolts and nuts of approved size, for LT ,20x15 CM size and directed by Engr in Charge. |
| 37 | S&F in replacement FRP Junction box, light weight low corrosive suitable for pole mounting including MCB SP 6/10 amps , Box size not less than 250x200x100 mm including necessary connection for loop in and loop out cable connector and suitable size for cable glands complete all as specified and directed by Engr in Charge. |
| 38 | S & F in replacement PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core ISI marked.complete from light fitting to pole junction box complete all as specified. |
| 39 | S&F in replacement Voltmeter three phase class 0.5 with digital displayincluding taking down old UNSV Voltmeter complete all as specified and directed by Engr in Charge. |
| 40 | S&F in replacementammeter three phase class 0.5 with digital displayincluding taking down old UNSV ammeter complete all as specified and directed by Engr in Charge. |
| 41 | S&F in replacement LED type indicator lamp (RYB) including taking down old UNSV indicator lamp set of three complete all as specified and directed by Engr in Charge. |
| 42 | S&F in rep, MCCB 4 Pole , 63 Amps , 16 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 43 | S&F in replacement , MCCB 4 Pole , 100 Amps , 16 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 44 | S&F in replacement, MCCB 4 Pole , 125 Amps , 16 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 45 | S&F in replacement , MCCB 4 Pole , 160 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 46 | S&F in replacement , MCCB 4 Pole , 200 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 47 | S&F in replacement , MCCB 4 Pole , 250 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 48 | S&F in replacement , MCCB 4 Pole , 350 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed by Engr in Charge. |
| 49 | S&F in replacementBusBar Chamber TPN Type with Aluminium Bus Bar of capacity 320 Amp with 4 Nos out going, IP 42 protection complete with fixing on wall /Panel with suitable size of nut , bolts etc including electrical Connection complete all as specified and directed. |
| 50 | Supply and fix Display Board (double sided) of Size 1.50m x1.0m x 0.30m made with Back lit flex board mounted on suitable iron frame & printing of Installation detail both side of the board with GI pipe legs heavy grade min 80 mm dia of length min 1.5 meterwith suitable PCC foundation as per site requirement,Printing detail/ installation detail provided by JE/AGE including fixation of2x20 Watt LED light inside the board and also arrangement connection wire from the nearest LT panel/pole complete all as specified and directed by Engr in charge. |
| 51 | S&F in replacement post top lantern LED type 25 watt 230 voltsAC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including suitable size of GI Pipe as per lamp size including connection and testing complete all as specified and directed by Engr in Charge.Make : Havells Cat No. RUBYNXTPT25WLED757PSYMTOPCor equivalent model of makes specified. |
| 52 | S&F in replacementgarden light of Bamboo type -IP 65 ofNew generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source with PCC Base of size 1 feet x 1 feetfor fixing of lights with proper nut & bolts including elect connection wire complete all as specified and directed by Engr in Charge. Make : HAVELLSCat No.TURINBLS10WLED857PSYMTOPCor equivalent model of makes specified. |
| 53 | S&F in replacementLED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including PVC copper wire 1.5 sqmm of suitable length for connection of street light from Overhead conductor /junction boxcomplete all as specified and directed.Make :Havells Cat No ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent model of makes specified. |
| 54 | S&F in replacementLED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including PVC copper wire 1.5 sqmm of suitable length for connection of street light from Overhead conductor /junction boxcomplete all as specified and directed.Make : Havells Cat No ENDURAPEARLNEOSL60WLED757PASYTOPCor equivalent model of makes specified. |
| 55 | S&F in replacementLED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including PVC copper wire 1.5 sqmm of suitable length for connection of street light from Overhead conductor /junction boxcomplete all as specified and directed.Make :Havells Cat No ENDURAPEARLMAGSL120WLED757PASYTOTGASTHOor equivalent model of makes specified. |
| 56 | S&F in replacementbracket for street light,made out of GI Pipe medium grade of suitable size (40 mm dia and 1.2 mtr long) bent to shape ,fixed with and including necessary heavy duty clamps of suitable size including painting the clamps with two coats of synthetic enamel paint over a coat of primer all as specified and as directed. |
| 57 | Supply and errection of steel tubular swaged poles complete with cast iron base plate , finial tapper plug , bolts,nuts & screws as specified type 410 SP - 31, 9.00 Mtr longincluding one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching and painting with bituminous paint internally including writing the pole number in white letters on black background complete and externally for portion embedded in PCC, complete all as specified and directed. Note :- Excavation & earthwork and PCC in foundationof poles,coping etcshall be measured and paid under respective items |
| 58 | M&L for PCC 1:4:8 Type D2 using 40mm graded aggregate for base foundation complete all as specified and directed by Engr in Charge. |
| 59 | M&L for PCC (1:3:6) type C-1 with 20 mm gradded stone aggregate for coping ofpoles Pedestalincluding necessary form workcomplete all as specified and directed by Engr in Charge. |
| 60 | Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 600 amps rating installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement withincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning and including following items. (Notes : The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL |
| 61 | in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board )Golconda Enclave:-Incoming:-(a)MCCB250 Amp 4 pole 35/36 KA with overload & thermal release setting - 01 NoOutgoing:- (a)MCCB 100 Amp 4 pole 35/36 KA with overload & adjustable thermal release setting - 03 No(b)MCB TPN 63 Amp 36 KA -01 Nos(c)MCB SP 20 Amp \"C\" curve 10 KA -01 Nos(d)Astronomical time switch 1P Module, 24 hours program, Programmable every 15 min., backup of 100 hours, current capacity 16A, with 1 changeover (1 CO) complete with all accessories - 01 Nos(e)Bus bar electrolytic grade Aluminiumand supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60cm long mounted on insulators for outgoing supply -01 Set.(RYB) (f) LED type indicator lamp - 01 Set (03 Nos)(g)Digital panel mounted multifunctional meter Amp/volt & Frequency with LED Display-01 No |
| 62 | Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 600 amps rating installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement withincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning and including following items. (Notes : The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling |
| 63 | in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ) (Bde HQ P-01) :-Incoming:-(a)MCCB400 Amp 4 pole 35/36 KA with overload & thermal release setting - 01 NoOutgoing:- (a)MCCB 200 Amp 4 pole 35/36 KA with overload & adjustable thermal release setting - 02 No(b) MCCB 100 Amp 4 pole 35/36 KA with overload & adjustable thermal release setting - 02 No(c)MCB TPN 63 Amp 10 KA -01 Nos(d)MCB SP 20 Amp \"C\" curve 10 KA -01 Nos(e)Astronomical time switch 1P Module, 24 hours program, Programmable every 15 min., backup of 100 hours, current capacity 16A, with 1 changeover (1 CO) complete with all accessories - 01 Nos(f)Bus bar electrolytic grade Aluminiumand supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60cm long mounted on insulators for outgoing supply -01 Set.(RYB) (g) LED type indicator lamp - 01 Set (03 Nos)(h)Digital panel mounted multifunctional meter Amp/volt & Frequency with LED Display-01 No |
| 64 | Material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers andconnections by usingGalvanised Iron strip of 32 x 6mmas earthing lead(upto the body ofthe equipment) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 2020(Part-I)complete all as specified and directed. |
| 65 | Material & Labour for General servicing of 1.5 TR capacity window type AC after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any, prepartion of surface and removing dents & spray painting to Window type AC of 1.5 TR with two coats of synthetic enamel paint over one coat of red oxide primer and writting SM/MES No.including re-fixing the AC in same/ other location and connecting, commissioning complete all as directed. |
| 66 | All as per item No 63 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 67 | All as per item No 63 here in above but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 68 | All as per item No 63 here in above above but Water Cooler of capacity 40/40, 40/80, 60/120 &150/150 Ltr |
| 69 | All as per item No 63 here in above but Refrigerator of capacity 165 to 310 Ltrs. |
| 70 | All as per item No 63 here in above above but Desert cooler of capacity upto 4000 Cum/hr |
| 71 | Material & Labour for General servicing of 1.5 TR capacity window type AC after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any including re fixing the AC in same/ other location and connecting, commissioning complete all as directed. |
| 72 | All as per item No 69 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 73 | All as per item No 69 here in above but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. Notes for items No 63 to 71Major spares are measured and paid separately under relevant item in BOQ. |
| 74 | Supply& Fix in repair Running capacitor 45/50 MFD suitable for Window/Split type AC/water cooler all as specified. |
| 75 | All as per item No 72 here in above but 36 MFD. |
| 76 | All as per item No 72 here inabove but 10 MFD. |
| 77 | All as per item No 72 here in above but 4 MFD, 240 Volt for desert cooler. |
| 78 | Supply & Fix in repair Capacitor 6 MFD, 240 Volt suitable for fan motor of Window / Split type AC all as specified and as directed. |
| 79 | S&F in replacement of Hermetically sealed compressor unit suitable for Window / split type ACs of1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified & directed.(Existing Make:- Voltas/ Carrier/ Blue star/ Kirloskar/ Tuchmesh/ Usha/ Godrej/ Whirlpool/ LG/ Kenstar)(i) Connection to suction/discharge pipe with necessary repair and brazing. (ii) Replacing the capillary tubes of existing size and copper liquid filter. (iii) Flushing of entire system before gas charging.(iv) Gas charging and testing after complete repairs including installation of the machine at site and testing on full load for its smooth functioning complete. |
| 80 | All as peritem No 77here in above but 2.0 TR |
| 81 | All as peritem No 77here in above but suitable for Refrigerator of capacity 165 to185 Ltr. |
| 82 | All as peritem No 77here in above but suitable for Refrigerator of capacity 258 to 310 Ltr. |
| 83 | All as peritem No 77 here in above but suitable for water cooler of capacity 40/40, 40/80 Litres |
| 84 | All as peritem No 77here in above but suitable for Water Cooler of capacity 60/120 |
| 85 | All as peritem No 77here in above but suitable for Water Cooler of capacity 150/150 |
| 86 | S&F in repairs Copper Condensing coil and aluminium fins suitable for 1.5 TR capacity Window type Air conditioner including necessary brazing, gas charging, leak testing, Vacuuming etc including taking down old unserviceable condensing coil complete all as specified. |
| 87 | All as per item No 84 here in above but Indoor unit of Split type type Air Conditioner 1.5/2.0 Ton. |
| 88 | All as per item No 84 here in above but Outdoor unit of Split type type Air Conditioner 1.5/2.0 Ton. |
| 89 | All as peritem No 84 here inabove but condensor coil suitable for Watercooler of capacity 40/40, 40/80 |
| 90 | All as per item No 84 here inabove but condensor coil suitable for Watercooler of capacity 60/120 |
| 91 | S&F in repairs copper condensing coil and metallic fins suitable for 165 to 185 Ltrs capacity Refrigerator including necessary brazing, gas charging, leak testing, Vacuumising etc including taking down old unserviceable condensing coil complete all as specified. |
| 92 | All as per item No 89 here in above but condensor coil suitable for refrigerator of capacity 258 to 310 Ltrs. |
| 93 | S&F in repairs Copper tube 1/2\" including nitrile rubber insulation for suction refrigerant line suitable for split type AC 1.5 TR complete all as specified and directed. |
| 94 | All as per item No 91 here in above but 5/8\" suitable for split AC 2.0 TR. |
| 95 | S&F in repairs Copper tube 1/4\" including nitrile rubber insulation for discharge refrigerant line suitable for split type AC 1.5 TR complete all as specified and directed. |
| 96 | All as per item No 93 here in above but 3/8\" suitable for split AC 2.0 TR. |
| 97 | M&L in repairs, cutting, removing of burnt winding of fan motor/condenser fan motor of window type AC of any make and rewinding with super enameled copper winding wire of existing size and weight including replacement of bushingfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed. |
| 98 | All as per item No 95 here in above but Spilt type AC 1.5/2.0 TR |
| 99 | S&F in repairs Prime ControlRemote Board andtemperature digital display sensor suitable for non inventer type Split AC/Window AC of existing capacity, make or model all as per site requirement complete all as directed.Note:(i) The contractor shall ensure 10% of all PCB models in stock to rectify the complaints on emergency basis. |
| 100 | S&F in repairs, Remotefor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed. |
| 101 | All as per item No 98 here in above but Spilt type AC 1.5/2.0 TR |
| 102 | Material & Labour for Leak testing of Window type Air Conditioner of capacity 1.5 TR includingfilling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas (R-22) of required quantity, testing for proper functioning all as specified and directed.NOTE : Charging of Refrigerant gas are measured and paid separately. |
| 103 | All as per item No 100 here in above but Split type Air Conditioner 1.5/2.0 Ton. |
| 104 | Supply and charging Refrigerant Gas-R-22 and testing complete all as specified and as directed. |
| 105 | All as per item No 102 here in above but Refrigerant Gas R- 32. |
| 106 | All as per item No 102 here in above but Refrigerant Gas R- 132A |
| 107 | S&F in repair Fan motor 1/5 HP, 240v long shaftsuitable for Window type AC of any capacity, make or model all as specified and as directed. |
| 108 | S&F in repair Fan motor 1/5 HP 240v suitable for outdoor unit of split type AC of any capacity, make or model all as specified and as directed. |
| 109 | S&F in repair Fan motor 1/35 HP 240v with leaf suitable for water cooler all as specified and as directed. |
| 110 | S&F in repair Fan motor 1/35 HP 240v with leaf suitable for Desert cooler all as specified and as directed. |
| 111 | S&F in repair Fan blade suitable for Window type AC of any capacity, make or model all as specified and as directed. |
| 112 | S&F in repair Fan blade suitable for Outdoor unit of Split type AC of any capacity complete all as specified and as directed. |
| 113 | S&F in repair Fan blade made of aluminium/plastic of superior quality for desert cooler of any type and capacity all as specified and as directed. |
| 114 | S&F in repair Fan blade for motor suitable for water cooler of 80 to 150 litre capacity as per existing make & model all as specified and as directed. |
| 115 | M&L for repairs of blower of existing make and model of splittype AC of any capacitycomplete all as specified and as directed. |
| 116 | M&L for repairs of swing assembly of existing make and model of splittype AC of capacity 1.5/2.0 TR complete all as specified and as directed. |
| 117 | M&L for repairs of swing motor of existing make and model of splittype AC of capacity 1.5/2.0 TR complete all as specified and as directed. |
| 118 | S&F in repairs, Relay as per existing make and model of splittype AC of capacity1.5/2.0 TR, single phase, 240 Volts, AC supply including connecting and testing of relay all as specified and as directed. |
| 119 | All as peritem No 116here in above but suitable for Water cooler 40/40 & 40/80 ltr capacity. |
| 120 | All as peritem No 116here in above but suitable for Water cooler 60/120 & 150/150 ltr capacity. |
| 121 | All as peritem No 116here in above but suitable for refrigerator upto 310 ltr capacity. |
| 122 | S&F in repairs, over load protector for existing make and model of splittype AC of capacity 1.5/2.0 TR,all as specified and as directed. |
| 123 | All as peritem No 120here in above but suitable for Water cooler 40/40 & 40/80 ltr capacity. |
| 124 | All as peritem No 120here in above but suitable for Water cooler 60/120 & 150/150 ltr capacity. |
| 125 | All as peritem No 120here in above but suitable for refrigerator upto 310 ltr capacity. |
| 126 | S&F in repairs, thermostat suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed. |
| 127 | All as peritem No 62here in above but suitable for Water cooler 60/120 & 150/150 ltr capacity. |
| 128 | S&F in repairs,thermostat switch (auto de-frost) suitable for refrigerator of 165 to 310 ltr capacity as per existing make & model all as specified and as directed. |
| 129 | M&L in repairs, rewinding of fan motor suitable for water cooler of 60/120 & 150/150 litre capacity of any make with super enameled copper wire of existing size and weight as required including replacement of bushing and capacitor of 4.0 mfd complete all as specified and as directed. |
| 130 | Dusting using blower and cleaning the housing from inside/out side, cooling system, cooling coil, condenser,capillary tube complete washingwith CTC liquid and leak detection, testingfor water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed. |
| 131 | Taking down Air cooler/ desert cooler of any size and make from bracket/ stand, spanning all three side shutters and taking out old wooden chips pad, cleaning outer and inner surface by rubbing with sand paper or wire brush, including water tank complete and replacement of cooling pad of set of three of any size, superior quality with chicken wire mesh, oiling/greasing to motor and pump, including re-fixing properly at the same place as required at site. |
| 132 | M&L in repairs/replacement of water circulating submersible pump with motor 1/20 HP, 230 volts AC, ISI marked including electric connection for desert cooler of any type and capacity all as specified and as directed. |
| 133 | M&L in repairs, PVC water distributor with PVC elbow and pipe for desert cooler of any type and capacity all as specified and as directed. Note:-This item includes the cost of elbow - 03 Nos, pipe-03 Nos of required length and dia and distributor -01 No |
| 134 | M&L in repairs, PVC insulated, sheathed, flexible, round, 3 core cable with copper conductor of size 1.0 sqmm, upto 2m length with 3 pin top all as specified and as directed. |
| 135 | S&F in repairs, plug top, 3 pin, 6 amp, 230V AC, ISI marked all as specified and as directed. |
| 136 | S&F in repairs, Socket outlet 3 pin, 6A, flush type, 230 V complete all as specified and as directed. |
| 137 | S&F in repairs, 3 speed regulator switch for desert cooler completeall as specified and as directed. |
| 138 | M&L for repair to body (viz. sides, base, bottom of tank) of water cooler of any make/size by replacing rusted worn out portion with suitable plain mild steel sheet of existing gauge to match original, mild steel angle iron suitable to match the existing body including transportation from MES store yard to repair shop and back complete all as specified and as directed. |
| 139 | S&F in repairs, heater for frost freerefrigerator of any type and capacity, as per existing make & model all as specified and as directed. |
| 140 | S&F in repairs, freezer chest with cooling coil suitable for refrigerator 165 to 310 litre capacity as per existing make & model and fixing, connecting and testing completeall as specified and as directed. |
| 141 | S&F in repairs, electric lamp pin/ threaded type, 240 volts, AC supplysuitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed. |
| 142 | S&F in repairs, magnetic door gasket, superior quality, suitable for refrigerator/ Water Cooler of any capacity as per existing make & model all as specified and as directed. |
| 143 | S&F in repairs, leg, suitable for refrigerator/Water Cooler of any capacity as per existing make & model all as specified and as directed. |
| 144 | S&F in repairs, capillary tube and drier filter, suitable for refrigerator of 165 to 310 ltr capacitywith brazing, nitrogen flushing, leak testing and gas charging all as specified and as directed.Note:- Charging of gas as specified by manufacturer will be measured and paid separately under respective item. |
| 145 | All as per serial item No 142 but for water cooler 60/120 & 150/150 Ltr cooling capacity. |
| 146 | S&F in repairs, PVC flexible drain pipe length 2 meter, with proper fixing clip as per existing type & size suitable for water cooler any capacity all as specified and as directed. |
| 147 | S&F in repairs,PTMT float valve assembly of 15 mm bore with plastic ball with suitable connections galvanized iron nipple 3” long and suitable GI sheet for fixing float valve suitable for water cooler of any make all as specified and as directed. |
| 148 | S&F in repairs, 15mm bore stop cock, cast copper alloy, ISI marked, all as specified and as directed. |
| 149 | S&F in repairs, GI pipe connector (male and female) 15mm bore pipe all as specified and as directed. |
| 150 | S&F in repairs, 15 mm dia, concussive push taps of stainless steel alloy, screwed for iron pipe for water cooler all as specified and as directed. |
| 151 | S&F in repairs/replacement ofPVC air filter, 20 micronfor existing make and model ofAC any capacity 1.5/2.0/3.0TR all as specified and as directed. |
| 152 | S&F in repairs/replacement of internal wiring kit of PVC insulated copper conductor wirefor existing make and model ofAC any capacity 1.5 /2.0 TR all as specified and as directed. |
| 153 | S&F in repairs/replacement of shut off valve brass with flair nut complete for existing make and model of ACany capacity 1.5/2.0 TR all as specified and as directed. |
| 154 | Supply and replace factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including necessary PCC work, making surface matching with existing etc, all as specified. |
| 155 | S&F in repairs, nylon pipe, cotton breaded, size 15mm dia, suitable for drain of split type AC, capacity 1.5/2.0 TR all as specified and as directed. |
| 156 | Material & Labour for spray painting single coat anti corrosive enamel paint to cover of window AC of any capacity complete all as specified and directed. |
| 157 | Material & Labour for spray painting single coat anti corrosive enamel paint to outer unit of split AC 1.5/2.0 TR capacity complete all as specified and directed. |
| 158 | S&F in repairs 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5 Sqmm complete all as specified and as directed |
| 159 | S&F in repairs, sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB, single pole, 20 amp, 240 volts complete all as specified and as directed. |
| 160 | Supply & Fix in replacement of MCB SP 6 to32 Amps \"C\" series 240 Volt, complete all as specified and directed. |
| 161 | S&F in repairs, switch socket combination multipurpose flush type 5 in 1 type, 6/16 Amps, 230V, AC. Make - Plaza / Havells / Leader /Vinay. |
| 162 | Material & Labour for sub main wiring on wall /ceilingwith 2 runs of 4 Sqmm single core PVC insulated un sheathed multi stranded copper cunductor FRLS cable 1100 Volt grade drawn through andincluding PVC conduit pipe of medium grade not less than 20mm dia including PVC conduit specials and 1 run of 4 Sqmm cable single core 1100 Volt grade multi stranded copper conductor FRLS cable as earth continuity conductor and connecting with suitable size thimble including taking down of old one complete all as specifed and as directedNote: Two runs of sub main wire, One run of earth wire and PVC conduit with accessories shall be measured as One unit. |
| 163 | Opening of voltage stabilizer of AC, single phase, 230V of 1/2/3/4/5 KVA capacity & make and detection of fault and repair to voltage stabilizer by rewinding the main stabilizing unit and replacement of defective parts like volt meter, auto cut relay, time delay relay PCB cards, LED, Switch Socket etc as per existing make and model as required at site. Notes : Parts rate include in this job. |
| 164 | S&F in repairs, transformer suitable for 1/2/3/4/5 KVA voltage stabilizer as per existing make & type complete all as specified and as directed. |
| 165 | S&F in replacement of, voltage stabilizer, 5 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5%complete all as specified & as directed. |
| 166 | S&F in replacement of, voltage stabilizer, 4 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5%complete all as specified & as directed. |
| 167 | Disconnecting water and electrical connection, dismantling the accessories carefully of RO system ofcapacity 12 Ltrs,cleaning the exposed surface and refixing the same to its original position, connecting up of water/electric connections after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per existing(ii) S&F in repairs of parts will be measured and paid separately. |
| 168 | S&F in repairs, pre filter for 12 Ltr capacity RO system complete all as specified and as directed. |
| 169 | S&F in repairs, carbon block filter for 12 Ltrs capacity complete all as specified and directed. |
| 170 | S&F in repairs, UV for 12 Ltr capacity RO system complete all as specified and as directed. |
| 171 | S&F in repairs, membrancefor 12 Ltr capacity RO system complete all as specified and as directed. |
| 172 | S&F in repairs, pressure pumpfor 12 Ltr capacity RO system complete all as specified and as directed. |
| 173 | Material and labour for attending day to day complaints pertains to various capacity of cooling appliances as and when required by Refrigerator Mechanic and helper with necessary tools and plants for checking the equipment at existing location, find out the faults to the equipments, complete and rectificationof minor problems (compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections to make the AC functional in all respect all as directed by the Engineer -In Charge.Notes: 1.Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis.2..A penalty of Rs. 250/- per day will be levied in case breakdown of equipment more than 24 hours from the time of complaint registration due to non attending. 3.The Item shall be measured and paid only when no replacement of spares included in the repair work. If any spare replacement included in the work, the work shall be measured and paid under relavent item only. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail