| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | PCC 1.6.12 WITH CEMENT ,F.SAND & 40 MM B/BALLAST INCLUDING ALL |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | same as item No. 5 But in slab as per DSR 2023 ITEM NO-5.3. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 8 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. |
| 9 | First class brick work in 1:4 with cemnt,c.sand including all |
| 10 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 11 | Laying of 25 mm thick KOTA stone of size 45 x 45 cm and above flooring over prepared base with 2cm thick 1:3 cement ,c.sand mortar including filling of joints including all as per dsr new item no-1 |
| 12 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) mm |
| 13 | Providing & fixing Granite stone of 0.50 sqm any colour above flooring over prepared base with 2cm thick 1:4 cement ,c.sand mortar including filling of joints including all as per dsr new item no-1 |
| 14 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 15 | Providing 3.5 mm thick 2.2 cm deep glass strip in the joint of floor |
| 16 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) |
| 17 | 12 mm cement plaster finished with a floating coat of neat cement of mix :-1:6 (1 cement: 6 coarse sand) |
| 18 | 15 mm cement plaster on rough side of single or half brick wall of mix:-1:6 (1 cement: 6 coarse sand) |
| 19 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 23 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 24 | S/F of 10 cm. dia P.V.C.down Pipe (kissan,supreme or equivalent) 6kg/sq. cm. ……….Comp.as per SOR SI No.730B |
| 25 | S/F OF INFORMATERY SIGN BOARD/ INNAUGARATION STONE |
| 26 | S/F of C.P.V.C. Pipe 100mm dia including all complete. |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 28 | CPVC PIPE 20 mm nominal dia Pipes |
| 29 | CPVC PIPE 15 mm nominal dia Pipes |
| 30 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 31 | S/F of full way gate valve all complete of work. |
| 32 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 33 | P/F of C.P. brass bib cock of 15mm dia nominal bore…….. including all complete of work.as per DSR 18.49.1. |
| 34 | P/F of C.P. brass long body bib cock of 15mm dia nominal bore…….. including all complete of work.as per DSR 18.51.1. |
| 35 | S/F of 32 MM WASTE PIPE. FLEXIBILE |
| 36 | Providing & fixing miror superior glass rectangular shape. |
| 37 | P/F of C.P. brass Stop cock of 15mm dia nominal bore…….. including all complete of work.as per DSR 18.52.1. |
| 38 | P/F of Sumersible 200 fit bore with moter and pannel fiting including all complete of work.as per SOR |
| 39 | Wiring point for light 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire,inside the conduit using moduler board & moduler switch complete . (a) Light Points 1.8.1 |
| 40 | (c) 5Amp. Plug |
| 41 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. |
| 42 | S&F of 5 Amp to 32 Amp. 240/415 VOLT 10KA SPMCB |
| 43 | Supply and fixing of 15 WATT LED DOWN light reces /surface/pendent mounting round with heat sink, diffuser/ Reeflector with driver set complete in all respect.(1402 CAT AAA) Please Enable Macros to View BoQ information |