| 1 | Taking down carefully copper/aluminium point wiring from woodenbattan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including fittings (such as switches, ceiling roses, pendants, regulator, sockets etc) and making good disturbed surfaces of walls, floor etc complete all as directed by EIC. |
| 2 | Taking down old DBs includingexisting MCCBs, MCB TPN, SPN, SP and connected items of any make and type from the site and making good surface complete all as specified and directed. |
| 3 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 4 | Taking down old LED fitting,Security light, bulb of any size and make from the site and making good surface complete all as specified and directed. |
| 5 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and its also including various sizes of module plates in gray/white colour or hylam sheet (as required at site) also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly complete all as specified and as directed. |
| 6 | One light/fan point controlled by one way switch |
| 7 | One Socket Outlet on same board |
| 8 | One light point controlled by two way switch |
| 9 | One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. |
| 10 | -ditto- as above item No 5.04 but copper conductor 2.5 sqmm for 15 amp socket outlet. |
| 11 | M & L for power point with insulated stranded copper conductor cable 4 Sqmm single coretwo run and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to earth dolly complete (socket and switches to be measured and paid separately) |
| 12 | S & F in replacement incl making existing surface good sheet metal enclosures with socket plug top and MCB\"s with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp.(AC Box) complete all as directed by EIC. |
| 13 | S & F in replacement of modular switch single pole one way 6 Amps, 1 module ISI marked complete all as specified and directed by EIC. |
| 14 | S & F in replacement of modular socket single pole one way 6 Amp-2/3 pin, 2 module ISI marked complete all as specified and directed by EIC. |
| 15 | S & F in replacement of modular switch single pole one way 16 Amps, 1 module ISI marked complete all as specified and directed by EIC. |
| 16 | S & F in replacement of modular socket single pole one way 16 Amp-2/3 PIN, 2module ISI marked complete all as specified and directed by EIC. |
| 17 | S & F of modular switch socket combination 16A (with gang box where is required), 6 pin, 3 module, ISI marked complete all as directed by EIC. |
| 18 | S & F in replacement of modular bell push 6A, 1 module ISI marked complete all as specified and directed by EIC. |
| 19 | S & F in replacementWhite cover plate with frame, 3 module ISI marked complete all as directed by EIC |
| 20 | S & F in replacement White cover plate with frame, 6 module ISI marked complete all as directed by EIC |
| 21 | S & F in replacementWhite cover plate with frame, 12 module ISI marked complete all as directed by EIC |
| 22 | S & F in replacement of call bell multi music/Ding Dong ISI marked complete all as specified and directed by EIC. |
| 23 | S & F in replacement of bell push flush type SP 5 Amp complete all as specified and directed by EIC. |
| 24 | S & F wireless door bell kit , over 1000 feet range 60 chime, 5 levels volume, IP44 waterproof , 220 V, and LED flash with ISI marked complete all as specified and directed by EIC. |
| 25 | S & F in replacement of switch piano type single pole one way 5 Amps, ISI marked complete all as directed by EIC. |
| 26 | S & F in replacement of socket outlet 5 pin flush 6 Amp multi pin 2/3 pin complete all as directed by EIC. |
| 27 | S & F in replacement of switch socket combined outlet 6 pin flush 16 Amp multi, ISI marked complete all as directed by EIC. |
| 28 | S & F in replacement ofswitch piano type/flush button type single pole two way 5 Amps front operated ISI marked complete all as directed by EIC. |
| 29 | S & F in repair of ceiling fan regulator stepped type 2 Module ISI marked, complete all as specified and directedby EIC |
| 30 | S & F in replacement of angle holder , PVC/Poly carbonate type withback plate suitable for batten fittings complete all as directed by EIC. |
| 31 | S & F in replacement of3 pin plug top AC-230V, 6 Amp complete all as directed by EIC. |
| 32 | S & F in replacement of3 pin plug top AC-230V, 16 Amp complete all as directed by EIC. |
| 33 | S&F in repair ceiling rose, 3 terminal/PVC/Polycarbonate, isolated body complete all as specified and directed by Engr-in- charge. |
| 34 | S & F in replacement of High lam sheet cover ISI markedwith required Nos of space for switches/ Sockets/ Regulator of size 250x280mm complete all as directed by EIC. |
| 35 | S & F in replacement of LED bulb & supply and fix inverter type LED bulb 12 watt with very high efficiency suited for installation in existing lamp holders, complete all as as directed by EIC. |
| 36 | S & F in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics,mutlti colour LED flood light with cast aluminium housing, toughened glass cover, high efficient LED and wired with all accessories and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,complete all as as specified and directed by EIC. |
| 37 | S & F in replacement LED batten luminaire surface/wall mounted ,4 feet 20 Watts comprise of aluminium extruded with anodisedwith powder coated in white colour with decorative plastic end cap. The luminare is pre-wired with high efficiency electronic driver,with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-40 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker freeandincluding connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings completeallas specified and directed by EIC. |
| 38 | S & F in replacement LED batten luminaire surface/wall mounted, 2 feet 10 Watts comprise of aluminium extruded with anodisedthermally conductive material with powder coated in white colour with decorative plastic end cap. The luminare is pre wired with high efficacy electronic driver,with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker freeandincluding connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings completeallas specified and directed by EIC. |
| 39 | S & Fin replacement Recess/ceiling mounting as suitable in existing fitting ultra slim 36 W LED 2x2 edge-lit tile in Aluminium Extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as specified and directed. |
| 40 | S&F in replacement of new genration post top lanterns, IP-66elegantly designed spun alumnium and high grade aluminium heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. MSbase provided to support the housing, environmental friendly long life high power LED light 25 watt complete all as directed by EIC . |
| 41 | S & F in replacement 12 W, 15W, 18W LED Recess/ceiling mounted downlighter (squrae/round shape) with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver complete all as directed by EIC. |
| 42 | S & F LED Bollard light 9 watt, with aluminium die cast housing and polymer diffuser, 765 lm, lunaire efficacy 85 lm/W, CRI>70, burning hour 50000 hr, class-1, operating voltage 140V to 270V AC, 50 Hz, PF>0.9, THD<15%, surge protection 4kV, IP 66 protection, wired with inbuilt driver complete all as specified and directed by EIC. |
| 43 | M & L for servicing, testing and commissioning of 2 Hp electric motor for holding and smoothoperation of curtains complete with proper mounting arrangement of pully/rolling mechanism with suitable size of new GI wire for curtain holding and support. The motor shall ensure smooth operation witout jerk including all necessary electrical connection, safety arrangement complete all as specified and directed by EIC. Note: Contractor should make its own arrangement for working at 40 ft height. |
| 44 | M & L Submain wiring with three run single core 10 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in concealedNew PVC conduit 25 mm dia ISI marked alongwith one run of 10 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.Note:- Three runs of 10 sqmmcable and one run of PVC conduit/casing capping shall be measured as one RM. |
| 45 | M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated multi stranded, unsheathed, 1100volts grade in concealedNew PVC conduit/casing 25 mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.Note: Three runs of 6 sqmmcable and one run of PVC conduit/casing capping shall be measured as one RM. |
| 46 | M & L for sub main wiring with two run of 4 sqmm size FRLS PVC insulated multi stranded copper conductor fire retardant cable(Nominal area) and one run of4 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing cappingof required size complete all as directed by EIC. Note: Three runs of 4 sqmmcable and one run of PVC conduit/casing capping shall be measured as one RM. |
| 47 | M & L for sub main wiring with two run of 2.5 sqmm size PVC insulated multi stranded copper conductor fire retardant cable(Nominal area) and one run of2.5 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing cappingof required size complete all as directed by EIC. Note: Three runs of 2.5 sqmmcable and one run of PVC conduit/casing capping shall be measured as one RM. |
| 48 | M & L forPVC insulated aluminium service cable un-armoured 2.5 sqmm 3 core with ISI marked complete all as specified and directed by EIC. |
| 49 | S&F in repair of Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors along with suitable insulator above groundcomplete all as specified and directed |
| 50 | S&F in repair of air termination, single pointed, Copper rod 12 mm dia and 300 mm longcomplete all as specified and directed. |
| 51 | M&L for Test point terminal block made of gun metal or phosphorus bronze Size 75 x 75 x 25mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screwcomplete all as specified and directed. |
| 52 | M&L for HDPE pipe of 32 mm dia, cut to Size all as required at Size including fixing arrangements and providing appropriate Size insulators to insulate pipe from foundation or air termination from pipecomplete all as specified and directed. |
| 53 | M&L for clamps, bracings, supports and back plates made out of structrural steel sections including nuts, bolts and washers all as required at size for fixing GI tubing in truly vertical position including two coats of synthetic enamel paint over a coat of red oxidecomplete all as specified and directed. |
| 54 | M&L for plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work with two coat of lime wash wherever applicable, complete all as specified and directed |
| 55 | M & L Chemical earthing as per ASHLOK make model T-39, copper coated safe earthing electrode (SEE) of 3 mtr length with inner pipe of 40 mm dia and outer pipe of 80 mm dia with min 80-100 micron coation, filled with black fill compound mixed with soil and high specific gravity crystallin conductive mixture (CCM) of grade \"B\"filled inside the earth electrode including drilling of hole of 150 mm dia bore with boaring machine upto 20 mtrs depth in soft/hard rock and filling the bore hole with black cotton soil upto 17 mtrs level i.e below the electrode bottom level including PCC earthpit and copper strip of 32 x 6 mm with GI tubing light grade for protection upto 7.5 mtr complete all as specified and directed by EIC. |
| 56 | M & L for fixing of distribution box cover made up of GI steel Sheet with a CRCA door, cutting , two coat painting, screw, nuts etc including all connected items as required at site, suitable for various size ofVTPN DB, TPN DB, SPN DB complete all as specified and directed by EIC. |
| 57 | S&F sheet metal enclosure for VT DB TPN, MCCB DB TPN 4 way, with 200 A rated bus bar, double door with 100 Amp, 25 KA, 4P MCCB (Ics=100% Icu) as incomer (Vertical type double door,100 Amps MCCB rate inclusive) 150 Amp rated bus-bar and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box with provision for 4 Pole MCCB* as incomer and SP/TP MCB\"s as outgoingscomplete all as specified and directed. |
| 58 | S & F in replacement distribution board SPN 8 way with 200 Amp rated bus bar double door, IP 43 protection complete all as directed by EIC. |
| 59 | S & F in replacement distribution board SPN 12 way with 200 Amp rated bus bar double door, IP 43 protection complete all as directed by EIC. |
| 60 | S & F in replacement amp rating 240V 10 KA\"B\" curve MCB SPN 32-40 A current currying capacity in the MCB DB with suitable thimbles complete all as specified and directed by EIC |
| 61 | S & F in replacement of MCB TPN 40 to 63 Amps, 415 V with thimble suitable for existing/new wires in DBs complete all as directed by EIC. |
| 62 | S & F in replacement amp rating 240V 10 KA\"B\" curve MCB SP 6-32 Amp current currying capacity in the MCB DB complete with suitable thimble, connection testing and commissioing complete all as specified and directed by EIC. |
| 63 | S & F in replacement 100 A MCCB 4 pole, 16 kA breaking capacity, 415 V (Ics=100% Icu ) with suitable thimbles all as specified and directed by EIC |
| 64 | S & F in replacement 63 A MCCB 4 pole, 16 kA breaking capacity, 415 V (Ics=100% Icu ) with suitable thimbles all as specified and directed by EIC |
| 65 | M&L earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to galvanised earth lead wire 4 mm dialead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt with precast chamber PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15 mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. |
| 66 | Supply installation, testing and commissioning of Software Support and Sim Charges including software hosting, software AMC, GPRS Charges, RF network monitoring and troubleshooting and repair/replacement of meter/DCU with manufacturing defect for 136 meters in officers area complete all as specified and directed by EIC.NOTE:-Contractor should sign the MoU with OEM for AMC |
| 67 | S & F in replacementincl taking down of single phase AMR meter compatible with existing AMR meterLCD Display type in poly carbonate or sheet steel body ,class-I ,ISI marked, including anti tamper features,communication port ,50 HZ,240 Volts AC ,single Phase rating,10 Amp complete all as specified and directed by Engr-in-charge. Note:Contractor should sign the MoU with OEM for compatibility with existing AMR meter. |
| 68 | Supply and replacement incl taking down of electronic energy meter LCD Display type in poly carbonate or sheet steel body ,class-I ,ISI marked, including anti tamper features,communication port ,50 HZ,240 Volts AC ,single Phase rating,5 Ato 30 Amp complete all as specified and directed by Engr-in-charge. Make L&T /Anchor/Havells/HPL.Note: old U/s electric meter deposite to E/M storeyard. |
| 69 | Supply and replacementincl taking down of electronic energy meter LCD Display type in poly carbonate or sheet steel body ,class-I ,ISI marked, including anti tamper features,communication port ,50 HZ, 415 Volts AC ,single Phase rating,10 Ato 60 Amp complete all as specified and directed by Engr-in-charge. Make L&T /Anchor/Havells/HPL.Note: old U/s electric meter deposite to E/M storeyard. |
| 70 | Supply and replacementincl taking down of CT meter (electronic energy meter) LCD Display type in poly carbonate or sheet steel body ,class-I ,ISI marked, including anti tamper features,communication port ,50 HZ, 415 Volts AC ,single Phase rating,10 Ato 60 Amp complete all as specified and directed by Engr-in-charge. Make L&T /Anchor/Havells/HPL.Note: old U/s electric meter deposite to E/M storeyard. |