| 1 | Replacement of following defective electric items and control wiring, power wiring ofexisting High mast light control panel again connection with power wiring 6 Sq mm FRLS single core Copper conductor and control wiring 1.5 Sq mm FRLS single core Copper conductor, proper numbering of ferrule shuold be maintained complete with connections, testing and commissioning etc. as required.i) 01 No- Multifunction timer with digital display 20-240V AC/DC 15 functions make ABB/L&T/Schneider/ Simence Cat No. 7PV0723-1AV20ii) 01 No- Power Contractor Rated current 45A3pole 415V AC 50 Hz, contractor coil 230 V AC Auxiliary contacts 2 NO + 2 NC makeABB/L&T/Schneider/ Simence Cat No. 3TF4602-0Aiii) 02 Nos - Power Contractor Rated current 12A3pole 415V AC 50 Hz, contractor coil 230 V AC Auxiliary contacts 2 NO + 2 NC makeABB/L&T/Schneider/ Simence Cat No. 3TF3101-0Aiv) 01 No- 40 A rating, 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of four poles Make L &T/ ABB/Simence/Schneider |
| 2 | Providing and fixingof Industrial plug and socket 5(3P+N+E) poles IP 67 protection 415 Voltcurrent rating 32 Amp complete with connections, testing and commissioning etc. as required. |
| 3 | SITC of 1.5 HP, 3-Phase induction motor, 415 volt, speed- 1440-1725 rpm totally enclosed fan cooled type, Usally designed for upto 300 kg carriage laod including Gear Box, stainless steel rope with proper end termination, and Mechanical or electric break, overlaod protection, emergency stop, fitting connections, interconnections etc as per specification complete as required. |
| 4 | Supplying and Laying of one number PVC insulated and PVC Round Sheathed. Multicore Annealed Bare Copper Conductor industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694: 2010 of following size in the existing METAL pipe and connection as required (a) 4 x 4.00 sq. mm |
| 5 | Supply, installation, testing and commissioning of 01 luminaries having wattage of 200 W each (Variation of more than +/- 5% would not be allowed) having minimum system efficiency of 110 lumen/watt outdoor type LED Flood Light Luminaire of IP 66, Accuracy Class-I, is 10122 and above having suitable pressure die cast housing/heat sink, driver, optics for operation in 230 Volts A.C, PF not less than 0.90, CRI≥70, internal $ external surge protection, colour temperature 6500 K, suitable with beam angle to meet desired aluminium level as per required technical specification & suitable for mounting on the exiting pole bracket including drilling of holes,i/c providing and fixingsuitable size of GI flexible pipe with accessories form top slot of pole to fittingconnections, interconnections etc as per specification complete as required |
| 6 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 7 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |