| 1 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Havells/ Halonix/USHA /Crompton or eq make |
| 2 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 3 | Providing/ fixing of 16 Amp switches socket (Make: Legrand, Hager, L&T, ABB, Havells or eq) combined Box/recess type |
| 4 | Wiring for Computer point with 1.5 sq.mm(Make: Finolex, Polycab or eq) with 1.5 sq.mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit (D plast/Tiger/Anchor make ), with modular switch with two sockets (Make: Legrand, Hager, L&T, ABB or Havells), modular plate, suitable GI box etc. from DB as required.Note: Rate of suitable conduit/channel and wall cutting and finishing is included in the above description. |
| 5 | Wiring for Heating point with 4 sq.mm(Make: Finolex, Polycab or eq) with earth wire (4 sq.mm) FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit (D plast/Tiger/Anchor make ), with modular 15 A switch with 15 A sockets (Make: Legrand, Hager, L&T, ABB or Havells), modular plate, suitable GI box etc. from DB as required.Note: Rate of suitable conduit/channel and wall cutting and finishing is included in the above description. |
| 6 | Group B Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm(Make: Finolex, Polycab or eq) FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit (D plast/Tiger/Anchor make ), with modular switch (Make: Legrand, Hager, L&T, ABB or Havells), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Note: Rate of suitable conduit/channel is included in the above description. |
| 7 | Supplying and laying of 2 core, armoured aluminium, XLPE or rubber insulated 10 sq.mm LT cable in surface/ recessed/ ground etc as required at site as directed by EIC (Make: havells, Finolex, Polycab or eq) |
| 8 | Providing and fixing of 63 A, 4P Manual Changeover in sheet steel enclosure of approved make (Generator) |
| 9 | Supplying and fixing 3 pin, 5 A ceiling rose on junction box/ wooden block including connections etc. as required ISI Marked Superior Quality |
| 10 | Supplying and laying (depth 2 feet below ground) of following size ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. (Make: havells, Finolex, Polycab or eq)3.5 X 35 sq. mm |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ including recessed medium class PVC conduit (Make: Finolex, Polycab or eq)2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (D plast/Tiger/Anchor make )Note: Rate of suitable conduit/ channel and wall cutting and finishing is included in the above description25 mm |
| 13 | Earthing with G.I. earth ROD/ plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 14 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. but bolt & spring washer spaced at 50mm) |
| 15 | Supplying and fixing of 15 watt square/ round, recess/ surface mount LED down lights with high efficient LED\"s and glare free opal/ diffusers, commertial lights minimum 100lm/W(Make: Havells, Wipro, Halonix or eq) |
| 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board (of approved make), 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) of make Hager, Legrand, ABB, SiemensNote: Rate of suitable conduit/ channel and wall cutting and finishing is included in the above description 8 way , Double door(UPS, CP, Lights) |
| 17 | Supplying and fixing , 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker/ RCCB/Voltage and current protection (of approved make)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Legrand, Hager, ABB, Siemens |
| 18 | 6-32 A Single pole MCB |
| 19 | 40 A Double Pole MCB |
| 20 | 63A Double Pole MCB |
| 21 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required ISO 9001 Certified, CE Approved, Applicable BIS Standards of make Hager, Legrand, ABB, Siemens4 way (4 + 12), Double door |
| 22 | (DSR 2.15.3) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity urrent 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 23 | Providing & Fixing of 63 amps microprocessor based MCCB TPN, 4pole 16KA, along with all accessories for HVTPNs confirming to BIS standards with ISI mark alongwith metal enclosure Make: Legrand, Hager, ABB, Siemens |
| 24 | Providing and fixing of 63 Amp, 10kA, C-Curve D/P MCB along with enclosure of required size.Make: Legrand, Hager, ABB, Siemens |
| 25 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5 X 35 sq. mm |
| 26 | Providing and Fixing of lighting fixture pressure die-cast aluminium IP66 roadway/ flood light type luminaries with high power LED(100-120W) (of make Havells, Philips or eq) with toughened glass 110 Lm/W |
| 27 | Supply, installation, testing & commissioning of minimum 1375VA 12V Pure Sine Wave inverter with 1x180AH 12V tubuler Battery of make Exide or eq. including suitable rack/trolley, input/output leads/Switch sockets etc. to make the system operational. |
| 28 | Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire (Make: Finolex, Polycab or eq) through 1 inch heavy duty PVC conduit pipe (D plast/Tiger/Anchor make ) and providing and fixing of 32 Amp DP MCB C curve (Make: Legrand, Hager, ABB, Siemens), with BOX point taken up to D.B. duly tested and commissioned in all respects complete.Note: Cost of 1 inch heavy duty conduit is included all items included like wire, box, switches etc. Please Enable Macros to View BoQ information |
| 29 | Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire (Make: Finolex, Polycab or eq) through 1 inch heavy duty PVC conduit pipe (D plast/Tiger/Anchor make ) and providing and fixing of 32 Amp DP MCB C curve (Make: Legrand, Hager, ABB, Siemens), with BOX point taken up to D.B. duly tested and commissioned in all respects complete.Note: Cost of 1 inch heavy duty conduit is included all items included like wire, box, switches etc. Please Enable Macros to View BoQ information |