| 1 | Earth work in excavation by manual means for path way, toilet block,septic tank and soak pit foundation over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge |
| 2 | Providing and laying in position cement concrete for portable toilet block of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Providing Coursed rubble masonry for portable toilet block with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 4 | Reinforced cement concrete work at plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement for portable toilet block 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and Medium Tensile steel bars |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for plinth beam for portable toilet block |
| 7 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 8 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% per litre |
| 9 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge |
| 10 | \"Supplying fitting, fixing, of MS Portable toilet cabin of size 16\"X8\"X8.5\" attached EWC 3 with wash basin. As per specifications below 1. Bottom Frame: Made of 150x50mm formed MS C channel of 3mm thick. 2. 100X50C Channel, 80x40mm & 50x50mm square pipes.16guage 3. Top Frame: Frame made of 50x50mm square pipes.18guage. 4. Stiffener Top: 50x25mm, 25x25mm Square pipes.18Guage. 5. Side Wall Stiffeners: Corner post shall be of 50x50mm Square pipes & wall thickness of 50mm. 18guage. 6. Paneling Outside: Specially corrugated 1`.2mm thick sheet welded on MS frame19guage. 7. Internal Wall Paneling: The paneling of side walls and roof shall be of 8mm thick Prelaminated MDF board & all vertically and horizontal corners shall be neatly & smoothly finished with Aluminum sections 8. Roof Outside:1.2mmthick MS sheet properly sloped & watertight.18guage. 9On the bottom frame 18mm thick Bison panel/18mm commercial Ply i.e. Cemented bonded fiber sheets shall be fixed by means of self- taping screw & 2mm thick PVC vinyl Carpet shall be fixed on the panel. (100% water, termite & dimensional proof with vinyl Carpet).. 11. Main Door: The door shall be of external opening type made out of the same material as wall panels &canopy above the door. Frame work by tubular pipe of 25x25mm & the door interior shall be finished with same material matching with that of The Cabin interior. Door with std hardware locks & handIes. 12. Insulation: Glass wool density of 32kg/m3 (25mm) with insulation for top & side walls. 13. All wiring shall be concealed and shall be PVC insulated copper wires of ISI quality, suitable for 240-volt, 50 HZ single phase AC power supply. 2.5 mm thick cable for lighting, switches with 3pin Sockets, bulk head light above the door, 4mm thick cable for main electrical supply & with MCB protection. 14. Outside Painting: All components painted with one coat of primer and two coats of corrosion-free synthetic epoxy paint. 15. Hooks: Specially formed for easy lifting and shifting.\" |
| 11 | Plumbing line from borewell to portable toilet block and sanitation line from portable toilet block to septic tank including cost of labours, material, supplying, fitting, fixing in position, transportation, etc complete as per direction of site in charge |
| 12 | PVC manhole cover of 600mm X 600mm for septic tank and soak pit including suppling, fitting, fixing and transportation etc |
| 13 | Providing the fresh lime concrete for path way using 20 mm down size brick bhats with 1:2 ratio of including proper slope, fine finishing including curing etc complete |
| 14 | Supplying, fitting, fixing of burnt granite stone slab of 0.6mX0.9mX0.1m thick in pathway , stone cutting should be in line , length , Two line dressing to granite stone slabs should have proper line, level surface fixing it in position in lime mortar bed of 7.5 cm 1:3 ( 1 lime 3 sand) and filling the joints with lime mortar 1:3 , etc. as per direction of engineer in charge |
| 15 | Sinking of Borewell of 165mm dia upto 180m deep clear using super-fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) |
| 16 | Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work for 10.00 HP - 245 LPM @ 112 m = 8 STG Outlet Dia – 2.5’’ |
| 17 | supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554- 1985 one end fixed with socket conforming to IS 4270- 2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty |
| 18 | Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete... NOTE: Upto 65 mm dia Heavy duty G.I Pipe is used. |
| 19 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross-sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments as per direction of site incharge |
| 20 | Indoor panel box including all accessories, Outdoor panel box including accessories, towards cost of special for installing submersible pump set (GI accessories like coupling, non-return value etc..) and Towards cost of installation charges of submersible pump set and connect with pipeline |