| 1 | S&Fservo controlled voltage stabilizer for automatic operation, three phase, 50 Hz, naturally oil cooled, indoor unbalanced type, copper wound, digital display type and of capacity 150 KVA with the following specifications :-(a) Input voltage 300V-480V.(b) Output voltage stabilized at 415V ± 1% (Adjustable)(c) Rated frequency 50 Hz(d) No distortion in wave form(e) Response time not to exceed 10 mille seconds(f) Sensitivity ± 1%(g) Rate of correction 8 volt/ second for single phase and 20 volt/ second for phase to phase (h) No load losses less than 0.5%(j) Full load loses less than 2.5%(k) Duty cycle-continuous 24x7(l) Efficiently more than 95%(m) Type of load : 3 phase, unbalanced type(n) Digital display voltmeter/ ampmeter(o) Make : Volina(p) Over load/ short circuit protections(q) High/ low voltage cut off(r) By pass arrangement in case of emergency(s) Single phase sequence change protection |
| 2 | S&F Plates 6mm (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W Gde-E-250 quality \"B\" complete all as specified and directed |
| 3 | S&F rolled mild steel joist, channel, angle or tee sections fixed independently, without connecting plates, ( cut to ordinary lengths i.e. within 20 mm of the length ) etc confirming to Gde Fe-410-W (Gde -E-250) quality \"A\" complete all as specified and directed (for making sliding gate). |
| 4 | S&Flaying cable XLPE insualted screened PVC bedded, gavlvanized steel strip or wire armoredelectric power calbes (heavy duty) 1100 volts grade with standard aluminium conductor of size 185 sqmm 3.5 Core |
| 5 | M&L for excavation in trenches not exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc or shafts, wells, cesspits, manholes, pier holes etc no exc 10sqm on plan and n exc 1.5m in depth and gettign out as directed by Engr- in -charge |
| 6 | Removing excavated material not exc 50m and depositing where directed at a level n exceeding 1.5 m above the starting poing and as directed by Engr-in-charge |
| 7 | M&L for returning, refiling in including spreading, levelling, watering and well ramming in layers no exc 25cm and as directed by Engr-in-charge |
| 8 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 9 | M&L laying of bricks, sub-class \"B\" designation 75 for cable protection and as per directed by Engr-in-Charge |
| 10 | S&F cable jointing kit for 1.1 KV (Earhed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 16 Sqmm to 35 Sqmm |
| 11 | S&F in replacement GI pipe light grade ISI marked of size 100mm bore for cable protection including provision of fitting along GI pipe along wall/ pole/ laid under the road/ floor complete all as specified. |
| 12 | Supply, installing, testing and commissioning LT panel, indoor cubicle type, floor mounted, weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz with front openable with locking arrangement, bottom gland plate with sufficient numbers of circular cable entry holes, complete duly powder coated with 7 tank process mounted on angle iron stand made out of angle iron 50 mm x 50 mm x 6 mm, comprising with following complete all as specified and directed :-(a) Bus bar strip 4 ple and capacity 400 Amps aluminium, be based on 1.5 Amp per Sqmm, coloured with plastic coated insulated and sleaves in fourcolours (Red, yellow, blue and black) fixed on procelain insulators with necessary nuts and bolts and wahsers etc.(ii) INCOMING : -(a) Onload changeover switch 320 Amps, 4 pole-01 No(b) MCCB 320 Amp, 415 V, 36 KA, 4 pole, adjustable thermal & fixed magnetic type -01 No.(c) Indicator with LED lamps for RYB -01 set(d) DG/Main ON indicator - 01 Set(e) Digital Ammeter (0-400) Amps(f) Digital Voltmeter (0-500) Volts(iii) OUTGOING:-(a) MCCB 250 Amp, 415 V, 25 KA, 4 pole, adjustable thermal & fixed magnetic type -02 Nos.(b) MCCB 160 Amp, 415 V, 25 KA, 4 pole, adjustable thermal & fixed magnetic type -01 No(c) MCB TPN 32 Amp, 415V, 10 KA-02 Nos |
| 13 | M&L for earthing complete with & including galvanized MS earth plate of size600 x 600 x 6mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steel all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and connected to panel board, all as specified and testing on completion including provision of earth wire 4mm dia duly protected with and including 15mm dia bore light grade GI pipe upto 7.5m from electrode to earth point including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate andGI medium grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete (1:2:4) type B-1 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c both ways with suitable handle for lifting & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed.Note: On testing, after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department. |
| 14 | M&L for point wiring for one light point controlled by one switch with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing surface/ concealed conduit and accessories andterminated in andincluding new sunk type pressed steel terminal switch boxes 1.6mm thick with plastic laminated bakelite sheet top cover 3mm thick fixed with nickel polished brass screws with washers and including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed. |
| 15 | Ditto all as per srl item No. 14.00 above, but with 2.5 Sqmm (nominal area) FRLS cable for one 3 pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed. |
| 16 | S&F ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified and directed. |
| 17 | S&F in replacement white modular switch 1 way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed. |
| 18 | S&F in replacement white modular switch 1 way 16 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed. |
| 19 | S&F in replacement white modular socket6/16 Amp, 250 V ACtwin socket combined two module including taking down existing socket complete all as specified and directed. |
| 20 | S&F in replacement white modular fan regulator , 250 V AC step type 5 stepsone module including taking down existing fan regulator complete all as specified and directed. |
| 21 | S&F LED lights fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 22 | M&L for sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed.Note: Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire through rigid PVC conduit shall be measured as one RM. |
| 23 | S&F sheet metal enclosure for DBs when MCBs to be used, SPN 4 ways 240 V, with 200 Amps rated bus bar, double door all as specified |
| 24 | S&FIsolator upt 40 Amps, SP 240V, complete all as specified and as directed. |
| 25 | S&FIsolator upt 40 Amps, SPN 240V, complete all as specified and as directed. |
| 26 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 27 | Supply & fixing steel body exhaust fan, 300/380 mm sweep, 900 rpm, single phase, 23 volt, heavy duty, with lowered shutter including provision of three core flexible cable of required length of size 23/.0076 from ceiling rose/ connector to fan terminal,fixing the fan on wall with suitable size of nut, bolt & washer, including making the hole in wall incl necessary civil/ plastering work to match the disturbed surface including taking down to existing exhaust fan and depositing to MES store complete all as specified and directed by Engineer-in-Charge. |
| 28 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed |
| 29 | Excavation in trenches in soft /loose soil, not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan andgetting out complete all as specified and directed. |
| 30 | Ditto all as per srl item No. 29 above, but exc 1.5m in depth but not exceeding 3.00 M depth complete. |
| 31 | M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete etc complete all as specified and directed. |
| 32 | M&L reinforced cement concrete nominal mix in (1:2:4) type B-1 ( using 20mm crushed stone aggregate) as in foundation, rafts, footings, foundation beams, plinth beams, bases for coloumns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 33 | Returning, filling in including leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and directed. |
| 34 | Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 35 | M&Lfor soil filling in floors or pavings laid in layers n.exc 15cm thick, spread, levelled, and blinded with earth and rammed including watering complete all as specified and directed |
| 36 | M&L for MS TMT bars 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 37 | S&FTMT bards 6 to 8 mm dia and voer cut to length, bent to shape as reqd incl cranking, bending, hooking ends and bidnding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specifed |
| 38 | M&Lfor use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, for rough finished concrete surfaces completeall as specifiedand directed. |
| 39 | M&L reinforced cement concrete nominal mix in (1:2:4) type B-1 ( using 20mm crushed stone aggregate) as in foundation, rafts, footings, foundation beams, plinth beams, bases for coloumns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 40 | M&L for formwork to sides of pillars, posts, stuts piers, columns and stanchions colum up to roof level |
| 41 | Formwork to soffits of suspended slabs such as roof slabs, floor landing and similar works not exceeding 200mm thick finished rough complete all as specified. |
| 42 | Formwork to soffits of floor or roof beams, hamrching, cantilever, lintels complete all as specified and as directed. |
| 43 | M&L for RCC 1:2:4 type B1 using 20mm graded aggregates for Lintel Beam, Chajja and Rampcomplete all as specified and as directed. |
| 44 | M&L for RCC 1:2:4 type B1 using 20mm graded aggregates for roof Beam |
| 45 | M&L for formwork to sofftis of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick all as specified and as directed. |
| 46 | M&L for RCC 1:2:4 type B1 using 20mm graded aggregates for in slabs supported on walls, beams and columns in sloors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 47 | M&L for brick work with subclass \" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) all as directed and specified. |
| 48 | M&L for brick work with sub class B bricks, strainght or curved on plan to any radius in half brick thick walls, built in CM 1:4, complete all as specified and as directed. |
| 49 | M&L for 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 50 | M&L for 12mm thick cement plaster in cement mortar (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified |
| 51 | M&L forrendering 5mm thick in MC 1:3 to celling and sofits etc RCC work all as specified and as directed. |
| 52 | M&Lfor waterproofing compound @3% weight of cement of external surface all as specifed and as directed. |
| 53 | M&L for 20-25mm thick machine cut Kota stone slab 600mm x 600mm size flooring, jointed with grey cement mixed with pigment to match the shade of the slab including grinding, rubbing and polishing to mirror finish with & including screed bed or bedding layer of mortar 15mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed |
| 54 | Ditto all as per item No 53.00 above, but as in skirting laid over and including 10mm thick rendering in cement mortar (1:4) as backing coat. |
| 55 | M&L for cement concrete (1:5:10) type E-2 using 40mm graded brick aggregate as in filling in sunken portion and mass concrete complete all as specified and directed. |
| 56 | M&L for 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 57 | M&L for one coat of bitumen primer for use in waterproofing and damp proofing treatments @ 0.3 Ltr/ Sqm on roof top |
| 58 | M&L for APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt. not less than 150 gms/ sqm) laid on primed surface by forced application complete all as specified and directed. |
| 59 | M&L for integral waterproofing compound @ 3% weight of cement, complete all as specified and as directed. |
| 60 | M&L 25cm x 25cm x 22mm thick chequeredcement concrete coloured tiles with grey cement and pigment, jointed and pointed in neat cement slurry in floor laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed. |
| 61 | M&L preparation of newly plastered or un-plastered surface of walls including cornices, plasters etc. and applying two coats of cement base paint complete all as specified and directed. |
| 62 | M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 63 | M&L for preparation of new plastered surface of wall and applying three coats of white washing complete all as specified and directed. |
| 64 | M&L for hard core of broken stone or boulder of gauge n. exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed. |
| 65 | M&L for 50mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection/ path including finishing the concrete surface even & smooth without using extra cement complete all as specified & directed. |
| 66 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth courses, roof kerbs or mud stops, benching, coping, bed plates, parapets, water through and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed |
| 67 | M&L for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including taking down old unserviceable steel window complete all as specified and directed |
| 68 | M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed. |
| 69 | M&L for galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed. |
| 70 | S&F mild steel framed work for such as guard bars/ grills, grating etc with end of bars shouldered and/ or riveted forged into spikes, framed guard bars barred iron door, railings and similar work complete conforming to Fe-290 Gde E 165 including one shop coat of zinc chromate primer complete all as specified and directed. |
| 71 | S&F for steel rolling shutters 1mm thick, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete push pull or manual type complete all as specified and directed. |
| 72 | M&L for preparation of new wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 73 | Plates 6mm (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W Gde-E-250 quality \"B\" complete all as specified and directed |