| 1 | Taking down/ Dismentaling of old rusted /unsv MS swaged street light pole of 11 mtr heightas specified and |
| 2 | Taking down/ Dismentaling of old cement concrete (PCC) street light pole of 11 mtr heightas specified and directed. |
| 3 | Taking down and refixing of serviceable LED street light fitting 90 Watt 230 V AC outdoor type retrieved from the old unsv street light poles including fixing arrangemnts such as reducer, nut, bolt & washer etccomplete all as specified and directed. |
| 4 | M&L for hot dip Galvanized 6 meters height octagonalpole, 130mm bottom, 70mm top, 3mm section thickness, PCD 200mm with base plate of 200 x 200 x 12mm with anti theft strip in octagonal shape welded window cover. Foundation accessories each set consists of 4 nos of M 20 x 600mm bolts with 10% of templates for total value of poles alongwith 250mm wide strip for antitheft arrangement including 500mmbracket suitable for light mounting arrangement, SP 10Amp MCB with pole mounted seperator including PCC 1:4:8 type D2 using 40 mm & 20mm graded crushed stone in foundation filling and mass concrete of size (700mm X 600mm X 600mm) ,15mm thick rendering (plaster) on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement on expose surface above GL,excavaion for pole foundation, laying of 32 mm nominal dia double wall corrugated HDPE pipe of high quality of suitable length fixed in pole foundation for cable in/outall as specified and directed. |
| 5 | Supply & fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with CCT 5700 - 6500 K and efficiency of the fittings 120 Luman/watt and IP-65, high pressure die cast aluminum hosing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed. |
| 6 | M&L for taking down U/S cable from trench/wall/pole of any height and Supply, laying, jointing, testing and commissioning new XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm x 4.0 Core in trench/ on pole/ in duct complete all as specified and directed. |
| 7 | All as per ser item No 06 above but 16 sqmm x 4.0 Core XLPE insulated aluminium conductor cable. |
| 8 | All as per ser item No 06 above but 10 sqmm x 4.0 Core XLPE insulated aluminium conductor cable. |
| 9 | Excavation in trenches not exe 1.5m depth and not exe 1.5m wide in Soft/loose soil and getting out complete as specified and directed |
| 10 | Supply and spread river sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the punned thick layer of 18cm after ramming. |
| 11 | Supplying laying, brick sub class \"B\" common burnt laid in trenches for cable protection complete all as specified and directed. |
| 12 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm at a level complete all as specified and directed. |
| 13 | Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point complete all as specified and directed. |
| 14 | Supply only in replacement of 1100 volt grade cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connection for street light from FRP junction box to street light of size 3 core 1.5 sqmm complete all as directed. |
| 15 | M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix,rolled and compacted for road patch repair work with PCC complete all as specified and directed. |
| 16 | S&F in replacementof 40 mm nominal dia double wall corrugated HDPE pipe of high quality fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. |
| 17 | S&F in replacement of GI pipe of 40 mm nominal dia light grade with all fittings laid in trenches or under road crossing or fixed to walls/poles with clamps nuts, bolts and washers complete all as specified and directed. |
| 18 | Supply, installation, testing and commissioning factory made (CPRI approved) LT panel, outdoor type, made out of 3.15 mm thick CRCA sheet, powder coated, weather, dust & vermin proof, front and back openable door, with suitable size angle iron frame and locking arrangement including suitable working space inbus bar chamber, cable box chamber with cable alley suitable for 3 phase 4 wire system, 415V, 50 Hz, AC supply, including minimum 1.5 times of main incomer rating aluminium bus bar with PVC sleeves/ tape RYB colours for phases identification, including all bus bar shall be extend upto cable box chamber fixed on fiber insulation for RYB & neutral to all out going cable and fixed on raised PCC platform with PCC 1:2:4, with control wiring with suitable copper wire, cable gland & lugs etc including taking down of old unserviceable panel and comprising the following:- (Loc - Near X Block S/S Gate)(i)MCCB 4 Pole 415 volts AC 50 Hz 160 Amps, 36 kA - 01 No (Incomer)(ii) Digital and programmable multifunction meter with all parameter with suitable capacity of 03 Nos CT\"s - 01 No(iii) LED indication lamp with toggle switch RYB for phase indication- 01 Set of three(iv) MCB TPN 4 Pole 415 volts AC 50 Hz 63 Amps, 16 kA - 04 Nos (Outgoing)(v) Astronomical Timer of 40 Amp with relay protecionNote:- (i) OEM will stand warranty of 02 years for complete design, supply and inspection upto site service support.(ii)All MCCBs shall be adjustable type with thermal magnetic release, Ics = 100% Icu & Icw for 1 sec. |
| 19 | Taking down and refixing paver block / Inter locking tiles of any size including cement mortar bedding(but not baking) as per exitingtiles complete all as specified and directed. |
| 20 | S&F of timelite distribution boards 40A , 3 Pole /230V Astronomical time switch including protection relay, contactor and MCB of suitable capacity including fixing arrangements for distribution boards complete all as directed. |