| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundationin hard/dense soil complete all as specified and as directed |
| 2 | M&L for plain cement concrete in foundations, filling and mass concrete using 1:4:8, nominal mixtype D-2 (using 40mm graded crushedstone aggregates) complete all as specified and directed. |
| 3 | Returning,filling in including spreading ,leveling ,waterring and well ramming in layers not exc 25cm thick with excavated soil complete all as specified and as directed |
| 4 | Removingexcavation material/soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed |
| 5 | S&F TMT bar Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with and including mild steel wire (annealed) not lessthan 0.9mm dia or securing with clips complete all as specified anddirected. |
| 6 | S&F TMT bar Mild steel bars 6 to 8 mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with and including mild steel wire (annealed) not lessthan 0.9mm dia or securing with clips complete all as specified anddirected. |
| 7 | All as Srl item No.06 above, but 5mm dia and over upto and including10mm dia in stirrups, spacers and binders complete all as specified anddirected. |
| 8 | M&L for RCC M-20(design mix) (using 20mm graded crushed stone aggregates) as in foundation, footing, foundation beam, plinth beam, base for columns, etc. complete all as specifiedand as directed Note:Reinforcement shall bemeasured and paid separately. |
| 9 | M&L for RCC M-20(design mix) (using 20mm graded crushed stone aggregates) as in columns, etc. complete all as specifiedand as directed Note:Reinforcement shall bemeasured and paid separately. |
| 10 | M&L forRCC M-20(design mix) (using 20mm graded crushed stone aggregates) as in roof beam supported on wall, column, lintel complete all as specifiedand as directed Note:Reinforcement shall bemeasured and paid separately. |
| 11 | M&L forRCC M-20(design mix) (using 20mm graded crushed stone aggregates) as in slabs supported on walls, beamscomplete all as specified anddirected. |
| 12 | M&L forform work to sides of concrete foundation, footings, bases of columns ,sides and sofit of foundation and plinth beam and similar works vertical or to batter in rough finished surface of concrete of flat surface complete all as specified and as directed |
| 13 | M&L for form work to sides of pillars, posts,columns,struts, piers and stanchions in rough finished surface of concrete of flat surface in square or rectangular shape complete all as specified and as directed |
| 14 | M&L for formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc in rough finished surface of concrete of flat surface complete all as specified and as directed |
| 15 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs,shleves landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified anddirected. |
| 16 | M&L for use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs, sides of RCC/PCC bands in walls, horizontal or sloping and similar works exc 10 cm but not exc. 20 cm wide for rough finished surfaces of concrete complete all as specified and directed. |
| 17 | M&L for pre-cast cement concrete block 1:3:6 type C1 (using 20mm nominal size crushed and graded stone aggregates) masonrywith solid blocks, setting in cement mortar 1:6 having minimum compressive strength of 50 Kg/Sqcmcomplete all as specified and as directed |
| 18 | M&Lfor 15 mm thick rendering in CM (1:4) on faces of brick or concrete surfaces finished even and smooth without using extra cement with using WPC 3% by weight of cement on wall complete all as specified and as directed Note:-WPC shall be measured and paid seperately |
| 19 | M&L for 10 mm thick rendering in CM (1:3) on faces of brick or concrete surfaces of ceiling, soffit and finished even and smooth without using extra cement complete all as specified and as directed |
| 20 | M&L 10 mm thick rendering in CM (1:3) on unfair faces of brick or concrete surfaces on RCC Rooftop and finished even and smooth without using extra cement with using WPC 3% by weight of cement over roof complete all as specified and as directed Note:-WPC shall be measured and paid separately |
| 21 | Supply only water proofing compound as per IS : 2645 complete all as specified and as directed |
| 22 | M&L for applying two or more coats of 100% Premium acrylic emulsion having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/sqm over new surfaces including 1.5mm thick wall care putty complete all as specified and directed. |
| 23 | M&L for preparation of newly plastered ceiling surfaces applying three coats of white wash on ceiling surfaces complete all as specified and directed. |
| 24 | M&L for providing and laying plain cement concrete, 75mm thick 1:3:6, type C1 (using 20mm nominal size crushed and graded stone aggregates) for plinth protection inlcuding filling of expansion joint with bituminous mixture finished fair and even complete all as specified and as directed |
| 25 | M&L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 Kg/Sqm including cleaning surface complete all as specified and directed. |
| 26 | M&L for applying one coat of bituminious/polymerized primer confirming to IS-3384 @0.30 litre/Sqm and laying Actetic Poly Propylene (APP) modified membrane pre fabricated, reinforced with non woven polyester, of 3.0 Kg/Sqm (minimum), 3mm thick with minimum 75 mm side overlaps and minimum100mm and applying one coat of bituminious aluminium paint over APP membrane complete all as specified and as directed |
| 27 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 28 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headedounter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hingesshall be measured and paid separately |
| 29 | S&F 100 mm butt hinges, medium weightcold rolled, mild steel and fixed complete all as specified and as directed |
| 30 | S&F 150mm long cast type anodised aluminium handle complete all as specified and as directed |
| 31 | S&F250mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and as directed |
| 32 | S&F200mm long aluminium anodised tower bolts of extruded section and fixed complete all as specified and directed. |
| 33 | Supplying and laying 32mm nominal size CPVC pipes SDR 11 including plain & brass threaded special fittings of same size or of reducer or enlarged size on walls/ceiling or laying in floors and necessary cutting /chases in wall/floor of any description and making good the disturbed portion complete all as specified and as directed |
| 34 | Supplying and laying 20 mm nominal size CPVC pipes SDR 11 including plain & brass threaded special fittings of same size or of reducer or enlarged size on walls/ceiling or laying in floors and necessary cutting /chases in wall/floor of any description and making good the disturbed portion complete all as specified and as directed |
| 35 | S&F powder coated aluminium sliding window shutters with frames (minimum thickness of powder coating 50 micron) three track ( consisting of 02 Nos glazed shutters and 01 No gauge shutter) without sash bars including necessary joining cleats, glazing clips, EPDM rubber packing, powder aluminium snap beading, screws, wheels, locking arrangements, suitable handles for sliding purpose, 4mm thick frosted glass and mesh of dia 0.36mm and 1.40mm width of aperture, silicon chemical filling at gaps between section frame and wall surfaces complete all as specified and as directed .. |
| 36 | S&Fpowder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators, partitions with one or more rebates including jointing cleats for fixing each other etc and bathroom lovered sections complete all as specified and as directed . |
| 37 | S&F Anodised aluminium ventilator shutters/ Al louvered strip powder coated (minimum thickness of powder coating 50 micron), side/top hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazinglips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.)suiitable handle (1 No.)complete in all respect as specified and directed |
| 38 | M&Lfor12mm thick panel board (High Pressure Laminated (HPL) ) as in partition wall anddoor shutter on site as per site requirement. The Panel shall be fixed in wall through standard SS profile(Wall bracket). The top of Panel shall be fixed through standard SS profile( H-type top rail with cover), The \"T\" junction of panel shall be fixed through standard SS profile. The bottom of panel shall be fixed through standard SS profile adjustable foot of maximum 75mm height. The Panel door shall have standard SS,hinge(spring loaded butt hinge), Door Knob pair, privacy thumbturn, locking arrangement, floor anchor, occupancy indicatoretc. The each shutter shall have one SS Coat Hook cum door stopper complete all as specified and directed. Make:-HPL/Greenlam Laminates, Alstone India, Merino Laminates |
| 39 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including mild steel clamps of suitable size complete all as specifed and directed. |
| 40 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 41 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including mild steel clamps of suitable size complete all as specifed and directed. |
| 42 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 43 | S&F PVC (SWR) vent cowl 110mm bore complete all as specifed and directed. |
| 44 | S&F 110 mm bore PVC (SWR) bends with access door any radius complete all as specifed and directed. |
| 45 | S&F PVC (SWR) Bend radius with access door any radius 75mm bore complete all as specifed and directed. |
| 46 | S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm bore complete all as specified and as directed |
| 47 | S&F PVC (SWR) junction single, (single T) equal or unequal with access door 75 mm bore complete all as specified and as directed |
| 48 | S&F PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 49 | M&L for 50mm borehigh density polyethylene pipes (HDPE) and fittings of pressure rating 6 Kg/sqcm fixed complete to walls, ceilings and or infloors as drain out pipe etcincluding necessary cutting and chasing to wall or floor of any description complete all as specified and as directed |
| 50 | M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and as directed |
| 51 | M&L for providing and laying plain cement concrete, 75mm thick 1:4:8, type D1 (using 20mm nominal size crushed and graded stone aggregates) for sub-base of floors or similar workfinished fair and even complete all as specified and as directed . |
| 52 | M&L for providing and laying cement concrete, 25mm thick 1:2:4 type B0 (using 12.5mm nominal size crushed and graded stone aggregates) for levelling to receive screed for laying floor finish, finished fair and even complete all as specified and as directed . |
| 53 | M&L for non skid coloured ceramic floor tiles of size of tile not exc.0.36 sqm each, 6mm to 7mm thick (square/rectangular) as in floor laid over and including 15mm thick screed bed in CM (1:4),set, jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tilecomplete all as specified and as directed |
| 54 | M&L for coloured glazed ceramic tiles jointless/edge cutted of size exc 0.09 Sqm but not exc 0.18 sqm,6mm to 7mm thick as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick backing/rendering in CM(1:4)complete all as specified and as directed . |
| 55 | S&F in repairs vitreous China wash hand basin, white in colour,flat back of size 550mmX400mmX200mm including pedastal, and 32mm bore dia CP finish copper alloy waste fitting/coupling, 32mm bore dia PVC waste pipe including cutting for and pinning in ends of brackets or erecting stand brackets complete all as specifiedand directed |
| 56 | S&F in repairsfancy swan neck pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specifiedand directed . |
| 57 | M&L for providing and laying plain cement concrete,1:2:4, type B1 (using 20mm nominal size crushed and graded stone aggregates) as in coping, damp proof Course, holdfast or similar type of work inlcuding necessary formwork complete all as specified and as directed . |
| 58 | Demolition of cement concrete of any description and in any position not otherwise specially described for complete all as specified and directed |
| 59 | M&L for sand filling and paver block/floors or in foundations inlcuding watering and consolidation complete all as specified and as directed . |
| 60 | M&Lfor 60mm thick rubber mould, machinepressed precast concrete interlocking paver block, rubber mould of any shape and size confirming to IS-15658-2006, M-35 grade of concrete with grey cement and pigment complete all as specified and as directed . |
| 61 | S&F vitreous china squatting pan “ORISSA” pattern size 580mm X 440mm, white with P or S trap front or back inlet with integral foot rest &including necessary PCC bedding and connection to trap & to flushing pipe anti syphonage pipe etc complete all as specified & as directed. |
| 62 | S&F white vitreous China wash down water closet pan (pedastal) pattern, and trap(excluding flushing cistern) including plastic water closet seat, white closed pattern with flat bottom and cover and mild steel hinging device complete all as specified and as directed |
| 63 | S&F counter type vitreous China wash hand basin, oval shape of size 560mmX410mmX145mm including one number chromium plated waste fitting/coupling 32mm dia brass with long screwed shanks and fly nuts & including 32mm dia PVC waste pipe with connector fixing on Granite slab complete all as specified and directed |
| 64 | S&F in repair 5 mm thick looking mirror of selected quality glass mounted, edges to be moulded properly and fixed towall with chromium plated brass screws and cup washers complete all as specified & directed. |
| 65 | S&F PVC connection 15mm dia and 450 mm long with 2 Nos PTMT nuts with washerscomplete all as specified and directed. |
| 66 | S&F PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm bore complete all as specified and as directed |
| 67 | S&F CP toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated brass screws complete all as specified and directed |
| 68 | S&F CP soap dish fixed to wall with screw complete all as specified and directed. |
| 69 | S&F 20 mm dia Aluminium anodised tubular towel rail, D type, 60 cm long between flanges fixed with brass screws complete all as specified and directed. |
| 70 | S&FHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete complete all as specified and directed. |
| 71 | S&F angular two way bib tap with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 72 | S&F 15 mm bore chromium plated fancy type angle valve with elegant knob screwed down high pressure, with crutch or butter fly handle screwed for iron pipe or for unionscomplete all as specified and directed. |
| 73 | S&F 15 mm bore chromium plated fancy type short body bib taps with crutch or buttrfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 74 | S&F 1000 litrescapacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), triple layer wall construction, ISI marked, hoisted and fixed in position including 20/25mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball two nos tank nipples of PTMT material 25mm bore as required complete all as specified and as directed . |
| 75 | M&L for salt glazed stone ware (SGSW) drain pipe, 150mm dia (internal), grade ‘A’ laid in trenches and jointed including testing complete all as specified and as directed. |
| 76 | M&L for plain cement concrete type C2, 1:3:6 (using 40mm graded crushed stone aggregates) as in bed to drain pipes of 150 mm bore including packing under, and hunching against the sides of pipes after they are laid and testedcompleteall as specified & directed. |
| 77 | M&L for pre-cast cement concrete block 1:3:6, type C1 (using 20mm nominal size crushed and graded stone aggregates) masonrywith solid blocks, setting in cement mortar 1:4 having minimum compressive strength of 50 Kg/Sqcmcomplete all as specified and directed. |
| 78 | M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in surface channel bed/ drains/ in manholesall as specified laid to slope and finished surface even and smooth complete all as specified & directed. |
| 79 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms moulds, mitered/stopped ends etc. complete all as specified & directed. |
| 80 | M&L for precast RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in cover slab, set in cement mortar (1:6) complete all as specified and as directed.Note:-Reinforcement shall be measured and paid separately |
| 81 | M&L for point wiring for the following with stranded FRLSH copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including new non-metallic rigid PVCconcealedconduit, not less than 20 mm dia, medium duty ISI marked, including conduit fittings such as tees, bends etc terminating in and including modularmetak flush box , modular white cover plate any size with support frame any size module complete all as specified and as directed. cover of approved make, for one fan or light or exhaust fan orbell/buzzer pointcontrolled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed:- |
| 82 | One light point controlled by one, one way switch 5 Amp |
| 83 | One socket point on the same board with other switches |
| 84 | One light point controlled socket point on indpendent board |
| 85 | All as per Srl item No1.00above but one 3 pin socket outlet 15 Amps independent with cable 4 Sqmm size |
| 86 | S&Fswitch Modular type single pole 6 Amps One Way Switch AC 230V, 50HZ supply complete all as specified and as directed. Make :800100 of Indoaisian ELVIRA/ACWSXXW101 of Havells CRABTREE(Signia) or any other equivalent make as specified in list of makes of Particular Specifications |
| 87 | S&Fswitch Modular type single pole 16 Amps One Way Switch with indicator AC 230V, 50HZ supply complete all as specified and as directed. Make :800105 of Indoaisian ELVIRA/ACWSXIW161 of Havells CRABTREE(Signia) or any other equivalent make as specified in list of makes of Particular Specifications |
| 88 | S&FModular type socket5AAC 230V, 50HZ complete all as specified and as directed.Make : 802800 of Indoaisian ELVIRA/ACWKPXW063 of Havells CRABTREE(Signia) or any other equivalent make as specified in list of makes of Particular Specifications |
| 89 | S&FModular type SOCKET combine 6A/16A multi purpose AC 230CV, 50Hz complete all as specified and directedMake : 800122 of Indoaisian ELVIRA/ACWKCXW163 of Havells CRABTREE(Signia) or any other equivalent make as specified in list of makes of Particular Specifications |
| 90 | S&F ceiling rose surface backelitethree terminal 240 volts complete all as specified and directed |
| 91 | S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffusersoft glare free light complete with drivers, holders, LED lamp suitable for roof ceilingncludingconnecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 92 | S&FLED lights fitting 1x 10W, 220V, wall mountedLED batten with Aluminum Housing & integrated electronic driver including connecting up with 0.5Sqmm three core flexible copper conductor cablefrom ceiling rose complete all as specified and as directed.Make:-Cat Part No: LUMILINE+BS10WLED865SPCSS of Havellsor any other equivalent make as specified in list of makes of Particular Specifications |
| 93 | S&Fsheet metal enclosure Double Door factory made distribution board 240 volts SPN 8 way, 200 Amps rated bus bar complete all as specified and as directed. |
| 94 | M&L forfor MCB SPN 6 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified and directed. |
| 95 | M&L forfor MCB SP 06 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specifiedand directed. |
| 96 | S&F exhaust fan, PVC body AC single phase. 230V of size 300m sweep with, blades, and frame and louvers including cutting the wall as round shape for exhasut the air complete all as specified and directed. |
| 97 | M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and includingflat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge.(Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) . |
| 98 | S&F ENDURA SUN DOWN energy saving and environmental friendly long life LED street light made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP66 protection and impact resistance of IK08 LED street lightof 35 Watt withsutable sizebracket made to shape of 40 mm dia GI pipe medium grade of 1.4 mtr length including MS clamps 25 x 4 mm - 02 Nos with nut bolts washers complete all as specified and directed.Make:-Havells Cat Part No - ENDURASUNDOWNSL35WLED765PASYBOPCor any other equivalent make as specified in list of makes of Particular Specifications |
| 99 | Supplying, laying, testing and connecting of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm, 2 core cable complete all as specified and as directed. |
| 100 | Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and n. exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8 type D-2 complete all as specified and directed |
| 101 | S&F galvanised iron pipes40 mm dia,. light grade,with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified & directed |
| 102 | S&FDouble wall corrugated HDPE PipeIS-16205, outer dia 40 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings with calmp on wall as required at sitecomplete all as specified and as directed |
| 103 | S&F 25mm diastop valves, cast copper alloy, screweddown, highessure,withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete all as specified and directed |
| 104 | Supplying, laying, testing and commisioning galvanized medium grade GI tubing including fitting 25mm dia complete all as specified and directed |
| 105 | M&L for construction of valve pit chamber of size 750mmx750mmx750mm including necessary earth work in any type of soil, PCC foundation (1:3:6 ) type C-2(using 40mm graded crushed stone aggregates) as in base concrete, brick work in CM 1:6, 15 mm thick plaster internally in CM(1:4) and 15 mm thickplasterexternally in CM (1:4), 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40x40x6 mm MS angles complete with 2 coat of synthetic enamel paint over one coat of red oxide Zinc chromate primer on all metal works and three coats of white wash on all plastered surface of valve chambers complete all as specified and directed |
| 106 | Cutting existing D I PIPE /CI PIPE line for alterations or additions done in position without taking down upto150 mm dia pipe (Each cut measured) complete allas specified and directed |